摘要
Background. During the past 2 years, the development of a totally implantable biventricular bypass rotary blood pump system has been made. Methods. An extracorporeal gyro centrifugal pump, the CIE3, was miniaturized and developed into the PI601, a totally implantable plastic pump. Two-day anatomic and hemodynamic feasibility studies demonstrated that these two pump systems were easily implantable inside a calf's abdominal wall, directly under the diaphragm. The priming volume of the pump was 20 mt, with sufficient cardiac outputs at approximately 2,000 rpm and requiring less than 10 W of power. Two-week antithrombogenic screening tests also revealed these pump systems to be quite antithrombogenic. In addition, 1-month system reliability studies demonstrated fail-safe reliable performances. Results and Conclusions. Encouraged by these preliminary studies, the PI601 model was converted to the permanently implantable titanium gyro pump PI702 model. The long-term implantations were initiated approximately 3 months ago, and two such long-term LVAD studies are currently underway with no sign of difficulty (October 10, 1997). They were followed 283 days and 72 days, respectively. Both terminated due to functional inflow obstruction. There were no blood clots or emboli at autopsy. (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:775 / 779
页数:5
相关论文
共 20 条
[1]   Cost analysis of the Novacor Left Ventricular Assist System as an outpatient bridge to heart transplantation [J].
Arabia, FA ;
Smith, RG ;
Jaffe, C ;
Wild, JC ;
Rose, DS ;
Nelson, RJ ;
McClellan, DM ;
Acuna, GA ;
Edling, NG ;
Harrington, NK ;
Rabago, G ;
Tsen, AC ;
Arzouman, DA ;
Sethi, GK ;
Copeland, JG .
ASAIO JOURNAL, 1996, 42 (05) :M546-M549
[2]  
Ashton RC, 1996, J HEART LUNG TRANSPL, V15, P1151
[3]   The CardioWest total artificial heart bridge to transplantation:: 1993 to 1996 national trial [J].
Copeland, JG ;
Arabía, FA ;
Banchy, ME ;
Sethi, GK ;
Foy, B ;
Long, J ;
Kormos, RL ;
Smith, RG .
ANNALS OF THORACIC SURGERY, 1998, 66 (05) :1662-1669
[4]   MULTICENTER CLINICAL-EVALUATION OF THE HEARTMATE 1000-IP LEFT-VENTRICULAR ASSIST DEVICE [J].
FRAZIER, OH ;
ROSE, EA ;
MACMANUS, Q ;
BURTON, NA ;
LEFRAK, EA ;
POIRIER, VL ;
DASSE, KA .
ANNALS OF THORACIC SURGERY, 1992, 53 (06) :1080-1090
[5]   Improved left ventricular function after chronic left ventricular unloading [J].
Frazier, OH ;
Benedict, CR ;
Radovancevic, B ;
Bick, RJ ;
Capek, P ;
Springer, WE ;
Macris, MP ;
Delgado, R ;
Buja, LM .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :675-681
[6]   APPLICATION OF ENZYME IMMUNOASSAYS FOR TESTING HEMOCOMPATIBILITY OF BIOMEDICAL POLYMERS [J].
GROTH, T ;
CAMPBELL, EJ ;
HERRMANN, K ;
SEIFERT, B .
BIOMATERIALS, 1995, 16 (13) :1009-1015
[7]  
HARASAKI H, 1979, T AM SOC ART INT ORG, V25, P225
[8]   Ex vivo phase 1 evaluation of the DeBakey NASA axial flow ventricular assist device [J].
Kawahito, K ;
Damm, G ;
Benkowski, R ;
Aber, G ;
Bacak, J ;
Tasai, K ;
Shimono, T ;
Takatani, S ;
Nose, Y ;
Noon, GP ;
DeBakey, ME .
ARTIFICIAL ORGANS, 1996, 20 (01) :47-52
[9]   LDL-apheresis atherosclerosis regression study (LAARS) - Effect of aggressive versus conventional lipid lowering treatment on coronary atherosclerosis [J].
Kroon, AA ;
Aengevaeren, WRM ;
vanderWerf, T ;
Uijen, GJH ;
Reiber, JHC ;
Bruschke, AVG ;
Stalenhoef, AFH .
CIRCULATION, 1996, 93 (10) :1826-1835
[10]   INTERNAL HYDRAULIC LOSS IN A SEALLESS CENTRIFUGAL GYRO PUMP [J].
MAKINOUCHI, K ;
OHARA, Y ;
SAKUMA, I ;
DAMM, G ;
MIZUGUCHI, K ;
JIKUYA, T ;
TAKATANI, S ;
NOON, GP ;
NOSE, Y .
ARTIFICIAL ORGANS, 1994, 18 (01) :25-31