Polymerase chain reaction/ligase detection reaction/hybridization assays using flow-through microfluidic devices for the detection of low-abundant DNA point mutations

被引:109
作者
Hashimoto, M
Barany, F
Soper, SA [1 ]
机构
[1] Louisiana State Univ, Ctr Biomodular Multiscale Syst, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
[3] Cornell Univ, Dept Microbiol, Weill Med Coll, New York, NY 10021 USA
关键词
DNA diagnostics; microfluidics; ligase detection reaction; DNA microarrays;
D O I
10.1016/j.bios.2006.01.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We have microfabricated a flow-through biochip for the analysis of single base mutations in genomic DNA using two different materials: (1) a polycarbonate (PC) chip for performing a primary polymerase chain reaction (PCR) followed by an allele-specific ligation detection reaction (LDR) and (2) a poly(methyl methacrylate) (PMMA) chip for the detection of the LDR products using a universal array platform. The operation of the device was demonstrated by detecting low-abundant DNA mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. The PC microchip was used for sequential PCR/LDR in a continuous-flow format, in which the following three steps were carried out: (1) exponential amplification of gene fragments from genomic DNA; (2) mixing of the resultant PCR product with a LDR mixture via a Y-shaped passive micromixer and (3) ligation of two primers only when the particular mutation was present in the genomic DNA. A PMMA chip was employed as the microarray device, where zip code sequences (24-mer), which were complementary to sequences present on the discriminating primer, were micro-printed into fluidic channels embossed into the PMMA substrate. We successfully demonstrate the ability to detect one mutant DNA in 80 normal sequences with the integrated microfluidic device. The PCR/LDR/hybridization assay using the microchips performed the entire assay at a relatively fast processing speed: 18.7 min for PCR, 8.1 min for LDR, 5 min for hybridization, 10 min for washing and 2.6 min for fluorescence scanning (total processing time = ca. 50 min) with an order of magnitude reduction in reagents compared to bench-top formats. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1915 / 1923
页数:9
相关论文
共 24 条
  • [1] K-ras mutations and prognosis in large-bowel carcinomas
    Andersen, SN
    Lovig, T
    Breivik, J
    Lund, E
    Gaudernack, G
    Meling, GI
    Rognum, TO
    [J]. SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1997, 32 (01) : 62 - 69
  • [3] Microfabricated structures for integrated DNA analysis
    Burns, MA
    Mastrangelo, CH
    Sammarco, TS
    Man, FP
    Webster, JR
    Johnson, BN
    Foerster, B
    Jones, D
    Fields, Y
    Kaiser, AR
    Burke, DT
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (11) : 5556 - 5561
  • [4] Role of K-ras mutations in colorectal carcinoma
    Chiang, JM
    [J]. CANCER LETTERS, 1998, 126 (02) : 179 - 185
  • [5] Detection and quantification of mutations in the plasma of patients with colorectal tumors
    Diehl, F
    Li, M
    Dressman, D
    He, YP
    Shen, D
    Szabo, S
    Diaz, LA
    Goodman, SN
    David, KA
    Juhl, H
    Kinzler, KW
    Vogelstein, B
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (45) : 16368 - 16373
  • [6] Universal DNA array detection of small insertions and deletions in BRCA1 and BRCA2
    Favis, R
    Day, JP
    Gerry, NP
    Phelan, C
    Narod, S
    Barany, F
    [J]. NATURE BIOTECHNOLOGY, 2000, 18 (05) : 561 - 564
  • [7] Universal DNA microarray method for multiplex detection of low abundance point mutations
    Gerry, NP
    Witowski, NE
    Day, J
    Hammer, RP
    Barany, G
    Barany, F
    [J]. JOURNAL OF MOLECULAR BIOLOGY, 1999, 292 (02) : 251 - 262
  • [8] Ligase detection reaction/hybridization assays using three-dimensional microfluidic networks for the detection of low-abundant DNA point mutations
    Hashimoto, M
    Hupert, ML
    Murphy, MC
    Soper, SA
    Cheng, YW
    Barany, F
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (10) : 3243 - 3255
  • [9] Rapid PCR in a continuous flow device
    Hashimoto, M
    Chen, PC
    Mitchell, MW
    Nikitopoulos, DE
    Soper, SA
    Murphy, MC
    [J]. LAB ON A CHIP, 2004, 4 (06): : 638 - 645
  • [10] Surface modification of poly(methyl methacrylate) used in the fabrication of microanalytical devices
    Henry, AC
    Tutt, TJ
    Galloway, M
    Davidson, YY
    McWhorter, CS
    Soper, SA
    McCarley, RL
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (21) : 5331 - 5337