Assessing glycemia in diabetes using self-monitoring blood glucose and hemoglobin A1c

被引:260
作者
Saudek, CD [1 ]
Derr, RL [1 ]
Kalyani, RR [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Med, Div Endocrinol & Metab, Baltimore, MD 21205 USA
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 2006年 / 295卷 / 14期
关键词
D O I
10.1001/jama.295.14.1688
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context With the increasing prevalence of diabetes, successful management of blood glucose control is increasingly important. Current approaches to assessing glycemia include the use of self-monitoring of blood glucose (SMBG) and hemoglobin A(1c) (HbA(1c)). Objectives To assess the evidence underlying the use of these 2 modalities, to evaluate confounders and sources of error in each test, to describe upcoming developments, and to reach evidence-based conclusions on their optimal use. Data Sources, Study Selection, and Data Extraction Reports identified from MEDLINE searches (1976-2005) using relevant terms were selected for quality and relevance to the stated questions. Particular attention was paid to larger cohort studies, clinical trials, meta-analyses, and established recommendations. Data Synthesis If used properly SMBG gives an acceptably accurate reflection of immediate plasma glucose levels. Study results vary, but in general, the evidence supports a positive effect of regular SMBG for improving glycemia, particularly in individuals treated with insulin. The best timing of SMBG and its frequency are controversial issues, but the clinical recommendation is for regular monitoring with frequency depending on the treatment and the instability of glycemia. In the relatively near term, SMBG could gradually be replaced by continuous glucose monitoring. HbA(1c) measures long-term glycemic control, reflecting a time-weighted mean over the previous 3 to 4 months. There are a number of physiologic and methodologic confounders that can affect HbA(1c), but standardization of assays has been well established. The main value of HbA(1c) is its use as a predictor of diabetic complications and the proven effect of improved control of HbA(1c) on complication risk. A reasonable target value for HbA(1c) is less than 7%. A new method for measuring HbA(1c) may cause significant changes in the recommended levels, the numbers reported, and even the name of the test. Conclusion Assessing glycemia in diabetes can be a challenge, but approaches are available that promote successful management of blood glucose and may thereby lead to a significant reduction in morbidity and mortality related to diabetes.
引用
收藏
页码:1688 / 1697
页数:10
相关论文
共 117 条
[1]   Association of systolic blood pressure with macrovascular and microvascular complications of type 2 diabetes (UKPDS 36): prospective observational study [J].
Adler, AI ;
Stratton, IM ;
Neil, HAW ;
Yudkin, JS ;
Matthews, DR ;
Cull, CA ;
Wright, AD ;
Turner, RC ;
Holman, RR .
BMJ-BRITISH MEDICAL JOURNAL, 2000, 321 (7258) :412-419
[2]   IMPACT OF GLUCOSE SELF-MONITORING ON NON-INSULIN-TREATED PATIENTS WITH TYPE-II DIABETES-MELLITUS - RANDOMIZED CONTROLLED TRIAL COMPARING BLOOD AND URINE TESTING [J].
ALLEN, BT ;
DELONG, ER ;
FEUSSNER, JR .
DIABETES CARE, 1990, 13 (10) :1044-1050
[3]  
American Diabetes Association, 2001, Diabetes Care, V24, P775
[4]  
[Anonymous], 2005, DIABETES CARE, V28, pS4
[5]   Hypoglycemia in the diabetes control and complications trial [J].
不详 .
DIABETES, 1997, 46 (02) :271-286
[6]  
[Anonymous], 1996, DIABETES, V45, P1289
[7]  
[Anonymous], 1995, DIABETES, V44, P968
[8]   Tests of glycemia for the diagnosis of type 2 diabetes mellitus [J].
Barr, RG ;
Nathan, DM ;
Meigs, JB ;
Singer, DE .
ANNALS OF INTERNAL MEDICINE, 2002, 137 (04) :263-272
[9]   Identifying variables associated with inaccurate self-monitoring of blood glucose: Proposed guidelines to improve accuracy [J].
Bergenstal, R ;
Pearson, J ;
Cembrowski, GS ;
Bina, D ;
Davidson, J ;
List, S .
DIABETES EDUCATOR, 2000, 26 (06) :981-989
[10]   Clinical impact of prandial state, exercise, and site preparation on the equivalence of alternative-site blood glucose testing [J].
Bina, DM ;
Anderson, RL ;
Johnson, ML ;
Bergenstal, RM ;
Kendall, DM .
DIABETES CARE, 2003, 26 (04) :981-985