Is computerised 3D templating more accurate than 2D templating to predict size of components in primary total hip arthroplasty?

被引:40
作者
Schiffner, Erik [1 ]
Latz, David [1 ]
Jungbluth, Pascal [1 ]
Grassmann, Jan P. [1 ]
Tanner, Stephan [1 ]
Karbowski, Alfred [2 ]
Windolf, Joachim [1 ]
Schneppendahl, Johannes [1 ]
机构
[1] Heinrich Heine Univ Hosp, Dept Trauma & Hand Surg, Moorenstr 5, D-40225 Dusseldorf, Germany
[2] Hosp Augustinians, Dept Orthopaed Surg, Cologne, Germany
关键词
Cup; hip; stem; total hip arthroplasty; 3D templating; PRIMARY STABILITY; REPLACEMENT; KNEE; RECONSTRUCTION; TOMOGRAPHY; SOFTWARE;
D O I
10.1177/1120700018776311
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Introduction: The aim of this study was to compare the accuracy of preoperative templating in total hip arthroplasty (THA) using conventional 2-dimensional (2D) and computed tomography (CT)-based 3-dimensional (3D) measures. Methods: One hundred and sixteen consecutive primary THAs were analysed. The preoperative diagnosis was primary osteoarthritis in all cases. The 2D templating and the 3D templating were performed by two different residents. All templating results were available for the orthopaedic surgeon performing the procedure. Accuracies with regard to the predicted and actual implant sizes were determined for each procedure. Implantation of the size as planned was defined as "exact", whereas the use of components within one size larger or smaller (+/- 1) as planned were defined as "accurate." Results: The 3D templating was significantly more accurate in predicting implant sizing compared to 2D templating for primary total hip arthroplasty (THA). The difference was statistically significant for the cup templating (''exact'' p = 0.02; ''accurate'' p = 0.01) and for the stem templating (''exact'' p = 0.04; ''accurate'' p = 0.01). Conclusion: Our results support the superiority of 3D templating over 2D templating in predicting implant size.
引用
收藏
页码:270 / 275
页数:6
相关论文
共 32 条
[1]
Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system [J].
Bertz, Ari ;
Indrekvam, Kari ;
Ahmed, Mohamed ;
Englund, Erling ;
Sayed-Noor, Arkan S. .
SKELETAL RADIOLOGY, 2012, 41 (10) :1245-1249
[2]
Blackley H R, 2000, Instr Course Lect, V49, P3
[3]
DETERMINATION OF ACCURACY OF PREOPERATIVE TEMPLATING OF NONCEMENTED FEMORAL PROSTHESES [J].
CARTER, LW ;
STOVALL, DO ;
YOUNG, TR .
JOURNAL OF ARTHROPLASTY, 1995, 10 (04) :507-513
[4]
Primary Total Hip Arthroplasty With an Uncemented Femoral Component Five- to Nine-Year Results [J].
Casper, David S. ;
Kim, Gregory K. ;
Restrepo, Camilo ;
Parvizi, Javad ;
Rothman, Richard H. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (06) :838-841
[5]
Eckrich S G, 1994, J Arthroplasty, V9, P419, DOI 10.1016/0883-5403(94)90053-1
[6]
The value of preoperative planning for total hip arthroplasty [J].
Eggli, S ;
Pisan, M ;
Muller, ME .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (03) :382-390
[7]
The Accuracy of Digital Templating in Uncemented Total Hip Arthroplasty [J].
Gamble, Patrick ;
de Beer, Justin ;
Petruccelli, Danielle ;
Winemaker, Mitchell .
JOURNAL OF ARTHROPLASTY, 2010, 25 (04) :529-532
[8]
Goldstein WM, 2005, ORTHOPEDICS, V28, pS1037
[9]
Primary stability in cementless femoral stems:: custom-made versus conventional femoral prosthesis [J].
Götze, C ;
Steens, W ;
Vieth, V ;
Poremba, C ;
Claes, L ;
Steinbeck, J .
CLINICAL BIOMECHANICS, 2002, 17 (04) :267-273
[10]
Comparisons of Preoperative Three-Dimensional Planning and Surgical Reconstruction in Primary Cementless Total Hip Arthroplasty [J].
Hassani, Hassen ;
Cherix, Stephane ;
Ek, Eugene T. ;
Ruediger, Hannes A. .
JOURNAL OF ARTHROPLASTY, 2014, 29 (06) :1273-1277