Deep learning-guided attenuation and scatter correction without using anatomical images in brain PET/MRI

被引:6
作者
Bortolin, Karin [1 ]
Arabi, Hossein [1 ]
Zaidi, Habib [1 ]
机构
[1] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
来源
2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2019年
基金
瑞士国家科学基金会;
关键词
D O I
10.1109/nss/mic42101.2019.9059943
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Attenuation correction (AC) is essential component for quantitative PET imaging. However, in PET/MR imaging and dedicated brain PET devices, the attenuation map either suffers from a number of limitations or is not readily available in the absence of CT or transmission scan. To tackle this issue, a deep convolutional neural networks is proposed to perform joint attenuation and scatter correction in the image domain on the non-attenuation corrected PET images (PET-nonAC). The deep convolutional neural network used in this work benefits from dilated convolutions and residual connections to establish an end-to-end PET attenuation correction (PET-DirAC). For the training phase, data of 30 patients who underwent brain F-18-FDG PET/CT scans were used to generate reference PET-CTAC and PET-nonAC images. A five-fold cross- validation scheme was used for training/evaluation of the proposed algorithm. The quantitative accuracy of the proposed method was evaluated against the commercial segmentation-based method (2-class AC map referred to as MRAC). For quantitative analysis, tracer uptake estimated from PET-DirAC and PET-MRAC was compared to PET-CTAC. The relative SUV bias was calculated for bone, soft-tissue, air cavities and the entire head, separately. The proposed approach resulted in a mean relative absolute error (MRAE) of 4.1 +/- 7.5% and 5.8 +/- 10.4% for the entire head and bone regions, respectively. Conversely, MRAC led to a MRAE of 8.1 +/- 10.2% and 17.2 +/- 6.1% for these two regions, respectively. A mean SUV difference of 0.3 +/- 0.6 was achieved when using the direct method (DirAC) while the MRAC approach led to a mean SUV difference of -0.5 +/- 0.7. The quantitative analysis demonstrated the superior performance of the proposed deep learning-based AC approach over MRI segmentation-based method. The proposed approach seems promising to improve the quantitative accuracy of PET/MRI without the need for concurrent anatomical imaging.
引用
收藏
页数:3
相关论文
共 11 条
[1]  
Arabi H., 2019, EUR J NUCL MED MOL I
[2]   Comparative study of algorithms for synthetic CT generation from MRI: Consequences for MRI-guided radiation planning in the pelvic region [J].
Arabi, Hossein ;
Dowling, Jason A. ;
Burgos, Ninon ;
Han, Xiao ;
Greer, Peter B. ;
Koutsouvelis, Nikolaos ;
Zaidi, Habib .
MEDICAL PHYSICS, 2018, 45 (11) :5218-5233
[3]   Comparison of atlas-based techniques for whole-body bone segmentation [J].
Arabi, Hossein ;
Zaidi, Habib .
MEDICAL IMAGE ANALYSIS, 2017, 36 :98-112
[4]   Atlas-guided generation of pseudo-CT images for MRI-only and hybrid PET-MRI-guided radiotherapy treatment planning [J].
Arabi, Hossein ;
Koutsouvelis, Nikolaos ;
Rouzaud, Michel ;
Miralbell, Raymond ;
Zaidi, Habib .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (17) :6531-6552
[5]   Clinical Assessment of MR-Guided 3-Class and 4-Class Attenuation Correction in PET/MR [J].
Arabi, Hossein ;
Rager, Olivier ;
Alem, Asma ;
Varoquaux, Arthur ;
Becker, Minerva ;
Zaidi, Habib .
MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (02) :264-276
[6]   NiftyNet: a deep-learning platform for medical imaging [J].
Gibson, Eli ;
Li, Wenqi ;
Sudre, Carole ;
Fidon, Lucas ;
Shakir, Dzhoshkun I. ;
Wang, Guotai ;
Eaton-Rosen, Zach ;
Gray, Robert ;
Doel, Tom ;
Hu, Yipeng ;
Whyntie, Tom ;
Nachev, Parashkev ;
Modat, Marc ;
Barratt, Dean C. ;
Ourselin, Sebastien ;
Cardoso, M. Jorge ;
Vercauteren, Tom .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2018, 158 :113-122
[7]   On the Compactness, Efficiency, and Representation of 3D Convolutional Networks: Brain Parcellation as a Pretext Task [J].
Li, Wenqi ;
Wang, Guotai ;
Fidon, Lucas ;
Ourselin, Sebastien ;
Cardoso, M. Jorge ;
Vercauteren, Tom .
INFORMATION PROCESSING IN MEDICAL IMAGING (IPMI 2017), 2017, 10265 :348-360
[8]   Quantitative analysis of MRI-guided attenuation correction techniques in time-of-flight brain PET/MRI [J].
Mehranian, Abolfazl ;
Arabi, Hossein ;
Zaidi, Habib .
NEUROIMAGE, 2016, 130 :123-133
[9]   Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities [J].
Mehranian, Abolfazl ;
Arabi, Hossein ;
Zaidi, Habib .
MEDICAL PHYSICS, 2016, 43 (03) :1130-1155
[10]   Joint correction of attenuation and scatter in image space using deep convolutional neural networks for dedicated brain 18F-FDG PET [J].
Yang, Jaewon ;
Park, Dookun ;
Gullberg, Grant T. ;
Seo, Youngho .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (07)