Assessment of different fluorimetric reactions for cyanide determination in flow systems

被引:38
作者
Miralles, E
Prat, D
Compano, R
Granados, M
机构
[1] Departament de Química Analítica, Universitat de Barcelona, E-08028 Barcelona
关键词
cyanide; flow injection analysis; fluorimetry;
D O I
10.1039/a608422b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several fluorimetric reactions for the determination of cyanide by means of flow injection systems were tested, The first reaction is based on the displacement of 8-hydroxyquinoline-5-sulfonic acid (HQS) from the Pd(HQS)(2) complex by cyanide ion and the subsequent reaction of free HQS with Mg-II to form a fluorescent species, Secondly, the inhibitory effect of cyanide on the reaction between iodine and fluorescein was also evaluated as a method to quantify cyanide, The third method is based on the detection of an isoindole derivative formed by the reaction of o-phthalaldehyde (OPA) or 2,3-naphthalenedialdehyde (NDA) with glycine in the presence of cyanide, Chemical and hydrodynamic parameters mere optimized for each system and the analytical performance of the methods was established, Detection limits of 5 mu g l(-1) (fluorescein-iodine method), 0.40 mu g l(-1) (Pd-HQS-Mg method), 0.25 mu g l(-1) (OPA method) and 0.03 mu g l(-1) (NDA method) were obtained.
引用
收藏
页码:553 / 558
页数:6
相关论文
共 22 条
[1]  
[Anonymous], STAND METH EX WAT WA
[2]  
ASTM, 1979, ANN BOOK ASTM STA 23
[3]  
BOX GEP, 1978, STATISTICS EXPT
[4]   FLOW-THROUGH SENSOR FOR THE FLUOROMETRIC-DETERMINATION OF CYANIDE [J].
CHEN, DH ;
DECASTRO, MDL ;
VALCARCEL, M .
TALANTA, 1990, 37 (11) :1049-1055
[5]   NAPHTHALENE-2,3-DICARBOXALDEHYDE CYANIDE ION - A RATIONALLY DESIGNED FLUOROGENIC REAGENT FOR PRIMARY AMINES [J].
DEMONTIGNY, P ;
STOBAUGH, JF ;
GIVENS, RS ;
CARLSON, RG ;
SRINIVASACHAR, K ;
STERNSON, LA ;
HIGUCHI, T .
ANALYTICAL CHEMISTRY, 1987, 59 (08) :1096-1101
[6]   REMOVAL OF INTERFERENCES IN THE SPECTROPHOTOMETRIC DETERMINATION OF CYANIDE BY DIALYSIS USING FLOW-INJECTION ANALYSIS [J].
FIGUEROLA, E ;
FLORIDO, A ;
AGUILAR, M ;
DEPABLO, J .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 331 (06) :620-622
[7]   POSTCOLUMN LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF CYANIDE WITH FLUOROMETRIC DETECTION [J].
GAMOH, K ;
IMAMICHI, S .
ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) :255-259
[8]  
GUOQUAN G, 1994, ANAL LETT, V27, P2797
[9]   FLUOROMETRIC AND COLORIMETRIC ESTIMATION OF CYANIDE AND SULFIDE BY DEMASKING REACTIONS OF PALLADIUM CHELATES [J].
HANKER, JS ;
GELBERG, A ;
WITTEN, B .
ANALYTICAL CHEMISTRY, 1958, 30 (01) :93-95
[10]   GAS PERMEATION AND PRECONCENTRATION IN THE FLOW-INJECTION DETERMINATION OF ACID-AVAILABLE CYANIDE IN WASTE-WATER [J].
KUBAN, V .
ANALYTICA CHIMICA ACTA, 1992, 259 (01) :45-52