Microwave ablation for atrial fibrillation: Dose-response curves in the cardioplegia-arrested and beating heart

被引:38
作者
Gaynor, SL [1 ]
Byrd, GD [1 ]
Diodato, MD [1 ]
Ishii, Y [1 ]
Lee, AM [1 ]
Prasad, SM [1 ]
Gopal, J [1 ]
Schuessler, RB [1 ]
Damiano, RJ [1 ]
机构
[1] Washington Univ, Sch Med, Div Cardiothorac Surg, Dept Surg, St Louis, MO 63110 USA
关键词
D O I
10.1016/j.athoracsur.2005.06.062
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Microwave ablation has been used to replace the traditional incisions used in the surgical treatment of atrial fibrillation. However, dose-response curves have not been established in surgically relevant models. The purpose of this study was to develop dose-response curves for the Flex 10 (Guidant, Inc) microwave device in both the acute cardioplegia-arrested heart and on the beating heart. Methods. Twelve domestic pigs (40 to 45 kg) were subjected to microwave ablation in either the arrested (n = 6) or beating heart (n = 6). The cardioplegia-arrested heart was maintained at 10 degrees to 15 degrees C while six atrial endocardial and seven right ventricular epicardial lesions were created in each animal. On the beating heart, six right atrial and seven ventricular epicardial lesions were created. Ablations were performed for 15, 30, 45, 60, 90,120, and 150 seconds (65 W, 2.45 GHz). The tissue was stained with 2,3,5-triphenyl-tetrazolium chloride, and sectioned at 5-mm intervals. Lesion depth and width were determined from digital micrographs. Results. Mean atrial wall thickness was 2.8 mm (range, 1 to 8 mm). In the arrested heart, 94% of atrial lesions were transmural at 45 seconds and 100% were transmural at 90 seconds. In the beating heart, only 20% of atrial lesions were transmural despite prolonged ablation times (90 seconds). Ventricular lesion width and depth increased with duration of application, and were similar on the arrested and beating hearts. Conclusions. Microwave ablation produces linear dose-response curves. Transmural lesions can be reliably produced on the arrested heart, but not consistently on the beating heart.
引用
收藏
页码:72 / 77
页数:6
相关论文
共 28 条
[1]  
Adegboyega PA, 1997, ARCH PATHOL LAB MED, V121, P1063
[2]  
Cox J L, 2000, Semin Thorac Cardiovasc Surg, V12, P15
[3]  
Cox JL, 1997, ANNU REV MED, V48, P511
[4]   THE SURGICAL-TREATMENT OF ATRIAL-FIBRILLATION .2. INTRAOPERATIVE ELECTROPHYSIOLOGIC MAPPING AND DESCRIPTION OF THE ELECTROPHYSIOLOGIC BASIS OF ATRIAL-FLUTTER AND ATRIAL-FIBRILLATION [J].
COX, JL ;
CANAVAN, TE ;
SCHUESSLER, RB ;
CAIN, ME ;
LINDSAY, BD ;
STONE, C ;
SMITH, PK ;
CORR, PB ;
BOINEAU, JP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 101 (03) :406-426
[5]   The long-term outcome of patients with coronary disease and atrial fibrillation undergoing the Cox maze procedure [J].
Damiano, RJ ;
Gaynor, SL ;
Bailey, M ;
Prasad, S ;
Cox, JL ;
Boineau, JP ;
Schuessler, RP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (06) :2016-2021
[6]   Alternative energy sources for atrial ablation: Judging the new technology [J].
Damiano, RJ .
ANNALS OF THORACIC SURGERY, 2003, 75 (02) :329-330
[7]   Microwave ablation for atrial fibrillation: Dose-response curves in the cardioplegia-arrested and beating heart [J].
Gaynor, SL ;
Byrd, GD ;
Diodato, MD ;
Ishii, Y ;
Lee, AM ;
Prasad, SM ;
Gopal, J ;
Schuessler, RB ;
Damiano, RJ .
ANNALS OF THORACIC SURGERY, 2006, 81 (01) :72-77
[8]   Contemporary surgical treatment for atrial fibrillation [J].
Gillinov, AM ;
McCarthy, PM ;
Marrouche, N ;
Natale, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (07) :1641-1644
[9]   Microwave ablation of atrial fibrillation during mitral valve operations [J].
Gillinov, AM ;
Smedira, NG ;
Cosgrove, DM .
ANNALS OF THORACIC SURGERY, 2002, 74 (04) :1259-1261
[10]  
HOENICKE EM, 2000, SURG FORUM, V51, P79