Four-angle saturation transfer (FAST) method for measuring creatine kinase reaction rates in vivo

被引:69
作者
Bottomley, PA
Ouwerkerk, R
Lee, RF
Weiss, RG
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Sch Med, Dept Med, Baltimore, MD 21205 USA
关键词
saturation transfer; reaction rates; creatine kinase; high-energy phosphate; energy metabolism;
D O I
10.1002/mrm.10130
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new fast method of measuring kinetic reaction rates for two-site chemical exchange is described. The method employs saturation transfer magnetic resonance spectroscopy (MRS) and acquisition of only four spectra under partially saturated, high signal-to-noise ratio (SNR) conditions. In two acquisitions one of the exchanging species is saturated; the other two employ a control saturation. Each pair of acquisitions is applied with two different flip angles, and the equilibrium magnetization, relaxation times, and reaction rates are calculated therefrom. This four-angle saturation transfer (FAST) method is validated theoretically using the Bloch equations modified for two-state chemical exchange. Potential errors in the rate measurements due to the effects of exchange are evaluated for creatine kinase (CK) metabolism modeled for skeletal and heart muscle, and are found to be <5% for forward CK flux rates of 0.05 less than or equal to k(f) less than or equal to 1.0 s(-1), and up to a 90% depletion of phosphocreatine (PCr). The effect of too much or too little saturating irradiation on FAST appears to be comparable to that of the conventional saturation transfer method, although the relative performance deteriorates when spillover irradiation cuts the PCr signal by 50% or more. "FASTer" and "FASTest" protocols are introduced for dynamic CK studies wherein [PCr] and/or kf changes. These protocols permit the omission of one or two of the four acquisitions in repeat experiments, and the missing information is recreated from initial data via a new iterative algorithm. The FAST method is validated empirically in phosphorus P-31) MRS studies of human calf muscle at 1.5 T. FAST measurements of 10 normal volunteers yielded the same CK reaction nates measured by the conventional method (0,29 h 0.06 s(-1)) in the same subjects, but an average of seven times faster. Application of the FASTer algorithm to these data correctly restored missing information within seven iterations. Finally, the FAST method was combined with ID spatially localized P-31 MRS in a study of six volunteers, yielding the same k(f) values independent of depth, in total acquisition times of 17-39 min. These timesaving FAST methods are enabling because they permit localized measurements of metabolic flux, which were previously impractical due to intolerably long scan times, (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:850 / 863
页数:14
相关论文
共 41 条
[1]   Off-resonance irradiation effect in steady-state NMR saturation transfer [J].
Baguet, E ;
Roby, C .
JOURNAL OF MAGNETIC RESONANCE, 1997, 128 (02) :149-160
[2]   RATE-EQUATION FOR CREATINE-KINASE PREDICTS THE INVIVO REACTION VELOCITY - P-31 NMR SURFACE COIL STUDIES IN BRAIN, HEART, AND SKELETAL-MUSCLE OF THE LIVING RAT [J].
BITTL, JA ;
DELAYRE, J ;
INGWALL, JS .
BIOCHEMISTRY, 1987, 26 (19) :6083-6090
[3]   BIRP, AN IMPROVED IMPLEMENTATION OF LOW-ANGLE ADIABATIC (BIR-4) EXCITATION PULSES [J].
BOTTOMLEY, PA ;
OUWERKERK, R .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 103 (02) :242-244
[4]   MAPPING CREATINE-KINASE REACTION-RATES IN HUMAN BRAIN AND HEART WITH 4-TESLA SATURATION TRANSFER P-31 NMR [J].
BOTTOMLEY, PA ;
HARDY, CJ .
JOURNAL OF MAGNETIC RESONANCE, 1992, 99 (02) :443-448
[5]   Non-invasive magnetic-resonance detection of creatine depletion in non-viable infarcted myocardium [J].
Bottomley, PA ;
Weiss, RG .
LANCET, 1998, 351 (9104) :714-718
[6]   Total creatine in muscle: Imaging and quantification with proton MR spectroscopy [J].
Bottomley, PA ;
Lee, YH ;
Weiss, RG .
RADIOLOGY, 1997, 204 (02) :403-410
[7]   Human cardiac high-energy phosphate metabolite concentrations by 1D-resolved NMR spectroscopy [J].
Bottomley, PA ;
Atalar, E ;
Weiss, RG .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :664-670
[8]   OPTIMUM FLIP-ANGLES FOR EXCITING NMR WITH UNCERTAIN T-1 VALUES [J].
BOTTOMLEY, PA ;
OUWERKERK, R .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (01) :137-141
[9]  
BOTTOMLEY PA, 1989, CLIN CHEM, V35, P392
[10]   THE DUAL-ANGLE METHOD FOR FAST, SENSITIVE T-1 MEASUREMENT IN-VIVO WITH LOW-ANGLE ADIABATIC PULSES [J].
BOTTOMLEY, PA ;
OUWERKERK, R .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 104 (02) :159-167