Stereotactic core biopsy of breast microcalcifications: Comparison of film versus digital mammography, both using an add-on unit

被引:18
作者
Becker, L
Taves, D
McCurdy, L
Muscedere, G
Karlik, S
Ward, S
机构
[1] St Josephs Hlth Care, Dept Radiol, London, ON N6A 4V2, Canada
[2] London Hlth Sci Ctr, Dept Radiol, London, ON N6A 5A5, Canada
[3] St Michaels Hosp, Dept Radiol, Toronto, ON M5B 1W8, Canada
关键词
D O I
10.2214/ajr.177.6.1771451
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The goal of this study was to assess the accuracy of an add-on stereotactic unit for core biopsy of indeterminate breast microcalcifications and to compare digital with conventional stereotactic guidance. MATERIALS AND METHODS. We conducted a retrospective review of 232 lesions with indeterminate microcalcifications in 218 women who underwent stereotactically guided breast biopsies. All biopsies were performed using a standard mammography machine with an add-on unit, 121 with conventional and 111 with digital stereotactic guidance. Successful sampling of the lesion was determined by the detection of microcalcifications on specimen radiography or at pathology. RESULTS. Using the add-on unit, 219 (94.4%) of the 232 targeted lesions were successfully sampled. The size, location, number of cores per lesion, and histology of the lesions were not different between the conventional and digital stereotactic biopsy groups (p > 0.1). Indeterminate microcalcifications were missed on biopsy in nine (7.4%) of 121 cases using conventional radiography and in only four (3.6%) of 111 cases using digital imaging. Digital stereotactic guidance allowed sampling of lesions with fewer calcifications per square centimeter (p < 0.001). CONCLUSION. Sampling of indeterminate microcalcifications using a standard mammography machine and an add-on unit has a high accuracy, similar to rates reported for dedicated prone biopsy tables. An add-on unit offers the advantage of considerable cost and space savings. Relative to conventional radiography, digital stereotactic guidance allows lesions with fewer calcifications to be sampled and achieves a greater biopsy success rate. Immediate digital images in the biopsy room also permit rapid adjustment of alignment and minimize patient movement.
引用
收藏
页码:1451 / 1457
页数:7
相关论文
共 28 条
[1]   Comparison of histologic diagnosis between stereotactic core needle biopsy and open surgical biopsy [J].
Bauer, RL ;
Sung, J ;
Eckhert, KH ;
Koul, A ;
Castillo, NB ;
Nemoto, T .
ANNALS OF SURGICAL ONCOLOGY, 1997, 4 (04) :316-320
[2]   Atypical ductal hyperplasia: Histologic underestimation of carcinoma in tissue harvested from impalpable breast lesions using 11-gauge stereotactically guided directional vacuum-assisted biopsy [J].
Brem, RF ;
Behrndt, VS ;
Sanow, L ;
Gatewood, OMB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) :1405-1407
[3]   Percutaneous core biopsy of the breast: Effect of operator experience and number of samples on diagnostic accuracy [J].
Brenner, RJ ;
Fajardo, L ;
Fisher, PR ;
Dershaw, DD ;
Evans, WP ;
Bassett, L ;
Feig, S ;
Mendelson, E ;
Jackson, V ;
Margolin, FR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (02) :341-346
[4]   STEREOTAXIC NEEDLE CORE BIOPSY OF BREAST-LESIONS USING A REGULAR MAMMOGRAPHIC TABLE WITH AN ADAPTABLE STEREOTAXIC DEVICE [J].
CAINES, JS ;
MCPHEE, MD ;
KONOK, GP ;
WRIGHT, BA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :317-321
[5]   ISOLATED CLUSTERED MICROCALCIFICATIONS - DIAGNOSTIC-VALUE OF MAMMOGRAPHY - SERIES OF 400 CASES WITH SURGICAL VERIFICATION [J].
DELAFONTAN, B ;
DAURES, JP ;
SALICRU, B ;
EYNIUS, F ;
MIHURA, J ;
ROUANET, P ;
LAMARQUE, JL ;
NAJA, A ;
PUJOL, H .
RADIOLOGY, 1994, 190 (02) :479-483
[6]  
DONKERS DJ, 1992, RADIOLOGY, V183, P632
[7]   Decubitus stereotactic core biopsy of the breast: Technique and experience [J].
Doyle, AJ ;
Collins, JP ;
Forkert, CD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (03) :688-690
[8]   NONPALPABLE BREAST-LESIONS - RECOMMENDATIONS FOR BIOPSY BASED ON SUSPICION OF CARCINOMA AT MAMMOGRAPHY [J].
HALL, FM ;
STORELLA, JM ;
SILVERSTONE, DZ ;
WYSHAK, G .
RADIOLOGY, 1988, 167 (02) :353-358
[9]  
Lechner MC, 1999, RADIOLOGY, V213P, P106
[10]   Clinical management issues percutaneous core breast biopsy [J].
Liberman, L .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2000, 38 (04) :791-+