摘要
A sequential ion-sensing system using a single microchip was successfully realized. The system developed here involves intermittent pumping of plural organic phases into a microchannel, followed by contact with a single aqueous phase to form a stable organic-aqueous two-layer flow inside the microchannel. Because the plural organic phases created by intermittent flow contain the same lipophilic pH indicator dye but different ion-selective neutral ionophores, different ions can be sequentially and selectively extracted into the different organic phases, where they can be determined by thermal lens microscopy (TLM). We used KD-A3 as the lipophilic pH indicator dye and valinomycin and DD16C5 as neutral ionophores to demonstrate sequential ion sensing of potassium and sodium ions by measuring the deprotonated dye caused by the ion extraction. The integrated microfluidic system proposed here allows multi-ion sensing, which is not easily demonstrated by conventional ion sensor technology using a solvent polymeric membrane. The minimum volume of single organic phase needed to obtain an equilibrium response without dilution by cross dispersion of two organic phases was ca. 500 nL in our system, indicating that the required amounts of expensive reagents in one measurement could be reduced to 1.7 ng and 2.8 ng for the dye and ionophore molecules, respectively.
引用
收藏
页码:5551 / 5556
页数:6
相关论文
共 27 条
[1]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[2]  
Ehrfeld W., 2000, Microreactors: new technology for modern chemistry, DOI DOI 10.1002/3527601953
[3]  
Freemantle M, 1999, CHEM ENG NEWS, V77, P27, DOI 10.1021/cen-v077n044.p027
[4]   Integrated multilayer flow system on a microchip [J].
Hibara, A ;
Tokeshi, M ;
Uchiyama, K ;
Hisamoto, H ;
Kitamori, T .
ANALYTICAL SCIENCES, 2001, 17 (01) :89-93
[5]  
HISAMOTO H, 1995, SENSOR ACTUAT B-CHEM, V29, P378, DOI 10.1016/0925-4005(95)01711-9
[6]   Theory and practice of rapid flow-through analysis based on ion-selective optode detection and its application to sodium ion determination [J].
Hisamoto, H ;
Satoh, S ;
Satoh, K ;
Tsubuku, M ;
Siswanta, D ;
Shichi, Y ;
Koike, Y ;
Suzuki, K .
ANALYTICA CHIMICA ACTA, 1999, 396 (2-3) :131-141
[7]   Ion-sensitive and selective active waveguide optodes [J].
Hisamoto, H ;
Kim, KH ;
Manabe, Y ;
Sasaki, K ;
Minamitani, H ;
Suzuki, K .
ANALYTICA CHIMICA ACTA, 1997, 342 (01) :31-39
[8]   On-chip integration of neutral ionophore-based ion pair extraction reaction [J].
Hisamoto, H ;
Horiuchi, T ;
Tokeshi, M ;
Hibara, A ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1382-1386
[9]   Quantitative analysis of molecular interaction in a microfluidic channel: The T-sensor [J].
Kamholz, AE ;
Weigl, BH ;
Finlayson, BA ;
Yager, P .
ANALYTICAL CHEMISTRY, 1999, 71 (23) :5340-5347
[10]   Fabrication inside microchannels using fluid flow [J].
Kenis, PJA ;
Ismagilov, RF ;
Takayama, S ;
Whitesides, GM ;
Li, SL ;
White, HS .
ACCOUNTS OF CHEMICAL RESEARCH, 2000, 33 (12) :841-847