Comparison of Macular Thickness Between Cirrus HD-OCT and Stratus OCT

被引:62
作者
Kakinoki, Masashi [1 ]
Sawada, Osamu [1 ]
Sawada, Tomoko [1 ]
Kawamura, Hajime [1 ]
Ohji, Masahito [1 ]
机构
[1] Shiga Univ Med Sci, Dept Ophthalmol, Otsu, Shiga 5202192, Japan
关键词
OPTICAL COHERENCE TOMOGRAPHY; RETINAL THICKNESS; INTRAVITREAL INJECTION; BEVACIZUMAB AVASTIN(R); DIABETIC-RETINOPATHY; ANALYZER; DEGENERATION; EDEMA;
D O I
10.3928/15428877-20090301-09
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE:To compare macular thicknesses in healthy subjects measured with spectral domain optical coherence tomography (SD-OCT) (Cirrus; Carl Zeiss Meditec, Inc., Dublin, CA) with measurements using time domain (TD-OCT) (Stratus; Carl Zeiss Meditec, Inc.). PATIENTS AND METHODS: Macular thickness was measured five times in the same eye of 10 healthy subjects with both Cirrus and Stratus to assess reliability and then once in the same eye of 50 healthy subjects with both Cirrus and Stratus to compare the average obtained by each device. RESULTS: Using TD-OCT, the coefficient of variations (CV) of the macular thicknesses within a 1-mm central area ranged from 0.7% to 3.3% (mean, 1.33%); with SD-OCT, the range was 0.2% to 1.3% (mean, 0.66%). The mean CV with SD-OCT was significantly smaller than with TD-OCT (P < .05). The average macular thicknesses with TD-OCT and SD-OCT were 197.2 +/- 17.8 mu m and 257.6 +/- 19.6 mu m, respectively. However, the correlation was significant (correlation coefficient, 0.916, P < .001). CONCLUSION: Cirrus showed better reliability than Stratus. Using SD-OCT, the macula was 60-mu m thicker than when measured with TD-OCT. Attention should be given to comparing data obtained using different OCT machines. [Ophthalmic Surg Lasers Imaging 2009;40:135-140.]
引用
收藏
页码:135 / 140
页数:6
相关论文
共 19 条
[1]   Optical coherence tomography study of optic disc melanocytoma [J].
Chaudhary, R ;
Arora, R ;
Mehta, DK ;
Singh, M .
OPHTHALMIC SURGERY LASERS & IMAGING, 2006, 37 (01) :58-61
[2]   Retinal thickness in diabetic retinopathy - Comparison of optical coherence tomography, the retinal thickness analyzer, and fundus photography [J].
Goebel, W ;
Franke, R .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2006, 26 (01) :49-57
[3]   Optical coherence tomography in group 2A idiopathic juxtafoveolar telangiectasis [J].
Gupta, V ;
Gupta, A ;
Dogra, MR ;
Agarwal, A .
OPHTHALMIC SURGERY LASERS & IMAGING, 2005, 36 (06) :482-486
[4]  
HAGIMURA N, 1998, JPN J CLIN OPHTHAL, V52, P385
[5]   Diagnosis of macular pseudoholes and lamellar macular holes by optical coherence tomography [J].
Haouchine, B ;
Massin, P ;
Tadayoni, R ;
Erginay, A ;
Gaudric, A .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (05) :732-739
[6]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[7]   Evaluation of central serous chorioretinopathy with optical coherence tomography [J].
Iida, T ;
Hagimura, N ;
Sato, T ;
Kishi, S .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (01) :16-20
[8]   Optical coherence tomography of orange-red subretinal lesions in eyes with idiopathic polypoidal choroidal vasculopathy [J].
Iijima, H ;
Iida, T ;
Imai, M ;
Gohdo, T ;
Tsukahara, S .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (01) :21-26
[9]   Optical coherence tomography to detect and manage retinal disease and glaucoma [J].
Jaffe, GJ ;
Caprioli, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (01) :156-169
[10]  
Kanai Kaname, 2002, Nippon Ganka Gakkai Zasshi, V106, P162