Dispersion effects in partial coherence interferometry: Implications for intraocular ranging

被引:111
作者
Hitzenberger, CK [1 ]
Baumgartner, A [1 ]
Drexler, W [1 ]
Fercher, AF [1 ]
机构
[1] Univ Vienna, Inst Med Phys, A-1090 Vienna, Austria
关键词
partial coherence interferometry; optical coherence tomography; dispersion; dispersion compensation eye; ocular media;
D O I
10.1117/1.429900
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
hn nondispersive media, the minimum distance that can be resolved by partial coherence interferometry (PCI) and optical coherence tomography (OCT) is inversely proportional to the source spectral bandwidth. Dispersion tends to increase the signal width and to degrade the resolution. We analyze the situation for PCI ranging and OCT imaging of ocular structures. It can be shown that for each ocular segment an optimum source bandwidth yielding optimum resolution exists. if the resolution is to be improved beyond this point, the group dispersion of the ocular media has to be compensated. With the use of a dispersion compensating element, and employing a broadband superluminescent diode, we demonstrate a resolution of 5 mu m in the retina of both a model eye and a human eye in vivo. This is an improvement by a factor of 2-3 as compared to currently used instruments. (C) 1999 Society of Photo-Optical Instrumentation Engineers. [S1083-3668(99)00701-7].
引用
收藏
页码:144 / 151
页数:8
相关论文
共 30 条
[1]  
*AM NAT STAND I, 1986, 1361 ANSI Z
[2]   Measurements of the posterior structures of the human eye in vivo by partial coherence interferometry using diffractive optics [J].
Baumgartner, A ;
Moller, B ;
Hitzenberger, CK ;
Drexler, W ;
Fercher, AF .
COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS, PROCEEDINGS OF, 1997, 2981 :85-93
[3]  
Born M., 1987, Principles of Optics
[4]   HIGH-RESOLUTION OPTICAL COHERENCE TOMOGRAPHIC IMAGING USING A MODE-LOCKED TI-AL2O3 LASER SOURCE [J].
BOUMA, B ;
TEARNEY, GJ ;
BOPPART, SA ;
HEE, MR ;
BREZINSKI, ME ;
FUJIMOTO, JG .
OPTICS LETTERS, 1995, 20 (13) :1486-1488
[5]   HIGH-RESOLUTION OCDR IN DISPERSIVE WAVE-GUIDES [J].
BRINKMEYER, E ;
ULRICH, R .
ELECTRONICS LETTERS, 1990, 26 (06) :413-414
[6]  
CLIVAZ X, 1994, P SOC PHOTO-OPT INS, V2083, P338, DOI 10.1117/12.167408
[7]   ABSOLUTE OPTICAL RANGING USING LOW COHERENCE INTERFEROMETRY [J].
DANIELSON, BL ;
BOISROBERT, CY .
APPLIED OPTICS, 1991, 30 (21) :2975-2979
[8]   CHROMATIC DISPERSION EFFECTS IN COHERENT ABSOLUTE RANGING [J].
DEGROOT, P .
OPTICS LETTERS, 1992, 17 (12) :898-900
[9]   Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry [J].
Drexler, W ;
Hitzenberger, CK ;
Baumgartner, A ;
Findl, O ;
Sattmann, H ;
Fercher, AF .
EXPERIMENTAL EYE RESEARCH, 1998, 66 (01) :25-33
[10]  
Drexler W, 1997, INVEST OPHTH VIS SCI, V38, P1304