ELECTROANALYTICAL AND BIOCOMPATIBILITY STUDIES ON CARBOXYLATED POLY(VINYL CHLORIDE) MEMBRANES FOR MICROFABRICATED ARRAY SENSORS

被引:47
作者
COSOFRET, VV
ERDOSY, M
BUCK, RP
KAO, WJ
ANDERSON, JM
LINDNER, E
NEUMAN, MR
机构
[1] UNIV N CAROLINA, DEPT CHEM, CHAPEL HILL, NC 27599 USA
[2] CASE WESTERN RESERVE UNIV, INST PATHOL, DEPT BIOMED ENGN, CLEVELAND, OH 44106 USA
[3] TECH UNIV BUDAPEST, INST GEN & ANALYT CHEM, H-1111 BUDAPEST, HUNGARY
[4] CASE WESTERN RESERVE UNIV, METROHLTH MED CTR, DEPT OBSTET & GYNECOL, CLEVELAND, OH 44109 USA
关键词
ION-SELECTIVE ELECTRODE; CARBOXYLATED POLY(VINYL CHLORIDE); REDUCED PLASTICIZER CONTENT; BIOCOMPATIBILITY;
D O I
10.1039/an9941902283
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potassium ion-selective and pH membrane electrodes based on neutral carrier ionophores for K+ (valinomycin) and H+ (TDDA and ETH 5294), respectively, immobilized in carboxylated PVC (PVC-COOH) with normal (classical) and reduced amounts of plasticizer, were investigated with respect to their general analytical performances (linear range, slope, detection limit, selectivity, internal membrane resistance), their biocompatibility and cellular responses. The analytical performance of potassium selective electrodes was not affected by reducing the plasticizer content from 66% (m/m) to about 33% (mim) while that of pH electrodes was significantly changed at the lower plasticizer concentration level. The adhesive properties of PVC-COOH membranes to an inert substrate such as polyimide-coated Kapton are greatly improved by reducing the plasticizer content of the membrane. In addition, as was reported earlier by this group, improved biocompatibility was observed with these membranes relative to those with increased plasticizer content. A ratio of 1:1 m/m for PVC-COOH to plasticizer is recommended for the construction of planar ISEs without massive use of internal solution.
引用
收藏
页码:2283 / 2292
页数:10
相关论文
共 37 条
[1]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[2]  
ANDERSON JM, 1988, ASAIO, V11, P101
[3]   ENZYME SENSORS BASED ON COATED-WIRE ELECTRODE - USE OF CARBOXYL-SUBSTITUTED POLYVINYL-CHLORIDE) AS A SUPPORT FOR IMMOBILIZING PENICILLINASE [J].
ANZAI, J ;
SHIMADA, M ;
OSA, T ;
CHEN, C .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1987, 60 (11) :4133-4137
[4]  
Bailey P.L., 1980, ANAL ION SELECTIVE E
[5]   EVIDENCE FOR A WATER-RICH SURFACE REGION IN POLY(VINYL CHLORIDE)-BASED ION-SELECTIVE ELECTRODE MEMBRANES [J].
CHAN, ADC ;
LI, XZ ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2512-2517
[6]   NEW NEUTRAL CARRIER-BASED H+ SELECTIVE-MEMBRANE ELECTRODES [J].
COSOFRET, VV ;
NAHIR, TM ;
LINDNER, E ;
BUCK, RP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 327 (1-2) :137-146
[7]   DESIGN OF IONOPHORE-FREE H+-SELECTIVE SOLVENT POLYMERIC MEMBRANES FOR FURTHER BIOMEDICAL APPLICATIONS [J].
COSOFRET, VV ;
LINDNER, E ;
BUCK, RP ;
KUSY, RP ;
WHITLEY, JQ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 345 (1-2) :169-181
[8]   PLANAR MICRO SENSORS FOR IN-VIVO MYOCARDIAL PH MEASUREMENTS [J].
COSOFRET, VV ;
LINDNER, E ;
JOHNSON, TA ;
NEUMAN, MR .
TALANTA, 1994, 41 (06) :931-938
[9]  
COSOFRET VV, IN PRESS ANAL CHEM
[10]   ELIMINATION OF THE ASYMMETRY IN NEUTRAL-CARRIER-BASED SOLVENT POLYMERIC MEMBRANES INDUCED BY PROTEINS [J].
DURSELEN, LFJ ;
WEGMANN, D ;
MAY, K ;
OESCH, U ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1455-1458