Cyclic Load and Failure Behavior of Arthroscopic Knots and High Strength Sutures

被引:88
作者
Barber, F. Alan [1 ]
Herbert, Morley A. [2 ]
Beavis, R. Cole [3 ]
机构
[1] Plano Orthoped & Sports Med Ctr, Plano, TX 75093 USA
[2] Med City Dallas Hosp, Adv Surg Inst, Dallas, TX USA
[3] Univ Saskatchewan, Div Orthopaed Surg, Saskatoon, SK, Canada
关键词
Arthroscopy; Biomechanics; Braided sutures; Knot tying; Rotator cuff; Ultra-high molecular weight polyethylene; ROTATOR CUFF REPAIR; LOCKING MECHANISM; TENSION OVERLOAD; LOOP SECURITY; ANCHORS; FIXATION; TEARS; SLIP;
D O I
10.1016/j.arthro.2008.09.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Purpose: To compare the biomechanical performance of several different sutures by evaluating knot security and load to failure strength using different arthroscopic knots. Methods: Eight different No. 2 sutures (Ethibond [Ethicon, Somerville. NJ], FiberWire [Arthrex, Naples, FL], Orthocord [DePuy-Mitek, Norwood, MA], Hi-Fi [ConMed Linvatec, Largo, FL], Ultrabraid [Smith & Nephew, Andover, MA], ForceFiber [Stryker Endoscopy, San Jose, CA], MagnumWire [ArthroCare, Sunnyvale, CA], and MaxBraid PE [Arthrotek, Warsaw, IN]) were tied arthroscopically into standardized loops using 6 different knots (Weston, Tennessee slider, Duncan, SMC, Revo, and San Diego knot) 10 times each. The suture loops were pretensioned to 10N, cycled between 10N and 45N for 1,000 cycles, and loaded to failure. The failure load for each suture. each knot, and slippage trend during cyclic loading was recorded. Results: The Revo and SMC knots (group A) were stronger than the Tennessee and San Diego knots (group 13), which were stronger than the Weston knot, which was stronger than the Duncan loop (P < .05). This pattern also coincided with the loads at which these knots slipped. Evaluating the sutures showed that Ethibond had lower failure loads than all other sutures and FiberWire showed statistically higher loads (P < .05). Duncan loops (97.5%) and Weston knots (86.3%) slipped more than other knots (P < .001), while the SMC and Revo knots slipped least. Ethibond sutures were least likely to slip. Conclusions: The Duncan loop and Weston knot were more likely to slip than all other knots. and caution should be exercised when tying them with high-strength sutures. The Revo, Tennessee slider, San Diego, and SMC knots were least likely to slip (P < .001). Clinical Relevance: While stronger than braided polyester sutures, newer sutures containing ultra-high molecular weight polyethylene have a greater tendency to slip. Backing up knots with 4 reversed half hitches with switched posts does not guarantee knot security.
引用
收藏
页码:192 / 199
页数:8
相关论文
共 27 条
[1]
Evaluation of 5 knots and 2 suture materials for arthroscopic rotator cuff repair: Very strong sutures can still slip [J].
Abbi, G ;
Espinoza, L ;
Odell, T ;
Mahar, A ;
Pedowitz, R .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (01) :38-43
[2]
Cyclic load testing and ultimate failure strength of biodegradable glenoid anchors [J].
Barber, F. Alan ;
Coons, David A. ;
Ruiz-Suarez, Michell .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (02) :224-228
[3]
Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures [J].
Barber, F. Alan ;
Coons, David A. ;
Ruiz-Suarez, Michell .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (04) :355-360
[4]
Sutures and suture anchors - Update 2006 [J].
Barber, F. Alan ;
Herbert, Morley A. ;
Coons, David A. ;
Boothby, Michael H. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (10) :1063-1069
[5]
Cyclic loading of anchor-based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation [J].
Burkhart, SS ;
Pagan, JLD ;
Wirth, MA ;
Athanasiou, KA .
ARTHROSCOPY, 1997, 13 (06) :720-724
[6]
Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure [J].
Burkhart, SS ;
Johnson, TC ;
Wirth, MA ;
Athanasiou, KA .
ARTHROSCOPY, 1997, 13 (02) :172-176
[7]
Biomechanical comparison of 3 suture anchor configurations for repair of type II SLAP lesions [J].
Domb, Benjamin G. ;
Ehteshami, John R. ;
Shindle, Michael K. ;
Gulotta, Lawrence ;
Zoghi-Moghadam, Mohamad ;
MacGillivray, John D. ;
Altchek, David W. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (02) :135-140
[8]
A biomechanical comparison of arthroscopic sliding and sliding-locking knots [J].
Elkousy, HA ;
Sekiya, LCDRJK ;
Stabile, KJ ;
McMahon, PJ .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (02) :204-210
[9]
The arthroscopic square knot: A biomechanical comparison with open and arthroscopic knots [J].
Elkousy, Hussein ;
Hammerman, Steven M. ;
Edwards, T. Bradley ;
Warnock, K. Mathew ;
O'Connor, Daniel P. ;
Ambrose, Catherine ;
Meyers, Deidre ;
Gartsman, Gary M. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (07) :736-741
[10]
The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears [J].
Galatz, LM ;
Ball, CM ;
Teefey, SA ;
Middleton, WD ;
Yamaguchi, K .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (02) :219-224