The effect of the Oxford uncemented medial compartment arthroplasty on the bone mineral density and content of the proximal tibia

被引:16
作者
Hooper, G. J. [1 ]
Gilchrist, N. [1 ]
Maxwell, R. [1 ]
March, R. [1 ]
Heard, A. [1 ]
Frampton, C. [1 ]
机构
[1] Univ Otago Christchurch, Christchurch, New Zealand
关键词
TOTAL KNEE REPLACEMENT; NATIONAL JOINT REGISTRY; FOLLOW-UP; FIXED-BEARING; RADIOLUCENCY; SURVIVAL; REVISION;
D O I
10.1302/0301-620X.95B11.31509
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
We studied the bone mineral density (BMD) and the bone mineral content (BMC) of the proximal tibia in patients with a well-functioning uncemented Oxford medial compartment arthroplasty using the Lunar iDXA bone densitometer. Our hypothesis was that there would be decreased BMD and BMC adjacent to the tibial base plate and increased BMD and BMC at the tip of the keel. There were 79 consecutive patients (33 men, 46 women) with a mean age of 65 years (44 to 84) with a minimum two-year follow-up (mean 2.6 years (2.0 to 5.0)) after unilateral arthroplasty, who were scanned using a validated standard protocol where seven regions of interest (ROI) were examined and compared with the contralateral normal knee. All had well-functioning knees with a mean Oxford knee score of 43 (14 to 48) and mean Knee Society function score of 90 (20 to 100), showing a correlation with the increasing scores and higher BMC and BMD values in ROI 2 in the non-implanted knee relative to the implanted knee (p = 0.013 and p = 0.015, respectively). The absolute and percentage changes in BMD and BMC were decreased in all ROIs in the implanted knee compared with the non-implanted knee, but this did not reach statistical significance. Bone loss was markedly less than reported losses with total knee replacement. There was no significant association with side, although there was a tendency for the BMC to decrease with age in men. The BMC was less in the implanted side relative to the non-implanted side in men compared with women in ROI 2 (p = 0.027), ROI 3 (p = 0.049) and ROI 4 (p = 0.029). The uncemented Oxford medial compartment arthroplasty appears to allow relative preservation of the BMC and BMD of the proximal tibia, suggesting that the implant acts more physiologically than total knee replacement. Peri-prosthetic bone loss is an important factor in assessing long-term implant stability and survival, and the results of this study are encouraging for the long-term outcome of this arthroplasty.
引用
收藏
页码:1480 / 1483
页数:4
相关论文
共 22 条
[1]
Peri-prosthetic bone mineral density after total knee arthroplasty -: Cemented versus cementless fixation [J].
Abu-Rajab, R. B. ;
Watson, W. S. ;
Walker, B. ;
Roberts, J. ;
Gallacher, S. J. ;
Meek, R. M. D. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (05) :606-613
[2]
[Anonymous], 2009, NZ ORTHOPAEDIC ASS N
[3]
Mid-term equivalent survival of medial and lateral unicondylar knee replacement AN ANALYSIS OF DATA FROM A NATIONAL JOINT REGISTRY [J].
Baker, P. N. ;
Jameson, S. S. ;
Deehan, D. J. ;
Gregg, P. J. ;
Porter, M. ;
Tucker, K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (12) :1641-1648
[4]
Comparison of patient-reported outcome measures following total and unicondylar knee replacement [J].
Baker, P. N. ;
Petheram, T. ;
Jameson, S. S. ;
Avery, P. J. ;
Reed, M. R. ;
Gregg, P. J. ;
Deehan, D. J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (07) :919-927
[5]
Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study [J].
Callaghan, JJ ;
Squire, MW ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :705-711
[6]
Davidson D, 2009, AUSTR ORTHOPAEDIC AS
[7]
Questionnaire on the perceptions of patients about total knee replacement [J].
Dawson, J ;
Fitzpatrick, R ;
Murray, D ;
Carr, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01) :63-69
[8]
Measurement of Bone Density Around the Oxford Medial Compartment Knee Replacement Using iDXA. A Precision Study [J].
Gilchrist, Nigel ;
Hooper, Gary ;
Frampton, Christopher ;
Maguire, Patricia ;
Heard, Allison ;
March, Rachel L. ;
Maxwell, Rod ;
Penny, Ian .
JOURNAL OF CLINICAL DENSITOMETRY, 2013, 16 (02) :178-182
[9]
The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome [J].
Gulati, A. ;
Chau, R. ;
Pandit, H. G. ;
Gray, H. ;
Price, A. J. ;
Dodd, C. A. F. ;
Murray, D. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (07) :896-902
[10]
Outcome of revision of unicompartmental knee replacement 1,948 cases from the Australian Orthopaedic Association National Joint Replacement Registry, 1999-2008 [J].
Hang, Jacqueline R. ;
Stanford, Tyman E. ;
Graves, Stephen E. ;
Davidson, David C. ;
de Steiger, Richard N. ;
Miller, Lisa N. .
ACTA ORTHOPAEDICA, 2010, 81 (01) :95-98