Experimental design optimization of solid-phase microextraction conditions for the determination of heterocyclic aromatic amines by high-performance liquid chromatography

被引:20
作者
Cárdenes, L [1 ]
Martín-Calero, A [1 ]
Ayala, JH [1 ]
González, V [1 ]
Afonso, AM [1 ]
机构
[1] Univ La Laguna, Dept Analyt Chem Nutr & Food Sci, E-38205 San Cristobal la Laguna, Spain
关键词
solid-phase microextraction; high-performance liquid chromatography; optimization; heterocyclic aromatic amines; food analysis;
D O I
10.1080/00032710500477217
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid-phase microextraction, using Carbowax-Templated Resin fiber, coupled with high performance liquid chromatography ultra violet/diode array detector (HPLC-UV/DAD) has been optimized for the determination of the heterocyclic aromatic amines (HAs). Three variables (absorption time, soaking time, and desorption time) were considered as factors in the optimization process. Interactions between analytical factors and their optimal levels were investigated using two level factorial and Doehlert matrix designs. Absorption time and soaking time were significant variables, and 15 min for each one of the variables was chosen for the best response. The optimized procedure allowed the determination of HAs with detection limits that ranged from 1.58 to 16.8 ng/L (except PhIP: 23.8 ng/L). The reproducibility of the method (n=5), expressed as relative standard deviation was between 2.21% and 28.3%. The method was applied to the analysis of a meat extract sample and the range of recoveries for the amines was 64.14%-112.72%.
引用
收藏
页码:405 / 423
页数:19
相关论文
共 44 条
[1]   Optimization of solid-phase microextraction conditions using a response surface methodology to determine organochlorine pesticides in water by gas chromatography and electron-capture detection [J].
Aguilar, C ;
Peñalver, A ;
Pocurull, E ;
Ferré, J ;
Borrull, F ;
Marcé, RM .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :425-432
[2]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[3]   Evaluation of reversed-phase columns for the analysis of heterocyclic aromatic amines by liquid chromatography -: electrospray mass spectrometry [J].
Barceló-Barrachina, E ;
Moyano, E ;
Puignou, L ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (01) :45-59
[4]   Evaluation of different liquid chromatography-electrospray mass spectrometry systems for the analysis of heterocyclic amines [J].
Barceló-Barrachina, E ;
Moyano, E ;
Puignou, L ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1023 (01) :67-78
[5]   Experimental designs applied to solid-phase derivative spectrophotometry [J].
Bosque-Sendra, JM ;
Nechar, M ;
Molina, MF .
MIKROCHIMICA ACTA, 2000, 134 (1-2) :43-50
[6]   OPTIMIZATION OF ANALYTICAL METHODS BY USING DOEHLERTS DESIGNS [J].
BOSQUESENDRA, JM ;
NECHAR, M ;
RODRIGUEZ, LC ;
MOLINA, MFM .
ANALYTICAL PROCEEDINGS, 1995, 32 (09) :375-377
[7]   Solid-phase microextraction coupled with high-performance liquid chromatography for the analysis of heterocyclic aromatic amines [J].
Cárdenes, L ;
Ayala, JH ;
Afonso, AM ;
González, V .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1030 (1-2) :87-93
[8]   Analysis of carcinogenic aromatic amines in water samples by solid-phase microextraction coupled with high-performance liquid chromatography [J].
Chang, WY ;
Sung, YH ;
Huang, SD .
ANALYTICA CHIMICA ACTA, 2003, 495 (1-2) :109-122
[9]   SOLID-PHASE MICROEXTRACTION COUPLED TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHEN, J ;
PAWLISZYN, JB .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2530-2533
[10]   Optimisation of the extraction of arsenic species from mussels with low power focused microwaves by applying a Doehlert design [J].
Dagnac, T ;
Padró, A ;
Rubio, R ;
Rauret, G .
ANALYTICA CHIMICA ACTA, 1998, 364 (1-3) :19-30