Sodium management in dialysis by conductivity

被引:38
作者
Bosetto, A
Bene, B
Petitclerc, T
机构
[1] Hosp Dasco SPA, Medulla, Italy
[2] Hop La Pitie Salpetriere, Paris, France
[3] Hosp R&D, Lyon, France
来源
ADVANCES IN RENAL REPLACEMENT THERAPY | 1999年 / 6卷 / 03期
关键词
water-electrolyte balance; electric conductivity; clearance; biofeedback; hemodialysis;
D O I
10.1016/S1073-4449(99)70020-8
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The determination of dialysate sodium concentration is one of the challenges of dialysis prescription, because no accurate information on the predialytic sodium overload is available. Too low dialysate sodium is responsible for intradialytic intolerance symptoms, whereas too high sodium may lead to long-term water sodium overload with cardiovascular hazards (hypertension, left heart failure). We propose here a biofeedback system based on noninvasive repeated measures of ionic dialysance and plasma water conductivity used here as a surrogate of plasma water sodium. This system achieves a stable postdialytic sodium pool and subsequently a dialysate sodium concentration adapted to the inter dialytic sodium load. This new tool in dialysate sodium prescription aims at reducing the morbidity related to patient sodium balance impairment. (C) 1999 by the National Kidney Foundation, Inc.
引用
收藏
页码:243 / 254
页数:12
相关论文
共 10 条
[1]  
Di Giulio S., 1994, Blood Purification, V12, P174
[2]   The theory of membrane equilibria [J].
Donnan, FG .
CHEMICAL REVIEWS, 1924, 1 (01) :73-90
[3]  
Gotch F A, 1980, Proc Clin Dial Transplant Forum, V10, P12
[4]   Monitoring sodium removal and delivered dialysis by conductivity [J].
Locatelli, F ;
DiFilippo, S ;
Manzoni, C ;
Corti, M ;
Andrulli, S ;
Pontoriero, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1995, 18 (11) :716-721
[5]   Ionic dialysance as a method for the on-line monitoring of delivered dialysis without blood sampling [J].
Manzoni, C ;
DiFilippo, S ;
Corti, M ;
Locatelli, F .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1996, 11 (10) :2023-2030
[6]   OPTIMIZATION OF SODIUM-BALANCE DURING HEMODIALYSIS BY ROUTINE IMPLEMENTATION OF KINETIC MODELING - TECHNICAL ASPECTS AND PRELIMINARY CLINICAL-STUDY [J].
PETITCLERC, T ;
HAMANI, A ;
JACOBS, C .
BLOOD PURIFICATION, 1992, 10 (5-6) :309-316
[7]   A MODEL FOR NONINVASIVE ESTIMATION OF IN-VIVO DIALYZER PERFORMANCES AND PATIENTS CONDUCTIVITY DURING HEMODIALYSIS [J].
PETITCLERC, T ;
GOUX, N ;
REYNIER, AL ;
BENE, B .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (08) :585-591
[8]  
PETITCLERC T, 1995, NEPHROL DIAL TRANSPL, V10, P212
[9]  
Petitclerc T, 1996, NEPHROL DIAL TRANSPL, V11, P35
[10]  
Sanz-Moreno C., 1995, Nephrology Dialysis Transplantation, V10, P1023