Cement augmentation of intertrochanteric fracture fixation - A cadaver comparison of 2 techniques

被引:20
作者
Choueka, J
Koval, KJ
Kummer, FJ
Zuckerman, JD
机构
[1] HOSP JOINT DIS & MED CTR, INST ORTHOPAED, DEPT ORTHOPAED SURG, NEW YORK, NY 10003 USA
[2] HOSP JOINT DIS & MED CTR, INST ORTHOPAED, DEPT BIOENGN, NEW YORK, NY 10003 USA
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1996年 / 67卷 / 02期
关键词
D O I
10.3109/17453679608994661
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We evaluated 2 techniques of cement augmentation to enhance fixation of intertrochanteric hip fractures. 4 fixation groups with 6 cadaver femurs in each group were compared: stainless steel lag screw and side plate with and without cement augmentation and a titanium alloy expandable dome plunger and side plate with and without cement augmentation. Gauges were used to establish the mechanical behavior of intact and then fractured femurs to simple uniaxial loads. Subsequent loading to failure allowed determination of maximum fixation strengths and modes of failure. Cement augmentation of each device increased its load to failure. There was no significant difference between the cemented lag screw and the uncemented dome plunger groups with average loads to failure of 4.0 x 10(3) N. The greatest average load to failure was in the cemented dome plunger group (5.6 x 10(3) N) with the lowest in the uncemented sliding hip screw group (3.6 x 10(3) N). Device cut-out as a cause of failure occurred mostly in the uncemented lag screw group. Sliding was enhanced by those methods that increased the fixation surface area within the femoral head, unless cement encroached in the region of the barrel-screw junction. Strain analysis showed that the dome plunger unloaded the bone at the calcar, regardless of cement augmentation, while the sliding hip screw allowed for compressive stresses in this area. Proper cement augmentation increases load to failure and minimizes nail cut-out for both devices studied. However, the dome plunger, a device with a large fixation area in the femoral head, was equally effective and eliminated potential cement encroachment. failure of intertrochanteric fracture fixation in osteoporotic bone may be minimized by an appropriate choice of device or cement augmentation.
引用
收藏
页码:153 / 157
页数:5
相关论文
共 16 条
  • [1] THE EFFECT OF ADJUNCTIVE METHYLMETHACRYLATE ON FAILURES OF FIXATION AND FUNCTION IN PATIENTS WITH INTERTROCHANTERIC FRACTURES AND OSTEOPOROSIS
    BARTUCCI, EJ
    GONZALEZ, MH
    COOPERMAN, DR
    FREEDBERG, HI
    BARMADA, R
    LAROS, GS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) : 1094 - 1107
  • [2] DENSITY OF FRESH AND EMBALMED HUMAN COMPACT AND CANCELLOUS BONE
    BLANTON, PL
    BIGGS, NL
    [J]. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1968, 29 (01) : 39 - &
  • [3] CHANG WS, 1987, CLIN ORTHOP RELAT R, V225, P141
  • [4] LONG-TERM RESULTS AND COMPLICATIONS OF CEMENT AUGMENTATION IN THE TREATMENT OF UNSTABLE TROCHANTERIC FRACTURES
    CHENG, CL
    CHOW, SP
    PUN, WK
    LEONG, JCY
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1989, 20 (03): : 134 - 138
  • [5] BIOMECHANICAL COMPARISON OF THE SLIDING HIP SCREW AND THE DOME PLUNGER
    CHOUEKA, J
    KOVAL, KJ
    KUMMER, FJ
    CRAWFORD, G
    ZUCKERMAN, JD
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (02): : 277 - 283
  • [6] FEMORAL-NECK FRACTURE FIXATION - COMPARISON OF A SLIDING SCREW WITH LAG SCREWS
    CLARK, DI
    CROFTS, CE
    SALEH, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (05): : 797 - 800
  • [7] Frankel V. H., 1960, FEMORAL NECK
  • [8] HARRINGTON KD, 1975, J BONE JOINT SURG AM, V57, P744
  • [9] LAROS GS, 1980, ORTHOP CLIN N AM, V11, P525
  • [10] EFFECT OF EMBALMING ON MECHANICAL PROPERTIES OF BEEF BONE
    MCELHANEY, J
    FOGLE, J
    BYARS, E
    WEAVER, G
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (06) : 1234 - &