The superiority of polymerase chain reaction over an amplified enzyme immunoassay for the detection of genital chlamydial infections

被引:24
作者
Jalal, H
Stephen, H
Al-Suwaine, A
Sonnex, C
Carne, C
机构
[1] Addenbrookes Hosp, Clin Microbiol & Publ Hlth Lab, Cambridge CB2 2QW, England
[2] King Faisal Specialist Hosp & Res Ctr, Riyadh 11211, Saudi Arabia
[3] Addenbrookes Hosp, Dept Genitourinary Med, Cambridge, England
关键词
D O I
10.1136/sti.2005.015362
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background/objectives: The polymer conjugate enhanced enzyme immunoassay (IDEIA) and Cobas Amplicor polymerase chain reaction Chlamydia trachomatis (CT) (Amplicor PCR) are two commonly used assays for the diagnosis of CT infection. The performance of these assays was compared for the diagnosis of genital CT infection among 1000 consecutive patients attending a genitourinary medicine (GUM) clinic. Confirmation of positive results and the clinical significance of the absence of cryptic plasmid in chlamydia on the diagnosis of infection by Amplicor PCR were also investigated. Methods: IDEIA, Amplicor PCR, and two nested in-house PCR assays targeting cryptic plasmid and omp1 gene were performed on all samples. DNA from Amplicor PCR negative samples was pooled for in-house PCR assays. Each pool contained DNA from seven Amplicor PCR negative samples. Results: Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and efficiency of IDEIA in the diagnosis of genital CT infection were 80%, 97%, 80%, 97%, and 95%, respectively. Sensitivity, specificity, PPV, NPV and efficiency of Amplicor PCR were 99%, 98%, 89%, 100%, and 98%, respectively. 16 (11%) of 144 Amplicor PCR positive results were identified as false positive by in-house PCR assays. No isolate of plasmid free CT was detected among the study population. Conclusions: IDEIA should not be used for the diagnosis of CT infection because of its poor sensitivity. Although the analytic specificity of Amplicor PCR was 98%, because of the adverse medical, social, and psychological impact of false positive results for patients, confirmation of Amplicor PCR positive results by a different assay with comparable sensitivity is essential. Amplification assays targeting cryptic plasmid are appropriate for the diagnosis of genital CT infections.
引用
收藏
页码:37 / 40
页数:4
相关论文
共 21 条
[11]   DEVELOPMENT AND CLINICAL-EVALUATION OF A POLYMERASE CHAIN-REACTION TEST FOR DETECTION OF CHLAMYDIA-TRACHOMATIS [J].
OSSEWAARDE, JM ;
RIEFFE, M ;
ROZENBERGARSKA, M ;
OSENKOPPELE, PM ;
NAWROCKI, RP ;
VANLOON, AM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (08) :2122-2128
[12]   THE 7.5-KB PLASMID PRESENT IN CHLAMYDIA-TRACHOMATIS IS NOT ESSENTIAL FOR THE GROWTH OF THIS MICROORGANISM [J].
PETERSON, EM ;
MARKOFF, BA ;
SCHACHTER, J ;
DELAMAZA, LM .
PLASMID, 1990, 23 (02) :144-148
[13]   Reproducibility problems with the AMPLICOR PCR Chlamydia trachomatis test [J].
Peterson, EM ;
Darrow, V ;
Blanding, J ;
Aarnaes, S ;
delaMaza, LM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (04) :957-959
[14]  
QI AN, 1990, J CLIN MICROBIOL, V30, P2814
[15]   Identification of a Chlamydia trachomatis serovar E urogenital isolate which lacks the cryptic plasmid [J].
Stothard, DR ;
Williams, JA ;
Van Der Pol, B ;
Jones, RB .
INFECTION AND IMMUNITY, 1998, 66 (12) :6010-6013
[16]   Detection of Chlamydia trachomatis in vaginal specimens from female commercial sex workers using a new improved enzyme immunoassay [J].
Tanaka, M ;
Nakayama, H ;
Yoshida, H ;
Takahashi, K ;
Nagafuji, T ;
Hagiwara, T ;
Kumazawa, J .
SEXUALLY TRANSMITTED INFECTIONS, 1998, 74 (06) :435-438
[17]   Evaluation of a new amplified enzyme immunoassay (EIA) for the detection of Chlamydia trachomatis in male urine, female endocervical swab, and patient obtained vaginal swab specimens [J].
Tanaka, M ;
Nakayama, H ;
Sagiyama, K ;
Haraoka, M ;
Yoshida, H ;
Hagiwara, T ;
Akazawa, K ;
Naito, S .
JOURNAL OF CLINICAL PATHOLOGY, 2000, 53 (05) :350-354
[18]   Plasmid diversity in Chlamydia [J].
Thomas, NS ;
Lusher, M ;
Storey, CC ;
Clarke, IN .
MICROBIOLOGY-SGM, 1997, 143 :1847-1854
[19]   Multicenter evaluation of the AMPLICOR and automated COBAS AMPLICOR CT/NG tests for detection of Chlamydia trachomatis [J].
Van der Pol, B ;
Quinn, TC ;
Gaydos, CA ;
Crotchfelt, K ;
Schachter, J ;
Moncada, J ;
Jungkind, D ;
Martin, DH ;
Turner, B ;
Peyton, C ;
Jones, RB .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (03) :1105-1112
[20]   Multicenter evaluation of the fully automated COBAS AMPLICOR PCR test for detection of Chlamydia trachomatis in urogenital specimens [J].
Vincelette, J ;
Schirm, J ;
Bogard, M ;
Bourgault, AM ;
Luijt, DS ;
Bianchi, A ;
Vader, PCV ;
Butcher, A ;
Rosenstraus, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (01) :74-80