Polymerase chain reaction/ligase detection reaction/hybridization assays using flow-through microfluidic devices for the detection of low-abundant DNA point mutations

被引:109
作者
Hashimoto, M
Barany, F
Soper, SA [1 ]
机构
[1] Louisiana State Univ, Ctr Biomodular Multiscale Syst, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
[3] Cornell Univ, Dept Microbiol, Weill Med Coll, New York, NY 10021 USA
关键词
DNA diagnostics; microfluidics; ligase detection reaction; DNA microarrays;
D O I
10.1016/j.bios.2006.01.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We have microfabricated a flow-through biochip for the analysis of single base mutations in genomic DNA using two different materials: (1) a polycarbonate (PC) chip for performing a primary polymerase chain reaction (PCR) followed by an allele-specific ligation detection reaction (LDR) and (2) a poly(methyl methacrylate) (PMMA) chip for the detection of the LDR products using a universal array platform. The operation of the device was demonstrated by detecting low-abundant DNA mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. The PC microchip was used for sequential PCR/LDR in a continuous-flow format, in which the following three steps were carried out: (1) exponential amplification of gene fragments from genomic DNA; (2) mixing of the resultant PCR product with a LDR mixture via a Y-shaped passive micromixer and (3) ligation of two primers only when the particular mutation was present in the genomic DNA. A PMMA chip was employed as the microarray device, where zip code sequences (24-mer), which were complementary to sequences present on the discriminating primer, were micro-printed into fluidic channels embossed into the PMMA substrate. We successfully demonstrate the ability to detect one mutant DNA in 80 normal sequences with the integrated microfluidic device. The PCR/LDR/hybridization assay using the microchips performed the entire assay at a relatively fast processing speed: 18.7 min for PCR, 8.1 min for LDR, 5 min for hybridization, 10 min for washing and 2.6 min for fluorescence scanning (total processing time = ca. 50 min) with an order of magnitude reduction in reagents compared to bench-top formats. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1915 / 1923
页数:9
相关论文
共 24 条
  • [21] 2-9
  • [22] High-resolution near-infrared imaging of DNA microarrays with time-resolved acquisition of fluorescence lifetimes
    Waddell, E
    Wang, Y
    Stryjewski, W
    McWhorter, S
    Henry, AC
    Evans, D
    McCarley, RL
    Soper, SA
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (24) : 5907 - 5917
  • [23] Microarrays assembled in microfluidic chips fabricated from poly(methyl methacrylate) for the detection of low-abundant DNA mutations
    Wang, Y
    Vaidya, B
    Farquar, HD
    Stryjewski, W
    Hammer, RP
    McCarley, RL
    Soper, SA
    Cheng, YW
    Barany, F
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (05) : 1130 - 1140
  • [24] Solid-phase reversible immobilization in microfluidic chips for the purification of dye-labeled DNA sequencing fragments
    Xu, YC
    Vaidya, B
    Patel, AB
    Ford, SM
    McCarley, RL
    Soper, SA
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (13) : 2975 - 2984