MICROFABRICATED SENSOR ARRAYS SENSITIVE TO PH AND K+ FOR IONIC DISTRIBUTION MEASUREMENTS IN THE BEATING HEART

被引:134
作者
COSOFRET, VV
ERDOSY, M
JOHNSON, TA
BUCK, RP
ASH, RB
NEUMAN, MR
机构
[1] UNIV N CAROLINA,DEPT CHEM,CHAPEL HILL,NC 27599
[2] UNIV N CAROLINA,DEPT MED,CHAPEL HILL,NC 27599
[3] N CAROLINA STATE UNIV,DEPT ELECT & COMP ENGN,RALEIGH,NC 27695
[4] CASE WESTERN RESERVE UNIV,METROHLTH MED CTR,DEPT OB GYN,CLEVELAND,OH 44109
关键词
D O I
10.1021/ac00106a001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thick-film H+- and K+-selective sensor arrays based on solvent polymeric neutral carrier membranes are described, The sensor away design and construction allow inexpensive and mass production of disposable miniaturized probes useful in the biomedical held, especially for cardiovascular research and monitoring. They are also suitable for use as multisensor electrochemical detectors within modern now injection analysis instrumentation. The carriers used for membrane preparation are H+-selective ETH 5294 chromoionophore and the well-known K+-selective ionophore, valinomycin. The preliminary in vivo experiments, to monitor H+ and K+ ionic distribution in the beating pig heart, help to determine the unique ionic conduction responsible for ventricullar fibrillation in the setting of acute regional myocardial ischemia.
引用
收藏
页码:1647 / 1653
页数:7
相关论文
共 40 条
  • [1] LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS
    AMMANN, D
    PRETSCH, E
    SIMON, W
    LINDNER, E
    BEZEGH, A
    PUNGOR, E
    [J]. ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) : 119 - 129
  • [2] BERGVELD P, 1988, WILSON WILSONS COMPR, V23
  • [3] EARLY CHANGES IN EXTRACELLULAR POTASSIUM IN ISCHEMIC RABBIT MYOCARDIUM - THE ROLE OF EXTRACELLULAR CARBON-DIOXIDE ACCUMULATION AND DIFFUSION
    CASCIO, WE
    YAN, GX
    KLEBER, AG
    [J]. CIRCULATION RESEARCH, 1992, 70 (02) : 409 - 422
  • [4] NEW NEUTRAL CARRIER-BASED H+ SELECTIVE-MEMBRANE ELECTRODES
    COSOFRET, VV
    NAHIR, TM
    LINDNER, E
    BUCK, RP
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 327 (1-2): : 137 - 146
  • [5] ION-SELECTIVE MICROCHEMICAL SENSORS WITH REDUCED PRECONDITIONING TIME - MEMBRANE BIOSTABILITY STUDIES AND APPLICATIONS IN BLOOD ANALYSIS
    COSOFRET, VV
    ERDOSY, M
    LINDNER, E
    JOHNSON, TA
    BUCK, RP
    KAO, WJ
    NEUMAN, MR
    ANDERSON, JM
    [J]. ANALYTICAL LETTERS, 1994, 27 (15) : 3039 - 3063
  • [6] CARBOXYLATED POLY(VINYL CHLORIDE) AS A SUBSTRATE FOR ION SENSORS - EFFECTS OF NATIVE ION-EXCHANGE ON RESPONSES
    COSOFRET, VV
    BUCK, RP
    ERDOSY, M
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (21) : 3592 - 3599
  • [7] DESIGN OF IONOPHORE-FREE H+-SELECTIVE SOLVENT POLYMERIC MEMBRANES FOR FURTHER BIOMEDICAL APPLICATIONS
    COSOFRET, VV
    LINDNER, E
    BUCK, RP
    KUSY, RP
    WHITLEY, JQ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 345 (1-2): : 169 - 181
  • [8] ELECTROANALYTICAL AND BIOCOMPATIBILITY STUDIES ON CARBOXYLATED POLY(VINYL CHLORIDE) MEMBRANES FOR MICROFABRICATED ARRAY SENSORS
    COSOFRET, VV
    ERDOSY, M
    BUCK, RP
    KAO, WJ
    ANDERSON, JM
    LINDNER, E
    NEUMAN, MR
    [J]. ANALYST, 1994, 119 (11) : 2283 - 2292
  • [9] PLANAR MICRO SENSORS FOR IN-VIVO MYOCARDIAL PH MEASUREMENTS
    COSOFRET, VV
    LINDNER, E
    JOHNSON, TA
    NEUMAN, MR
    [J]. TALANTA, 1994, 41 (06) : 931 - 938
  • [10] COSOFRET VV, IN PRESS POLM MATERI