Bi-enzymatic and capillary electrophoretic analysis of non-fluorescent compounds in microfluidic devices - Determination of xanthine

被引:55
作者
Richter, T
Shultz-Lockyear, LL
Oleschuk, RD
Bilitewski, U
Harrison, DJ
机构
[1] German Res Ctr Biotechnol GBFMBH, D-38124 Braunschweig, Germany
[2] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2002年 / 81卷 / 2-3期
关键词
xanthine; microfluidic devices; bi-enzyme system; chemiluminescence; indirect LIF detection;
D O I
10.1016/S0925-4005(01)00963-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report describes general investigations for xanthine determination in microfluidic devices. Xanthine is chosen as a model analyte for the detection of compounds via bi-enzymatic systems on one hand, and via capillary electrophoresis (CE) of non-fluorescent analytes on the other. The bi-enzyme system comprises xanthine oxidase (XOD) and horseradish peroxidase (HRP) with XOD giving the specificity for the analyte and HRP allowing chemiluminescent (CL) detection. Studies include the use of enzyme solutions, as well as enzyme coated beads pumped continuously through the device or trapped in a 330 pL cavity. In a second approach, indirect laser-induced fluorescence (LIF) is used as a detection method for microchip-based CE separations. Although the detection methods are not optimised, this report demonstrates general new possibilities for a fast determination of such compounds, in particular xanthine, in microfluidic devices. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:369 / 376
页数:8
相关论文
共 48 条
[1]  
Alarie JP, 2001, ELECTROPHORESIS, V22, P312, DOI 10.1002/1522-2683(200101)22:2<312::AID-ELPS312>3.0.CO
[2]  
2-3
[3]  
BARMAN TE, 1969, ENYZME HDB, V1
[4]   Protein sizing on a microchip [J].
Bousse, L ;
Mouradian, S ;
Minalla, A ;
Yee, H ;
Williams, K ;
Dubrow, R .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1207-1212
[5]   Development of a bienzymic graphite-Teflon composite electrode for the determination of hypoxanthine in fish [J].
Cayuela, G ;
Peña, N ;
Reviejo, AJ ;
Pingarrón, JM .
ANALYST, 1998, 123 (02) :371-377
[6]   Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay [J].
Cheng, SB ;
Skinner, CD ;
Taylor, J ;
Attiya, S ;
Lee, WE ;
Picelli, G ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1472-1479
[7]   UTILIZATION OF FLUORESCEIN SODIUM-SALT IN LASER-INDUCED INDIRECT FLUOROMETRIC DETECTION OF IONS SEPARATED BY CAPILLARY ZONE ELECTROPHORESIS [J].
DESBENE, PL ;
MORIN, CJ ;
MONVERNAY, AMD ;
GROULT, RS .
JOURNAL OF CHROMATOGRAPHY A, 1995, 689 (01) :135-148
[8]   Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays [J].
Dodge, A ;
Fluri, K ;
Verpoorte, E ;
de Rooij, NF .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3400-3409
[9]  
Dolník V, 2000, ELECTROPHORESIS, V21, P41, DOI 10.1002/(SICI)1522-2683(20000101)21:1<41::AID-ELPS41>3.0.CO
[10]  
2-7