Whole-body three-dimensional MR angiography with a rolling table platform:: Initial clinical experience

被引:85
作者
Goyen, M
Quick, HH
Debatin, JF
Ladd, ME
Barkhausen, J
Herborn, CU
Bosk, S
Kuehl, H
Schlepütz, M
Ruehm, SG
机构
[1] Univ Hosp Essen, Dept Diagnost & Interventional, D-45122 Essen, Germany
[2] Siemens Med Syst Inc, Erlangen, Germany
关键词
angiography; technology; arteries; extremities; MR; stenosis or obstruction; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiol.2241011345
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A technique for performing whole-body magnetic resonance (MR) angiography with multistation three-dimensional MR angiography by using a self-developed rolling table platform that integrates the surface coil was evaluated in three volunteers and 10 patients. Use of the surface coil resulted in high signal-to-noise and contrast-to-noise ratios, which translated into sensitivity and specificity of 95.3% and 95.2%, respectively, for detection of significant stenoses (luminal narrowing, >50%) in lower extremity peripheral vascular disease. (C) RSNA, 2002.
引用
收藏
页码:270 / 277
页数:8
相关论文
共 17 条
[1]  
*AM HEART ASS, 1997, 1997 HEART STROK STA
[2]   MR-ANGIOGRAPHY VERSUS CONVENTIONAL X-RAY ANGIOGRAPHY IN THE LOWER-EXTREMITIES - EVERYONE WINS [J].
BORRELLO, JA .
RADIOLOGY, 1993, 187 (03) :615-617
[3]   Gadolinium chelates with weak binding to serum proteins - A new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging [J].
Cavagna, FM ;
Maggioni, F ;
Castelli, PM ;
Dapra, M ;
Imperatori, LG ;
Lorusso, V ;
Jenkins, BG .
INVESTIGATIVE RADIOLOGY, 1997, 32 (12) :780-796
[4]   Gadolinium-enhanced three-dimensional MR angiography of the aorta and peripheral arteries: Evaluation of a multistation examination using two gadopentetate dimeglumine infusions [J].
Earls, JP ;
Patel, NH ;
Smith, PA ;
DeSena, S ;
Meissner, MH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) :599-604
[5]   Relation between arteriosclerosis in the coronary and renal arteries [J].
Gross, CM ;
Kramer, J ;
Waigand, J ;
Luft, FC ;
Dietz, R .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (11) :1478-1481
[6]   Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography [J].
Ho, KYJAM ;
Leiner, T ;
de Haan, MW ;
Kessels, AGH ;
Kitslaar, PJEHM ;
van Engelshoven, JMA .
RADIOLOGY, 1998, 206 (03) :683-692
[7]   Diabetes and peripheral arterial occlusive disease:: Prospective comparison of contrast-enhanced three-dimensional MR angiography with conventional digital subtraction angiography [J].
Kreitner, KF ;
Kalden, P ;
Neufang, A ;
Düber, C ;
Krummenauer, F ;
Küstner, E ;
Laub, G ;
Thelen, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (01) :171-179
[8]   Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: Preliminary experience [J].
Meaney, JFM ;
Ridgway, JP ;
Chakraverty, S ;
Robertson, I ;
Kessel, D ;
Radjenovic, A ;
Kouwenhoven, M ;
Kassner, A ;
Smith, MA .
RADIOLOGY, 1999, 211 (01) :59-67
[9]   BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
CHENEVERT, TL ;
WILLIAMS, DM ;
MARX, V ;
CHO, KJ .
RADIOLOGY, 1995, 197 (03) :785-792
[10]   Hemodynamically significant atherosclerotic renal artery stenosis: MR angiographic features [J].
Prince, MR ;
Schoenberg, SO ;
Ward, JS ;
Londy, FJ ;
Wakefield, TW ;
Stanley, JC .
RADIOLOGY, 1997, 205 (01) :128-136