The effect of pre-soaking and time in the ultrasonic cleaner on the cleanliness of sterilized endodontic files

被引:33
作者
Aasim, SA
Mellor, AC
Qualtrough, AJE
机构
[1] Univ Manchester, Sch Dent, Manchester M15 6FH, Lancs, England
[2] Dundee Dent Sch, Dept Restorat Dent, Dundee, Scotland
关键词
endodontic instruments; endodontics; sterilization; ultrasonic cleaners;
D O I
10.1111/j.1365-2591.2006.01058.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To assess whether pre-soaking files in an enzymatic cleaner prior to ultrasonic cleaning had any effect on cleanliness and also to assess the effect of the time that endodontic files spend in an ultrasonic bath prior to sterilization on their overall cleanliness. Twenty root canals in a total of ten patients were cleaned and shaped using conventional techniques. Following use, some of the files were pre-soaked and then ultrasonically cleaned for either 5, 10, 30 or 60 min. Other files had no pre-soaking and were then ultrasonically cleaned. There were two control groups, one where the files were pre-soaked and not ultrasonically cleaned and the other where the files were neither pre-soaked nor ultrasonically cleaned. All files were then subjected to a standard packing and autoclaving process. Following autoclaving, the files were examined using a light microscope at a magnification of 40x. The cutting section of each file was divided into two parts, the tip and the shaft, for visualization under the microscope. Any debris or cement on the files was scored using a modification of the scale used by Smith et al. (Journal of Hospital Infection, 51, 2002, 233). The data were analysed using one-way analysis of variance. Pre-soaking had no significant effect on the cleanliness of the files (P = 0.18 at the tip, P = 0.93 at the shaft). Ultrasonic cleaning had a significant effect on the cleanliness of the files (P < 0.00) but there was not a linear relationship between cleanliness and the ultrasonic cleaning time. There was little benefit in extending the ultrasonic cleaning time beyond 5 min. Calcium hydroxide deposits on two files were resistant to ultrasonic cleaning. There is no benefit in pre-soaking endodontic files prior to ultrasonic cleaning. The optimum time for ultrasonic cleaning was between 5 and 10 min. Further ultrasonic exposure, up to 60 min, did not improve cleanliness. Although a majority of files were free from debris following ultrasonic cleaning, a substantial minority still retained debris. This supports the case for endodontic files being single-use only.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 16 条
[1]  
Bebermeyer RD, 2003, QUINTESSENCE INT, V34, P38
[2]  
CAFRUNY WA, 1995, AM J DENT, V8, P152
[3]  
*DEP HLTH, 2003, TRANSM SPONG ENC AG
[4]   The transmissible spongiform encephalopathies (prion diseases): A review for dental surgeons [J].
Gill, DS ;
Tredwin, CJ ;
Gill, SK ;
Ironside, JW .
INTERNATIONAL DENTAL JOURNAL, 2001, 51 (06) :439-446
[5]   Dental instrument and device sterilization and disinfection practices [J].
Gurevich, I ;
Dubin, R ;
Cunha, BA .
JOURNAL OF HOSPITAL INFECTION, 1996, 32 (04) :295-304
[6]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[7]   Cleaning of rotary nickel-titanium endodontic instruments [J].
Linsuwanont, P ;
Parashos, P ;
Messer, HH .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (01) :19-28
[8]  
Miller C H, 1988, Gen Dent, V36, P31
[9]   CLEANING, STERILIZATION AND DISINFECTION - BASICS OF MICROBIAL KILLING FOR INFECTION CONTROL [J].
MILLER, CH .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1993, 124 (01) :48-56
[10]  
MURGEL CAF, 1990, J ENDODONT, V15, P214