Labeling digoxin antibody with colloidal gold and ferrocene for its use in a membrane immunostrip and immunosensor

被引:12
作者
Choi, MJ
Kim, SY
Choi, J
Paeng, IR
机构
[1] Korea Inst Sci & Technol, Bioanal & Biotransformat Res Ctr, Seoul 130650, South Korea
[2] Seoul Womens Univ, Dept Chem, Seoul 139774, South Korea
关键词
digoxin; enzyme immunoassay; immunochromatography; immunosensor;
D O I
10.1006/mchj.1999.1770
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Current trends in the development of on-site diagnostic tests using immunodetection principles are proceeding in two directions: toward the immunochromatography test strip and toward the immunosensor. To develop both applications for the detection of digoxin, we prepared multilabeled antibody conjugates using colloidal gold and ferrocene. Prior to applying the digoxin antibody in immunochromatography, we constructed a dose-response curve with the digoxin antibody by enzyme immunoassay under optimized conditions. From the results, we found it was possible to detect as little as 10(-5) mu g/ml (1.28 x 10(-11) M) digoxin, which is within the therapeutic and toxic ranges of digoxin. First, this antibody was labeled with ferrocene as a sensor signal generator. As the ferrocene moiety increased, electroactivity also increased, but immunoreactivity between digoxin and its antibody was constant as ascertained from the molar ratio of its conjugate which was up to 1:35. And the immunoreactivity of the conjugate with molar ratio 1:125 dropped by 50%. Thus, after determining the optimum molar ratio (1:35) of antibody to ferrocene, this ferrocene-conjugated antibody was labeled with colloidal gold for the visual recognition of color in the strip. This immunostrip could detect a digoxin level of 1 mu g/ml (1.28 x 10(-6) M) within 2 min. (C) 1999 Academic Press.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 11 条
[1]  
BUTLER VP, 1982, METHODS ENZYMOLOGY, V84
[2]   The optimization of ELISA for methamphetamine determination: The effect of immunogen, tracer and antibody purification method on the sensitivity [J].
Choi, J ;
Choi, MJ ;
Kim, C ;
Cho, YS ;
Chin, J ;
Jo, YA .
ARCHIVES OF PHARMACAL RESEARCH, 1997, 20 (01) :46-52
[3]   HETEROGENEOUS IMMUNOASSAY FOR SERUM-PROTEINS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
DOYLE, MJ ;
HALSALL, HB ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2318-2322
[4]  
GOSLING JP, 1997, PRINCIPLES PRACTICE, P351
[5]   Studies towards a disposable screen-printed amperometric biosensor for progesterone [J].
Hart, JP ;
Pemberton, RM ;
Luxton, R ;
Wedge, R .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (11) :1113-1121
[6]   EXTENDING THE DETECTION LIMIT OF SOLID-PHASE ELECTROCHEMICAL ENZYME-IMMUNOASSAY TO THE ATTOMOLE LEVEL [J].
JENKINS, SH ;
HEINEMAN, WR ;
HALSALL, HB .
ANALYTICAL BIOCHEMISTRY, 1988, 168 (02) :292-299
[7]  
KABAKOFF DS, 1980, ENZYME IMMUNOASSAY, P71
[8]   HOMOGENEOUS ASSAYS FOR RIBOFLAVIN MEDIATED BY THE INTERACTION BETWEEN ENZYME-BIOTIN AND AVIDIN-RIBOFLAVIN CONJUGATES [J].
KIM, MJ ;
KIM, HJ ;
KIM, JM ;
KIM, B ;
HAN, SH ;
CHA, GS .
ANALYTICAL BIOCHEMISTRY, 1995, 231 (02) :400-406
[9]  
PRICE CP, 1997, PRINCIPLES PRACTICE, P3
[10]   MULTILABELING OF FERROCENES TO A GLUCOSE-OXIDASE DIGOXIN CONJUGATE FOR THE DEVELOPMENT OF A HOMOGENEOUS ELECTROENZYMATIC IMMUNOASSAY [J].
SUZAWA, T ;
IKARIYAMA, Y ;
AIZAWA, M .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :3889-3894