Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study

被引:146
作者
Callaghan, JJ
Squire, MW
Goetz, DD
Sullivan, PM
Johnston, RC
机构
[1] Iowa Methodist Hosp, Des Moines, IA USA
[2] Univ Iowa, Coll Med, Iowa City, IA USA
关键词
D O I
10.2106/00004623-200005000-00011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although the LCS (low contact stress) rotating-platform mobile-bearing knee replacement has been used extensively, there have been few intermediate or long-term clinical and radiographic follow-up studies evaluating the device. The purpose of this study was to report the nine to twelve-year results of a consecutive series of patients who had a primary total knee replacement performed with this device. Methods: Between November 1985 and November 1988, the senior author (R. C. J.) performed 119 consecutive total knee arthroplasties in eighty-six patients with LCS rotating-platform femoral and tibial components and a Townley all-polyethylene dome patellar component. All components were fixed with cement. The average age of the patients at the time of the operation was seventy years (range, thirty-seven to eighty-eight years). Fifty-two patients (seventy-six knees) were female, and thirty-four patients (forty-three knees) were male. The patients were evaluated with clinical knee ratings and radiographic analysis nine to twelve years following the knee replacement. Results: At the time of the nine to twelve-year follow-up, sixty-four patients (eighty-six knees) were alive, eighteen patients (twenty-eight knees) had died, and four patients (five knees) had been lost to follow-up, Of the 114 knees in the eighty-two patients for whom the final outcome was known, none required a reoperation and none had a dislocation of the mobile-bearing prosthesis. For the forty-five patients (sixty-six knees) who returned for final clinical and radiographic follow-up examinations at nine to twelve years, the average clinical and functional Knee Society ratings were 30 points (range, 2 to 70 points) and 44 points (range, 0 to 80 points) preoperatively and 90 points (range, 63 to 102 points) and 75 points (range, 30 to 100 points) at the final follow-up evaluation, The average Hospital for Special Surgery knee rating was 57 points (range, 28 to 80 points) preoperatively and 84 points (range, 59 to 97 points) at the final follow-up evaluation. The average active range of knee flexion was from 0 degrees (range, 0 to 10 degrees) to 102 degrees (range, 15 to 120 degrees) at the final follow-up evaluation, Seven of the sixty-six knees were painful anteriorly. There was no periprosthetic osteolysis and no evidence of loosening on follow-up radiographs, Conclusions After nine to twelve years of followup, the cemented LCS rotating-platform knee replacement was found to be performing well, with durable clinical and radiographic results.
引用
收藏
页码:705 / 711
页数:7
相关论文
共 45 条
[31]   SURVIVORSHIP ANALYSIS OF TOTAL KNEE ARTHROPLASTY - CUMULATIVE RATES OF SURVIVAL OF 9200 TOTAL KNEE ARTHROPLASTIES [J].
RAND, JA ;
ILSTRUP, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (03) :397-409
[32]  
Ritter M A, 1989, J Arthroplasty, V4, P293, DOI 10.1016/S0883-5403(89)80029-4
[33]   Results and complications of the low contact stress knee prosthesis [J].
Sánchez-Sotelo, O ;
Ordoñez, JM ;
Prats, SB .
JOURNAL OF ARTHROPLASTY, 1999, 14 (07) :815-821
[34]   Total knee arthroplasty with the PFC system - Results at a minimum of ten years and survivorship analysis [J].
Schai, PA ;
Thornhill, TS ;
Scott, RD .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (05) :850-858
[35]  
SCOTT RD, 1986, CLIN ORTHOP RELAT R, P100
[36]   RESULTS AFTER KNEE REPLACEMENT WITH A POSTERIOR CRUCIATE-SUBSTITUTING PROSTHESIS [J].
SCOTT, WN ;
RUBINSTEIN, M ;
SCUDERI, G .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (08) :1163-1174
[37]   SURVIVORSHIP OF CEMENTED KNEE REPLACEMENTS [J].
SCUDERI, GR ;
INSALL, JN ;
WINDSOR, RE ;
MORAN, MC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (05) :798-803
[38]  
Sorrells RB, 1996, ORTHOPEDICS, V19, P793
[39]   POSTERIOR STABILIZED PROSTHESIS - RESULTS AFTER FOLLOW-UP OF 9 TO 12 YEARS [J].
STERN, SH ;
INSALL, JN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :980-989
[40]   Morphology of the transepicondylar axis and its application in primary and revision total knee arthroplasty [J].
Stiehl, JB ;
Abbott, BD .
JOURNAL OF ARTHROPLASTY, 1995, 10 (06) :785-789