Atlas-guided generation of pseudo-CT images for MRI-only and hybrid PET-MRI-guided radiotherapy treatment planning

被引:75
作者
Arabi, Hossein [1 ]
Koutsouvelis, Nikolaos [2 ]
Rouzaud, Michel [2 ]
Miralbell, Raymond [2 ]
Zaidi, Habib [1 ,3 ,4 ,5 ]
机构
[1] Univ Hosp Geneva, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[2] Univ Hosp Geneva, Div Radiat Oncol, Geneva, Switzerland
[3] Univ Geneva, Geneva Neurosci Ctr, Geneva, Switzerland
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[5] Univ Southern Denmark, Dept Nucl Med, DK-500 Odense, Denmark
基金
瑞士国家科学基金会;
关键词
PET/MRI; attenuation correction; atlas-based segmentation; pseudo-CT; radiation therapy; treatment planning; ULTRASHORT ECHO TIME; ATTENUATION CORRECTION; RADIATION-THERAPY; QUANTITATIVE-EVALUATION; SEGMENTATION; PET/MRI; BRAIN; REGISTRATION; PROSTATE; CLASSIFICATION;
D O I
10.1088/0031-9155/61/17/6531
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic resonance imaging (MRI)-guided attenuation correction (AC) of positron emission tomography (PET) data and/or radiation therapy (RT) treatment planning is challenged by the lack of a direct link between MRI voxel intensities and electron density. Therefore, even if this is not a trivial task, a pseudo-computed tomography (CT) image must be predicted from MRI alone. In this work, we propose a two-step (segmentation and fusion) atlas-based algorithm focusing on bone tissue identification to create a pseudo-CT image from conventional MRI sequences and evaluate its performance against the conventional MRI segmentation technique and a recently proposed multi-atlas approach. The clinical studies consisted of pelvic CT, PET and MRI scans of 12 patients with loco-regionally advanced rectal disease. In the first step, bone segmentation of the target image is optimized through local weighted atlas voting. The obtained bone map is then used to assess the quality of deformed atlases to perform voxel-wise weighted atlas fusion. To evaluate the performance of the method, a leave-one-out cross-validation (LOOCV) scheme was devised to find optimal parameters for the model. Geometric evaluation of the produced pseudo-CT images and quantitative analysis of the accuracy of PET AC were performed. Moreover, a dosimetric evaluation of volumetric modulated arc therapy photon treatment plans calculated using the different pseudo-CT images was carried out and compared to those produced using CT images serving as references. The pseudo-CT images produced using the proposed method exhibit bone identification accuracy of 0.89 based on the Dice similarity metric compared to 0.75 achieved by the other atlas-based method. The superior bone extraction resulted in a mean standard uptake value bias of -1.5 +/- 5.0% (mean +/- SD) in bony structures compared to -19.9 +/- 11.8% and -8.1 +/- 8.2% achieved by MRI segmentation-based (water-only) and atlas-guided AC. Dosimetric evaluation using dose volume histograms and the average difference between minimum/maximum absorbed doses revealed a mean error of less than 1% for the both target volumes and organs at risk. Two-dimensional (2D) gamma analysis of the isocenter dose distributions at 1%/1 mm criterion revealed pass rates of 91.40 +/- 7.56%, 96.00 +/- 4.11% and 97.67 +/- 3.6% for MRI segmentation, atlas-guided and the proposed methods, respectively. The proposed method generates accurate pseudo-CT images from conventional Dixon MRI sequences with improved bone extraction accuracy. The approach is promising for potential use in PET AC and MRI-only or hybrid PET/MRI-guided RT treatment planning.
引用
收藏
页码:6531 / 6552
页数:22
相关论文
共 53 条
[1]   The value of magnetic resonance imaging in target volume delineation of base of tongue tumours - A study using flexible surface coils [J].
Ahmed, Merina ;
Schmidt, Maria ;
Sohaib, Aslam ;
Kong, Christine ;
Burke, Kevin ;
Richardson, Cheryl ;
Usher, Marianne ;
Brennan, Sinead ;
Riddell, Angela ;
Davies, Mark ;
Newbold, Kate ;
Harrington, Kevin J. ;
Nutting, Christopher M. .
RADIOTHERAPY AND ONCOLOGY, 2010, 94 (02) :161-167
[2]   Evaluation of whole-body MR to CT deformable image registration [J].
Akbarzadeh, A. ;
Gutierrez, D. ;
Baskin, A. ;
Ay, M. R. ;
Ahmadian, A. ;
Alam, N. Riahi ;
Loevblad, K. O. ;
Zaidi, H. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04) :238-253
[3]   Combined PET/MR imaging in neurology: MR-based attenuation correction implies a strong spatial bias when ignoring bone [J].
Andersen, Flemming Littrup ;
Ladefoged, Claes Nohr ;
Beyer, Thomas ;
Keller, Sune Hogild ;
Hansen, Adam Espe ;
Hojgaard, Liselotte ;
Kjaer, Andreas ;
Law, Ian ;
Holm, Soren .
NEUROIMAGE, 2014, 84 :206-216
[4]   Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain [J].
Andreasen, Daniel ;
Van Leemput, Koen ;
Hansen, Rasmus H. ;
Andersen, Jon A. L. ;
Edmund, Jens M. .
MEDICAL PHYSICS, 2015, 42 (04) :1596-1605
[5]  
Arabi H, 2014, IEEE NUCL SCI S MED, P1
[6]   Magnetic resonance imaging-guided attenuation correction in whole-body PET/MRI using a sorted atlas approach [J].
Arabi, Hossein ;
Zaidi, Habib .
MEDICAL IMAGE ANALYSIS, 2016, 31 :1-15
[7]   MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence [J].
Berker, Yannick ;
Franke, Jochen ;
Salomon, Andre ;
Palmowski, Moritz ;
Donker, Henk C. W. ;
Temur, Yavuz ;
Mottaghy, Felix M. ;
Kuhl, Christiane ;
Izquierdo-Garcia, David ;
Fayad, Zahi A. ;
Kiessling, Fabian ;
Schulz, Volkmar .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (05) :796-804
[8]   MR-Based PET Attenuation Correction for PET/MR Imaging [J].
Bezrukov, Ilja ;
Mantlik, Frederic ;
Schmidt, Holger ;
Schoelkopf, Bernhard ;
Pichler, Bernd J. .
SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) :45-59
[9]   Computed Tomography-Magnetic Resonance Image Registration in Radiotherapy Treatment Planning [J].
Brunt, J. N. H. .
CLINICAL ONCOLOGY, 2010, 22 (08) :688-697
[10]   Attenuation Correction Synthesis for Hybrid PET-MR Scanners: Application to Brain Studies [J].
Burgos, Ninon ;
Cardoso, M. Jorge ;
Thielemans, Kris ;
Modat, Marc ;
Pedemonte, Stefano ;
Dickson, John ;
Barnes, Anna ;
Ahmed, Rebekah ;
Mahoney, Colin J. ;
Schott, Jonathan M. ;
Duncan, John S. ;
Atkinson, David ;
Arridge, Simon R. ;
Hutton, Brian F. ;
Ourselin, Sebastien .