Prediction of labor and delivery by transperineal ultrasound in pregnancies with prelabor rupture of membranes at term

被引:148
作者
Eggebo, TM [1 ]
Gjessing, LK
Heien, C
Smedvig, E
Okland, I
Romundstad, P
Salvesen, KA
机构
[1] Stavanger Univ Hosp, Dept Obstet & Gynaecol, N-4068 Stavanger, Norway
[2] Univ Trondheim Hosp, St Olavs Hosp, Dept Publ Hlth, NTNU, Trondheim, Norway
[3] Univ Trondheim Hosp, St Olavs Hosp, Natl Ctr Fetal Med, Dept Obstet & Gynaecol, Trondheim, Norway
关键词
cervical length; engagement of fetal head; outcome of labor; PROM; ultrasound;
D O I
10.1002/uog.2744
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To evaluate whether engagement of the fetal bead or cervical length in women with premature rupture of membranes (PROM) at term, are associated with time from PROM to delivery or need for operative delivery. Methods A transperineal ultrasound examination was performed in 152 women with a single live fetus in cephalic presentation after PROM (at > 37 gestational weeks). The shortest distance from the outer bony limit of the fetal skull to the skin surface of the perineum was measured in a transverse view, and the cervical length was measured in a sagittal view. The time front PROM to delivery was tested in a Cox regression analysis with ultrasound measurements, parity, maternal age, body mass index and birth weight as possible predictive factors. Results The bead-perineal distance was associated with the time from PROM to delivery (log rank test, P < 0.001). Thirty-six hours after PROM, 32% (95% CI, 15-49) of women with a short bead-perineal distance (< 45 mm) and 43% (95% CI, 24-62) of women with a long distance (>= 45 mm) were still in labor. Women with a short bead-perineal distance bad fewer Cesarean sections, less use of epidural analgesia and a shorter time in active labor, and their babies bad a higher pH in the umbilical artery. The measured cervical length was not associated independently with time to delivery. Conclusion Transperineal ultrasound measurements of fetal bead engagement may help clinicians to predict the course of labor in women with PROM. Copyright (c) 2006 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:387 / 391
页数:5
相关论文
共 17 条
[1]   Comparison of transvaginal digital examination with intrapartum sonography to determine fetal head position before instrumental delivery [J].
Akmal, S ;
Kametas, N ;
Tsoi, E ;
Hargreaves, C ;
Nicolaides, KH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 21 (05) :437-440
[2]  
Akmal S, 2002, J Matern Fetal Neonatal Med, V12, P172, DOI 10.1080/713605646
[3]   Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[4]   Measuring engagement of the fetal head: validity and reproducibility of a new ultrasound technique [J].
Dietz, HP ;
Lanzarone, V .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 25 (02) :165-168
[5]  
GRANT JMK, 1989, EFFECTIVE CARE PREGN
[6]  
HERTZBERG BS, 1994, J ULTRAS MED, V13, P933
[7]  
Hertzberg BS, 2001, J ULTRAS MED, V20, P1071
[8]   The vague of ultrasound in the prediction of successful induction of labor [J].
Rane, SM ;
Guirgis, RR ;
Higgins, B ;
Nicolaides, KH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 24 (05) :538-549
[9]   Pre-induction sonographic measurement of cervical length in prolonged pregnancy: the effect of parity in the prediction of induction-to-delivery interval [J].
Rane, SM ;
Pandis, GK ;
Guirgis, RR ;
Higgins, B ;
Nicolaides, KH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :40-44
[10]   Pre-induction sonographic measurement of cervical length in prolonged pregnancy: the effect of parity in the prediction of the need for Cesarean section [J].
Rane, SM ;
Guirgis, RR ;
Higgins, B ;
Nicolaides, KH .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :45-48