Use of a priori information in estimating tissue resistivities-application to measured data

被引:5
作者
Baysal, U
Eyüboglu, BM [1 ]
机构
[1] Middle E Tech Univ, Dept Elect & Elect Engn, TR-06531 Ankara, Turkey
[2] Hacettepe Univ, Dept Elect & Elect Engn, Biomed Engn Lab, TR-06532 Ankara, Turkey
关键词
D O I
10.1088/0031-9155/44/7/308
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A statistically constrained minimum mean squares error estimator (MiMSEE) has been shown to be useful in estimating internal resistivity distribution by the use of simulated data. In this study, the performance of the MiMSEE algorithm is tested by using measured data from resistor phantoms. The MiMSEE uses a priori information on body geometry, electrode position, statistical properties of tissue resistivities, instrumentation noise and linearization error to calculate the optimum inverse matrix which maps the surface potentials to unknown regional resistivities. In this study, the MiMSEE is also constrained with the variance-covariance of the modelling error to improve the estimation accuracy. The data are obtained from two different phantom geometries, namely five-region and thorax. Using the measured data, the estimations are realized and errors are calculated. Then, the results are compared with the results obtained by using a conventional least squares error estimator (LSEE). The five-region model results show similarity with the simulation study results of Baysal and Eyuboglu. On the thorax model, the total estimation error is 34.2% with the MiMSEE compared with 856% with the LSEE. It is concluded that the MiMSEE is more robust than the LSEE and applicable to measured data.
引用
收藏
页码:1677 / 1689
页数:13
相关论文
共 9 条
[1]   Use of a priori information in estimating tissue resistivities -: a simulation study [J].
Baysal, U ;
Eyüboglu, BM .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12) :3589-3606
[2]   Imaging with electricity: Report of the European Concerted Action on Impedance Tomography [J].
Boone, K ;
Barber, D ;
Brown, B .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1997, 21 (06) :201-232
[3]   ESTIMATION OF TISSUE RESISTIVITIES FROM MULTIPLE-ELECTRODE IMPEDANCE MEASUREMENTS [J].
EYUBOGLU, BM ;
PILKINGTON, TC ;
WOLF, PD .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (01) :1-17
[4]   A phantom for electrical impedance tomography [J].
Griffiths, H. .
Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A) :15-20
[5]   A METHOD FOR COMPARATIVE-EVALUATION OF EIT ALGORITHMS USING A STANDARD DATA SET [J].
IDER, YZ ;
EYUBOGLU, BM ;
KUZUOGLU, M ;
LEBLEBICIOGLU, K ;
BAYSAL, U ;
CAGLAR, BK ;
BIRGUL, O .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 :A227-A236
[6]  
KNEPPO P, 1992, CRIT REV BIOMED ENG, V19, P343
[7]   DETERMINATION OF OPTIMUM INJECTED CURRENT PATTERNS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY [J].
KOKSAL, A ;
EYUBOGLU, BM .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 :A99-A109
[8]  
MILLER CE, 1990, CRIT REV BIOMED ENG, V18, P207
[9]   MULTIFREQUENCY ELECTRICAL-IMPEDANCE TOMOGRAPHY [J].
RECORD, PM ;
GADD, R ;
VINTHER, F .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 :67-72