Methacrylate-acrylate based polymers of low plasticiser content for potassium ion-selective membranes

被引:62
作者
Heng, LY [1 ]
Hall, EAH [1 ]
机构
[1] UNIV CAMBRIDGE,INST BIOTECHNOL,CAMBRIDGE CB2 1QT,ENGLAND
关键词
potassium ion-selective electrodes; methacrylate-acrylate polymers; plasticiser; valinomycin; anionic sites;
D O I
10.1016/0003-2670(96)00019-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polymers prepared from of glycidyl methacrylate, methyl methacrylate and n-butyl acrylate were studied for their possible use as a valinomycin-based potassium ion-selective membrane with low or no plasticiser content. Four polymers were observed to be functional as potassium ion-selective membranes in the presence of valinomycin and lipophilic salt. All polymeric membranes gave Nernstian or near-Nernstian responses over the potassium ion concentration range of 10(-5)-10(-1) M. The potassium selectivity over sodium, log K-KM(pot) values, for all membranes were in the range -3.0 to -4.1 as measured by the mixed solution method with interfering sodium ion at 0.1 M. Interference of Na+ and other cations was also studied by the separate solution method. Terpolymers prepared from methacrylate-acrylate monomers with a high n-butyl acrylate ratio, required little or no o-NPOE as plasticiser to form functional potassium ion-selective membranes with only a slight decrease in potassium ion selectivity. The monomer n-butyl acrylate appeared to act as a built-in plasticiser to lower the glass transition temperature of the polymers and allowed potassium ion-selective behaviour to occur even in the absence of plasticiser.
引用
收藏
页码:47 / 56
页数:10
相关论文
共 27 条
[1]  
AMMANN D, 1983, ION SEL ELECTRODE R, V5, P3
[2]  
BERG A, 1987, ANAL CHM, V59, P2827
[3]   ANION EFFECTS ON DONNAN FAILURE OF AMINATED-POLY(VINYL CHLORIDE)-BASED AND NEUTRAL-CARRIER-BASED PH SENSORS [J].
BUCK, RP ;
COSOFRET, VV ;
LINDNER, E .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :273-281
[4]   PHOTO-CURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES .3. A POTASSIUM ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
CARDWELL, TJ ;
CATTRALL, RW ;
ILES, PJ ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1988, 204 (1-2) :329-332
[5]  
*COMM AN NOM, 1976, PUR APPL CHEM, P129
[6]   MICROFABRICATED SENSOR ARRAYS SENSITIVE TO PH AND K+ FOR IONIC DISTRIBUTION MEASUREMENTS IN THE BEATING HEART [J].
COSOFRET, VV ;
ERDOSY, M ;
JOHNSON, TA ;
BUCK, RP ;
ASH, RB ;
NEUMAN, MR .
ANALYTICAL CHEMISTRY, 1995, 67 (10) :1647-1653
[7]   PVC MATRIX MEMBRANE ION-SELECTIVE ELECTRODES - CONSTRUCTION AND LABORATORY EXPERIMENTS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) :541-544
[8]   POTASSIUM ION-SELECTIVE ELECTRODES BASED ON VALINOMYCIN PVC OVERLAYERED SOLID SUBSTRATES [J].
DROR, M ;
BERGS, EA ;
RHODES, RK .
SENSORS AND ACTUATORS, 1987, 11 (01) :23-36
[9]  
EUSGTER R, 1994, ANAL CHIM ACTA, V289, P1
[10]   SELECTRODE - UNIVERSAL ION-SELECTIVE ELECTRODE .7. VALINOMYCIN-BASED POTASSIUM ELECTRODE WITH NONPOROUS POLYMER MEMBRANE AND SOLID-STATE INNER REFERENCE SYSTEM [J].
FIEDLER, U ;
RUZICKA, J .
ANALYTICA CHIMICA ACTA, 1973, 67 (01) :179-193