Breath-by-breath assessment of alveolar gas stores and exchange

被引:25
作者
Aliverti, A
Kayser, B
Macklem, PT
机构
[1] Politecn Milan, Dipartimento Bioingn, Lab Tecnol Biomed, I-20133 Milan, Italy
[2] Univ Geneva, Fac Med, CH-1205 Geneva, Switzerland
[3] McGill Univ, Ctr Hlth, Montreal Chest Inst, Meakins Christie Labs, Montreal, PQ H2X 2P4, Canada
关键词
oxygen consumption; exercise; opto-electronic plethysmography; respiration;
D O I
10.1152/japplphysiol.01198.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The volume of O-2 exchanged at the mouth during a breath (VO2,m) is equal to that taken up by pulmonary capillaries (V-O2,V-A) only if lung O-2 stores are constant. The latter change if either end-expiratory lung volume (EELV), or alveolar O-2 fraction (F-AO2) change. Measuring this requires breath-by-breath (BbB) measurement of absolute EELV, for which we used optoelectronic plethysmography combined with measurement of O-2 fraction at the mouth to measure V-O2,V-A = V-O2,V-m - (DeltaEELV.F-AO2 + EELV.DeltaF(AO2)), and divided by respiratory cycle time to obtain BbB O-2 consumption ((V)overdot O-2) in seven healthy men during incremental exercise and recovery. To synchronize O-2 and volume signals, we measured gas transit time from mouthpiece to O-2 meter and compared (V)over dotO(2) measured during steady-state exercise by using expired gas collection with the mean BbB measurement over the same time period. In one subject, we adjusted the instrumental response time by 20-ms increments to maximize the agreement between the two (V)over dot O-2 measurements. We then applied the same total time delay (transit time plus instrumental delay = 660 ms) to all other subjects. The comparison of pooled data from all subjects revealed r(2) = 0.990, percent error = 0.039 +/- 1.61 SE, and slope = 1.02 +/- 0.015 ( SE). During recovery, increases in EELV introduced systematic errors in (V)over dot O-2 if measured without taking DeltaEELV.F-AO2 + EELV.DeltaF(AO2) into account. We conclude that optoelectronic plethysmography can be used to measure BbB (V)over dot O-2 accurately when studying BbB gas exchange in conditions when EELV changes, as during on- and off-transients.
引用
收藏
页码:1464 / 1469
页数:6
相关论文
共 11 条
[1]   CONTRIBUTION OF PULMONARY STORES TO OXYGEN UPTAKE [J].
AUCHINCLOSS, JH ;
GILBERT, R ;
BAULE, GH .
JOURNAL OF APPLIED PHYSIOLOGY, 1970, 29 (02) :230-+
[2]   EFFECT OF VENTILATION ON OXYGEN TRANSFER DURING EARLY EXERCISE [J].
AUCHINCLOSS, JH ;
GILBERT, R ;
BAULE, GH .
JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (03) :810-+
[3]   Chest wall and lung volume estimation by optical reflectance motion analysis [J].
Cala, SJ ;
Kenyon, CM ;
Ferrigno, G ;
Carnevali, P ;
Aliverti, A ;
Pedotti, A ;
Macklem, PT ;
Rochester, DF .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (06) :2680-2689
[4]   New perspectives in breath-by-breath determination of alveolar gas exchange in humans [J].
Capelli, C ;
Cautero, M ;
di Prampero, PE .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2001, 441 (04) :566-577
[5]   Breath-by-breath alveolar oxygen transfer at the onset of step exercise in humans: methodological implications [J].
Cautero, M ;
Beltrami, AP ;
di Prampero, PE ;
Capelli, C .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 88 (03) :203-213
[6]   Estimation of end-expiratory lung volume variations by optoelectronic plethysmography [J].
Dellacà, RL ;
Aliverti, A ;
Pelosi, P ;
Carlesso, E ;
Chiumello, D ;
Pedotti, A ;
Gattinoni, L .
CRITICAL CARE MEDICINE, 2001, 29 (09) :1807-1811
[7]   BREATH-BY-BREATH ESTIMATE OF ALVEOLAR GAS TRANSFER VARIABILITY IN MAN AT REST AND DURING EXERCISE [J].
DIPRAMPERO, PE ;
LAFORTUNA, CL .
JOURNAL OF PHYSIOLOGY-LONDON, 1989, 415 :459-475
[8]   A NEW METHOD FOR BREATH-TO-BREATH DETERMINATION OF OXYGEN FLUX ACROSS THE ALVEOLAR MEMBRANE [J].
GRONLUND, J .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1984, 52 (02) :167-172
[9]   Determinants of exercise performance in normal men with externally imposed expiratory flow limitation [J].
Iandelli, I ;
Aliverti, A ;
Kayser, B ;
Dellacà, R ;
Cala, SJ ;
Duranti, R ;
Kelly, S ;
Scano, G ;
Sliwinski, P ;
Yan, S ;
Macklem, PT ;
Pedotti, A .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 92 (05) :1943-1952
[10]  
LINNARSSON D, 1974, ACTA PHYSIOL SCAND, P1