Protein sizing on a microchip

被引:243
作者
Bousse, L [1 ]
Mouradian, S [1 ]
Minalla, A [1 ]
Yee, H [1 ]
Williams, K [1 ]
Dubrow, R [1 ]
机构
[1] Caliper Technol Corp, Mountain View, CA 94043 USA
关键词
D O I
10.1021/ac0012492
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
We have developed a microfabricated analytical device on a glass chip that performs a protein sizing assay, by integrating the required separation, staining, virtual destaining, and detection steps. To obtain a universal noncovalent fluorescent labeling method, we have combined on-chip dye staining with a novel electrophoretic dilution step. Denatured protein-sodium dodecyl sulfate (SDS) complexes are loaded on a chip and bind a fluorescent dye as the separation begins. At the end of the separation channel, an intersection is used to dilute the SDS below its critical micelle concentration before the detection point. This strongly reduces the background due to dye molecules bound to SDS micelles and also increases the peak amplitude by 1 order of magnitude. Both the on-chip staining and SDS dilution steps occur in the 100-ms time scale and are similar to 10(4) times faster than their conventional counterparts in SDS-PAGE, This represents a much greater speed increase due to microfabrication than has been obtained in other assay steps such as electrophoretic separations. We have designed and tested a microchip capable of sequentially analyzing ii different samples, with sizing accuracy better than 5% and high sensitivity (30 nM for carbonic anhydrase).
引用
收藏
页码:1207 / 1212
页数:6
相关论文
共 41 条
[1]
Electrokinetically controlled microfluidic analysis systems [J].
Bousse, L ;
Cohen, C ;
Nikiforov, T ;
Chow, A ;
Kopf-Sill, AR ;
Dubrow, R ;
Parce, JW .
ANNUAL REVIEW OF BIOPHYSICS AND BIOMOLECULAR STRUCTURE, 2000, 29 :155-181
[2]
Bousse L., 1998, MICRO TOTAL ANAL SYS, V98, P271
[3]
DETERMINATION OF THE CRITICAL MICELLE CONCENTRATION OF SURFACTANTS USING THE FLUORESCENT-PROBE N-PHENYL-1-NAPHTHYLAMINE [J].
BRITO, RMM ;
VAZ, WLC .
ANALYTICAL BIOCHEMISTRY, 1986, 152 (02) :250-255
[4]
An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[5]
FLUORIMETRIC DETERMINATION OF CRITICAL MICELLE CONCENTRATION AVOIDING INTERFERENCE FROM DETERGENT CHARGE [J].
CHATTOPADHYAY, A ;
LONDON, E .
ANALYTICAL BIOCHEMISTRY, 1984, 139 (02) :408-412
[6]
Chiem NH, 1998, CLIN CHEM, V44, P591
[7]
Chien R. L., 1992, ANAL CHEM, V64, P489
[8]
ELECTROOSMOTIC PROPERTIES AND PEAK BROADENING IN FIELD-AMPLIFIED CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
HELMER, JC .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1354-1361
[9]
Chow A, 2000, MESA MG, P489
[10]
HIGH-PERFORMANCE SODIUM DODECYL-SULFATE POLYACRYLAMIDE-GEL CAPILLARY ELECTROPHORESIS OF PEPTIDES AND PROTEINS [J].
COHEN, AS ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1987, 397 :409-417