Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study

被引:146
作者
Callaghan, JJ
Squire, MW
Goetz, DD
Sullivan, PM
Johnston, RC
机构
[1] Iowa Methodist Hosp, Des Moines, IA USA
[2] Univ Iowa, Coll Med, Iowa City, IA USA
关键词
D O I
10.2106/00004623-200005000-00011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although the LCS (low contact stress) rotating-platform mobile-bearing knee replacement has been used extensively, there have been few intermediate or long-term clinical and radiographic follow-up studies evaluating the device. The purpose of this study was to report the nine to twelve-year results of a consecutive series of patients who had a primary total knee replacement performed with this device. Methods: Between November 1985 and November 1988, the senior author (R. C. J.) performed 119 consecutive total knee arthroplasties in eighty-six patients with LCS rotating-platform femoral and tibial components and a Townley all-polyethylene dome patellar component. All components were fixed with cement. The average age of the patients at the time of the operation was seventy years (range, thirty-seven to eighty-eight years). Fifty-two patients (seventy-six knees) were female, and thirty-four patients (forty-three knees) were male. The patients were evaluated with clinical knee ratings and radiographic analysis nine to twelve years following the knee replacement. Results: At the time of the nine to twelve-year follow-up, sixty-four patients (eighty-six knees) were alive, eighteen patients (twenty-eight knees) had died, and four patients (five knees) had been lost to follow-up, Of the 114 knees in the eighty-two patients for whom the final outcome was known, none required a reoperation and none had a dislocation of the mobile-bearing prosthesis. For the forty-five patients (sixty-six knees) who returned for final clinical and radiographic follow-up examinations at nine to twelve years, the average clinical and functional Knee Society ratings were 30 points (range, 2 to 70 points) and 44 points (range, 0 to 80 points) preoperatively and 90 points (range, 63 to 102 points) and 75 points (range, 30 to 100 points) at the final follow-up evaluation, The average Hospital for Special Surgery knee rating was 57 points (range, 28 to 80 points) preoperatively and 84 points (range, 59 to 97 points) at the final follow-up evaluation. The average active range of knee flexion was from 0 degrees (range, 0 to 10 degrees) to 102 degrees (range, 15 to 120 degrees) at the final follow-up evaluation, Seven of the sixty-six knees were painful anteriorly. There was no periprosthetic osteolysis and no evidence of loosening on follow-up radiographs, Conclusions After nine to twelve years of followup, the cemented LCS rotating-platform knee replacement was found to be performing well, with durable clinical and radiographic results.
引用
收藏
页码:705 / 711
页数:7
相关论文
共 45 条
[1]   POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE [J].
ARGENSON, JN ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02) :228-232
[2]   Resurfacing of the patella in total knee arthroplasty - A prospective, randomized, double-blind study [J].
Barrack, RL ;
Wolfe, MW ;
Waldman, DA ;
Milicic, M ;
Bertot, AJ ;
Myers, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (08) :1121-1131
[3]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[4]  
BERT JM, 1990, CLIN ORTHOP RELAT R, V254, P211
[5]   THE NEW-JERSEY LOW-CONTACT-STRESS KNEE REPLACEMENT SYSTEM - BIOMECHANICAL RATIONALE AND REVIEW OF THE 1ST 123 CEMENTED CASES [J].
BUECHEL, FF ;
PAPPAS, MJ .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1986, 105 (04) :197-204
[6]  
BUECHEL FF, 1991, CLIN ORTHOP RELAT R, P190
[7]  
BUECHEL FF, 1989, ORTHOP CLIN N AM, V20, P147
[8]  
BUECHEL FF, 1990, CLIN ORTHOP RELAT R, V260, P162
[9]  
BUECHEL FF, 1989, CLIN ORTHOP RELAT R, V248, P34
[10]   PATIENT OUTCOMES FOLLOWING TRICOMPARTMENTAL TOTAL KNEE REPLACEMENT - A METAANALYSIS [J].
CALLAHAN, CM ;
DRAKE, BG ;
HECK, DA ;
DITTUS, RS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (17) :1349-1357