Silica-based hybrid materials as biocompatible coatings for glucose sensors

被引:75
作者
Kros, A
Gerritsen, M
Sprakel, VSI
Sommerdijk, NAJM
Jansen, JA
Nolte, RJM
机构
[1] Eindhoven Univ Technol, Lab Macromol & Organ Chem, NL-5600 MB Eindhoven, Netherlands
[2] Univ Nijmegen, Dept Organ Chem, Nijmegen, Netherlands
[3] Univ Nijmegen, Dept Biomat, Nijmegen, Netherlands
关键词
sol-gel; silica; biocompatibility; amperometric biosensor; glucose oxidase; glucose;
D O I
10.1016/S0925-4005(01)00933-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preparation of sol-gel silica-based biocompatible coatings, which can be used for future implantable glucose sensors is described. Tetraethylorthosilicate (TEOS) was used as precursor for water-borne silicate gels of which the properties were varied by mixing the sol with polyethylene glycol (SG-PEG), heparin (SG-HEP), dextran sulfate (SG-DS), nafion (SG-NAF) or polystyrene sulfonate (SG-PSS). The toxicity of the coatings was examined in vitro using human dermal fibroblasts. All materials showed to be non-toxic and the cell proliferation rate of fibroblasts was found to be dependent on the additive. Glucose measurements using glucose oxidase-based sensors coated with the different hybrid films were performed both in buffered solutions containing bovine serum albumin and in serum. Stable glucose responses were obtained for the coated sensors in both media. The SG-DS containing coating appeared to be most promising for future in vivo glucose measurements. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:68 / 75
页数:8
相关论文
共 46 条
[1]  
[Anonymous], ANGEW CHEM
[2]   ENZYMES AND OTHER PROTEINS ENTRAPPED IN SOL-GEL MATERIALS [J].
AVNIR, D ;
BRAUN, S ;
LEV, O ;
OTTOLENGHI, M .
CHEMISTRY OF MATERIALS, 1994, 6 (10) :1605-1614
[3]   ORGANIC-CHEMISTRY WITHIN CERAMIC MATRICES - DOPED SOL-GEL MATERIALS [J].
AVNIR, D .
ACCOUNTS OF CHEMICAL RESEARCH, 1995, 28 (08) :328-334
[4]  
CAMMANN K, 1991, ANGEW CHEM, V103, P519
[5]   Stability of oxidases immobilized in silica gels [J].
Chen, Q ;
Kenausis, GL ;
Heller, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (19) :4582-4585
[6]   CONTACT-ANGLE MEASUREMENTS ON HUMAN-ENAMEL - AN INVITRO STUDY OF INFLUENCE OF PELLICLE AND STORAGE PERIOD [J].
DEJONG, HP ;
VANPELT, AWJ ;
ARENDS, J .
JOURNAL OF DENTAL RESEARCH, 1982, 61 (01) :11-13
[7]  
Eggins B.R., 1996, Biosensors: an Introduction
[8]   ENCAPSULATION OF PROTEINS IN TRANSPARENT POROUS SILICATE-GLASSES PREPARED BY THE SOL-GEL METHOD [J].
ELLERBY, LM ;
NISHIDA, CR ;
NISHIDA, F ;
YAMANAKA, SA ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
SCIENCE, 1992, 255 (5048) :1113-1115
[9]   Calcification-resistant nafion/Fe3+ assemblies for implantable biosensors [J].
Galeska, I ;
Chattopadhyay, D ;
Moussy, F ;
Papadimitrakopoulos, F .
BIOMACROMOLECULES, 2000, 1 (02) :202-207
[10]   Performance of subcutaneously implanted glucose sensors: A review [J].
Gerritsen, M ;
Jansen, JA ;
Kros, A ;
Nolte, RJM ;
Lutterman, JA .
JOURNAL OF INVESTIGATIVE SURGERY, 1998, 11 (03) :163-174