Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays

被引:194
作者
Chaibi, Y. [1 ,2 ]
Cresson, T. [2 ]
Aubert, B. [1 ]
Hausselle, J. [1 ]
Neyret, P. [3 ]
Hauger, O. [4 ]
de Guise, J. A. [2 ]
Skalli, W. [1 ]
机构
[1] Arts & Metiers ParisTech, CNRS, LBM, Paris, France
[2] LIO, ETS, Ctr Rech CHUM, Montreal, PQ, Canada
[3] Hosp Civils Lyon, Hop Croix Rousse, Dept Orthopaed Surg, Ctr Albert Trillat, Lyon, France
[4] CHU Bordeaux, Hop Pellegrin, Unite Imagerie Osteoarticulaire, Bordeaux, France
关键词
biplanar X-rays; lower limb; 3D modelling; clinical 3D measurements; parametric model; statistical inferences; TOTAL KNEE ARTHROPLASTY; LOWER-EXTREMITY; TIBIAL TORSION; FEMORAL ANTEVERSION; FUNCTIONAL AXES; AXIAL ALIGNMENT; PROXIMAL FEMUR; ROTATION; POSITION; SYSTEM;
D O I
10.1080/10255842.2010.540758
中图分类号
TP39 [计算机的应用];
学科分类号
080201 [机械制造及其自动化];
摘要
In clinical routine, lower limb analysis relies on conventional X-ray (2D view) or computerised tomography (CT) Scan (lying position). However, these methods do not allow 3D analysis in standing position. The aim of this study is to propose a fast and accurate 3D-reconstruction-method based on parametric models and statistical inferences from biplanar X-rays with clinical measurements' (CM) assessment in standing position for a clinical routine use. For the reproducibility study, the 95% CI was under 2.7 degrees for all lower limbs' angular measurements except for tibial torsion, femoral torsion and tibiofemoral rotation (< 5 degrees). The 95% CI were under 2.5mm for lower limbs' lengths and 1.5 to 3 degrees for the pelvis' CM. Comparisons between X-rays and CT-scan based 3D shapes in vitro showed mean differences of 1.0mm (95% CI 2.4 mm). Comparisons of 2D lower limbs' and 3D pelvis' CM between standing 'Shifted-Feet' and 'Non-Shifted-Feet' position showed means differences of 0.0 to 1.4 degrees. Significant differences were found only for pelvic obliquity and rotation. The reconstruction time was about 5 min.
引用
收藏
页码:457 / 466
页数:10
相关论文
共 46 条
[1]
Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity [J].
Baudoin, A. ;
Skalli, W. ;
De Guise, J. A. ;
Mitton, D. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (08) :799-805
[2]
Baudoin A, 2008, THESIS ECOLE NATL SU
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
A QUANTITATIVE APPROACH TO RADIOGRAPHY OF THE LOWER-LIMB - PRINCIPLES AND APPLICATIONS [J].
COOKE, TDV ;
SCUDAMORE, RA ;
BRYANT, JT ;
SORBIE, C ;
SIU, D ;
FISHER, B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :715-720
[5]
Cresson T, 2008, 30 ANN INT C IEEE EM
[6]
De Momi E, 2006, P 6 ANN M CAOS INT M
[7]
Deltour F, 1998, CAHIERS ENSEIGNEMENT
[8]
Automatic extraction of proximal femur contours from calibrated X-ray images using 3D statistical models: an in vitro study [J].
Dong, Xiao ;
Zheng, Guoyan .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (02) :213-222
[9]
A new 2D and 3D imaging approach to musculo-skeletal physiology and pathology with low-dose radiation and the standing position : the EOS system [J].
Dubousset, J ;
Charpak, G ;
Dorion, I ;
Skalli, W ;
Lavaste, F ;
Deguise, J ;
Kalifa, G ;
Ferey, S .
BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2005, 189 (02) :287-297
[10]
Dubousset J, 2005, B ACAD NATL MED, V189, P297