Theory and practice of rapid flow-through analysis based on ion-selective optode detection and its application to sodium ion determination

被引:12
作者
Hisamoto, H
Satoh, S
Satoh, K
Tsubuku, M
Siswanta, D
Shichi, Y
Koike, Y
Suzuki, K
机构
[1] Keio Univ, Dept Appl Chem, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
[2] Nissan ARK Ltd, Dept Res, Surface Anal Sect, Yokosuka, Kanagawa 2370061, Japan
[3] Kanagawa Acad Sci & Technol, Takatsu Ku, Kawasaki, Kanagawa 2130012, Japan
关键词
chemical sensor; flow-analysis; ionophore; ion-selective optode; ion sensor;
D O I
10.1016/S0003-2670(99)00482-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One simple example of a rapid flow-through analysis (RFA) system,based on-ion-selective optode detection was demonstrated, and its performance was discussed. The RFA is a flow analytical method based on a reagentless analyte flow injection system combined with an analyte selective monitor/sensor such as an optical chemical sensor (optode) involving mathematical response simulation using a semi-empirical theoretical response equation. The response of RFA with optode detection can basically be expressed by the equation derived from Fick's law of diffusion and Kubelka-Munk's law, and two other variable parameters in relation to the experimental response. Mathematically simulated results using the proposed equation indicated that the equation can be useful for the prediction of the flow analytical response. In the present demonstration of RFA, highly selective ionophores based on 16-crown-5 derivatives were used for the ion-sensing component of the optode for sodium ion determination. A sodium ion-selective optode based on C14-DD16C5 and KD-A3 exhibited high selectivity for sodium ion over potassium ion, with a selectivity coefficient (log K-i.j(opt)) of -2.6. This optode responded to sodium ion in the concentration range from 10(-5) to 10(-1) M at pH 8.0 by measuring the absorbance Change at 510 nn in the sensing phase of the optode. The RFA system equipped with a sodium ion-selective optode offers a reagent-less advanced ion-determination methodology for Conventional flow injection analysis. (C)1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:131 / 141
页数:11
相关论文
共 22 条
  • [1] LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS
    DINTEN, O
    SPICHIGER, UE
    CHANIOTAKIS, N
    GEHRIG, P
    RUSTERHOLZ, B
    MORF, WE
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (06) : 596 - 603
  • [2] FLOW-INJECTION ANALYSIS WITH BULK EXTRACTION BASED OPTICAL SENSOR MEMBRANES
    HAUSER, PC
    LITTEN, JC
    [J]. ANALYTICA CHIMICA ACTA, 1994, 294 (01) : 49 - 56
  • [3] FLOW-THROUGH TYPE CHLORIDE-ION SELECTIVE OPTODES BASED ON LIPOPHILIC ORGANOMETALLIC CHLORIDE ADDUCTS AND A LIPOPHILIC ANIONIC DYE
    HISAMOTO, H
    WATANABE, K
    OKA, H
    NAKAGAWA, E
    SPICHIGER, UE
    SUZUKI, K
    [J]. ANALYTICAL SCIENCES, 1994, 10 (04) : 615 - 622
  • [4] Theory and practice of rapid flow-through analysis based on optode detection and its application to pH measurement as a model case
    Hisamoto, H
    Tsubuku, M
    Enomoto, T
    Watanabe, K
    Kawaguchi, H
    Koike, Y
    Suzuki, K
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (21) : 3871 - 3878
  • [5] SILVER ION-SELECTIVE OPTODES BASED ON NOVEL THIA ETHER COMPOUNDS
    HISAMOTO, H
    NAKAGAWA, E
    NAGATSUKA, K
    ABE, Y
    SATO, S
    SISWANTA, D
    SUZUKI, K
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (08) : 1315 - 1321
  • [6] FLOW-THROUGH TYPE CALCIUM-ION SELECTIVE OPTODES BASED ON NOVEL NEUTRAL IONOPHORES AND A LIPOPHILIC ANIONIC DYE
    HISAMOTO, H
    WATANABE, K
    NAKAGAWA, E
    SISWANTA, D
    SHICHI, Y
    SUZUKI, K
    [J]. ANALYTICA CHIMICA ACTA, 1994, 299 (02) : 179 - 187
  • [7] POLYMERIC MEMBRANE SODIUM-SELECTIVE ELECTRODES BASED ON LIPOPHILIC CALIX[4]ARENE DERIVATIVES
    KIMURA, K
    MIURA, T
    MATSUO, M
    SHONO, T
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (14) : 1510 - 1513
  • [8] DYNAMIC-MODEL OF AN OPTICAL ABSORPTION-BASED PH SENSOR
    KOSTOV, Y
    TZONKOV, S
    YOTOVA, L
    [J]. ANALYST, 1993, 118 (08) : 987 - 990
  • [9] Kubelka P., 1931, Z. Tech. Phys, V12, P593
  • [10] LIFE TIME OF NEUTRAL CARRIER BASED ION-SELECTIVE LIQUID-MEMBRANE ELECTRODES
    OESCH, U
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (04) : 692 - 700