Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia

被引:127
作者
Harvitt, DM [1 ]
Bonanno, JA [1 ]
机构
[1] Univ Calif Berkeley, Sch Optometry, Vis Sci Grp, Berkeley, CA 94720 USA
关键词
contact lens; oxygen; oxygen transmissibility (Dk/t); acidosis; model; phosphorescence; cornea; extended wear;
D O I
10.1097/00006324-199910000-00023
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose: (1) To update Fatt's mathematical model of the distribution of oxygen tension (po,) across the cornea and contact lens (CL) to include the recent finding that corneal oxygen consumption increases with the acidification that occurs with CL wear. (2) To estimate the minimum transmissibility (CL Dk/t) to avoid epithelial anoxia or to avoid stromal anoxia. Methods: A five-layer static and one-dimensional mathematical model of oxygen diffusion through the cornea based on Fatt's models was used. The relationships between acidosis and increased Qo(2), and acidosis and CL Dk/t were used to estimate corneal QO(2) for a given CL Dk/t. Results: (1) Revised model predictions are in agreement with direct tear po, measurements beneath CLs in the rabbit. (2) For the human eye, the minimum CL Dk/t for oxygen delivery to the basal epithelial cells was determined to be 23 for the open eye and 89 for the closed eye. To prevent anoxia throughout the entire corneal thickness the Dk/t requirements are 35 for the open eye and 125 for the closed eye. Conclusions: (1) Model predictions of the oxygen distribution beneath contact lenses are significantly lower than previous models that did not include the effect of acidosis on corneal QO(2). (2) Minimum Dk/t values that allow oxygen delivery to the basal epithelium are in agreement with the Dk/t needed to avoid corneal edema.
引用
收藏
页码:712 / 719
页数:8
相关论文
共 46 条
[1]
Oxygen permeability of a new type of high Dk soft contact lens material [J].
Alvord, L ;
Court, J ;
Davis, T ;
Morgan, CF ;
Schindhelm, K ;
Vogt, J ;
Winterton, L .
OPTOMETRY AND VISION SCIENCE, 1998, 75 (01) :30-36
[2]
BALABAN RS, 1990, AM J PHYSIOL, V258, P377
[3]
BONANNO JA, 1987, OPHTHALMOLOGY, V94, P1305
[4]
BRENNAN NA, 1988, AM J OPTOM PHYS OPT, V65, P19
[5]
Distribution of oxygen across the surface of the human cornea during soft contact lens wear [J].
Efron, N ;
Fitzgerald, JP .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (10) :659-665
[6]
EFRON N, 1981, AM J OPTOM PHYS OPT, V58, P806
[7]
OXYGEN-TENSION DISTRIBUTIONS IN CORNEA - RE-EXAMINATION [J].
FATT, I ;
FREEMAN, RD ;
LIN, D .
EXPERIMENTAL EYE RESEARCH, 1974, 18 (04) :357-365
[8]
STEADY-STATE DISTRIBUTION OF OXYGEN AND CARBON DIOXIDE IN IN VIVO CORNEA .I. OPEN EYE IN AIR AND CLOSED EYE [J].
FATT, I ;
BIEBER, MT .
EXPERIMENTAL EYE RESEARCH, 1968, 7 (01) :103-&
[10]
FATT I, 1969, AMER J OPT ARCH AM A, V46, P3