Advances in proteomics data analysis and display using an accurate mass and time tag approach

被引:261
作者
Zimmer, JSD
Monroe, ME
Qian, WJ
Smith, RD
机构
[1] Pacific NW Natl Lab, Div Biol Sci, Richland, WA 99352 USA
[2] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
FTICR-MS; proteomics; AMT tag; SPICAT; QCET; PhIST;
D O I
10.1002/mas.20071
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Proteomics has recently demonstrated utility for increasing the understanding of cellular processes on the molecular level as a component of systems biology approaches and for identifying potential biomarkers of various disease states. The large amount of data generated by utilizing high efficiency (e.g., chromatographic) separations coupled with high mass accuracy mass spectrometry for high-throughput proteomics analyses presents challenges related to data processing, analysis, and display. This review focuses on recent advances in nanoLC-FTICR-MS-based proteomics approaches and the accompanying data processing tools that have been developed to display and interpret the large volumes of data being produced. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:450 / 482
页数:33
相关论文
共 139 条
[1]   Chemical strategies for functional proteomics [J].
Adam, GC ;
Sorensen, EJ ;
Cravatt, BF .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (10) :781-790
[2]   Mass spectrometry in proteomics [J].
Aebersold, R ;
Goodlett, DR .
CHEMICAL REVIEWS, 2001, 101 (02) :269-295
[3]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[4]  
ANDERSON KK, 2004, ESTIMATING PROBABILI
[5]   ISOLATION OF PHOSPHOPROTEINS BY IMMOBILIZED METAL (FE-3+) AFFINITY-CHROMATOGRAPHY [J].
ANDERSSON, L ;
PORATH, J .
ANALYTICAL BIOCHEMISTRY, 1986, 154 (01) :250-254
[6]  
Belov ME, 2000, J AM SOC MASS SPECTR, V11, P19, DOI 10.1016/S1044-0305(99)00121-X
[7]   Zeptomole-sensitivity electrospray ionization - Fourier transform ion cyclotron resonance mass spectrometry of proteins [J].
Belov, ME ;
Gorshkov, MV ;
Udseth, HR ;
Anderson, GA ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2271-2279
[8]   Initial implementation, of external accumulation liquid chromatography/electrospray ionization Fourier transform ion cyclotron resonance with automated gain control [J].
Belov, ME ;
Rakov, VS ;
Nikolaev, EN ;
Goshe, MB ;
Anderson, GA ;
Smith, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (07) :627-636
[9]   Dynamic range expansion applied to mass spectrometry based on data-dependent selective ion ejection in capillary liquid chromatography Fourier transform ion cyclotron resonance for enhanced proteome characterization [J].
Belov, ME ;
Anderson, GA ;
Angell, NH ;
Shen, YF ;
Tolic, N ;
Udseth, HR ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5052-5060
[10]   Ion discrimination during ion accumulation in a quadrupole interface external to a Fourier transform ion cyclotron resonance mass spectrometer [J].
Belov, ME ;
Nikolaev, EN ;
Harkewicz, R ;
Masselon, CD ;
Alving, K ;
Smith, RD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) :205-225