Comparison of traditional cloud-point extraction and on-line flow-injection cloud-point extraction with a chemiluminescence method using benzo[a]pyrene as a marker

被引:24
作者
Song, GQ
Lu, C
Hayakawa, K
Lin, JM
机构
[1] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, State Key Lab Environm Chem & Ecotoxicol, Beijing 100085, Peoples R China
[2] Kanazawa Univ, Fac Pharmaceut Sci, Grad Sch Nat Sci & Technol, Kanazawa, Ishikawa 9201192, Japan
基金
中国国家自然科学基金;
关键词
on-line flow-injection cloud-point extraction; traditional cloud-point extraction; chemiluminescence; benzo(a)pyrene;
D O I
10.1007/s00216-005-0224-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, using benzo(a)pyrene (BaP) as marker, the analytical merits of on-line flow-injection cloud-point extraction (FI CPE), including preconcentration factor, extraction efficiency, sample throughput, and analysis time were evaluated by use of peroxyoxalate chemiluminescence (CL) detection. Moreover, by detailed discussion of several preconcentration conditions for traditional and on-line FI CPE the advantages of on-line FI CPE became conspicuously apparent. When coupled with separation techniques such as high-performance liquid chromatography (HPLC) or capillary electrophoresis (CE), on-line FI CPE-CL has much potential for analysis of low concentrations of polycyclic aromatic hydrocarbons (PAH) in environmental samples.
引用
收藏
页码:1007 / 1012
页数:6
相关论文
共 20 条
[1]   MICELLAR-ENHANCED AQUEOUS PEROXYOXALATE CHEMILUMINESCENCE [J].
DAN, N ;
LAU, ML ;
GRAYESKI, ML .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1766-1771
[2]   Nonionic surfactant mixtures:: a new cloud-point extraction approach for the determination of PAHs in seawater using HPLC with fluorimetric detection [J].
Delgado, B ;
Pino, V ;
Ayala, JH ;
González, V ;
Afonso, AM .
ANALYTICA CHIMICA ACTA, 2004, 518 (1-2) :165-172
[3]   Online incorporation of cloud point extraction to flow injection analysis [J].
Fang, Q ;
Du, M ;
Huie, CW .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3502-3505
[4]   The use of micellar systems in the extraction and pre-concentration of organic pollutants in environmental samples [J].
Ferrera, ZS ;
Sanz, CP ;
Santana, CM ;
Rodríguez, JJS .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (07) :469-479
[5]   Cloud-point extraction/preconcentration on-line flow injection method for mercury determination [J].
Garrido, M ;
Di Nezio, MS ;
Lista, AG ;
Palomeque, M ;
Band, BSF .
ANALYTICA CHIMICA ACTA, 2004, 502 (02) :173-177
[6]   CLOUDING OF TRITON-X-114 - THE EFFECT OF ADDED ELECTROLYTES ON THE CLOUD POINT OF TRITON-X-114 IN THE PRESENCE OF IONIC SURFACTANTS [J].
GU, T ;
GALERAGOMEZ, PA .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1995, 104 (2-3) :307-312
[7]   SCREENING OF URINARY COPROPORPHYRIN USING CLOUD POINT EXTRACTION AND CHEMILUMINESCENCE DETECTION [J].
HORVATH, WJ ;
HUIE, CW .
TALANTA, 1993, 40 (09) :1385-1390
[8]  
HORYATH WJ, 1992, TALANTA, V39, P487
[9]   STABILITY OF BIS(2,4,6-TRICHLOROPHENYL) OXALATE IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR CHEMI-LUMINESCENCE DETECTION [J].
IMAIZUMI, N ;
HAYAKAWA, K ;
MIYAZAKI, M ;
IMAI, K .
ANALYST, 1989, 114 (02) :161-164
[10]   MICELLE-MEDIATED METHODOLOGY FOR THE PRECONCENTRATION OF URANIUM PRIOR TO ITS DETERMINATION BY FLOW-INJECTION [J].
LAESPADA, MEF ;
PAVON, JLP ;
CORDERO, BM .
ANALYST, 1993, 118 (02) :209-212