Efficiency and temperature dependence of water removal by membrane dryers

被引:62
作者
Leckrone, KJ
Hayes, JM
机构
[1] INDIANA UNIV,DEPT CHEM,BIOGEOCHEM LABS,BLOOMINGTON,IN 47405
[2] INDIANA UNIV,DEPT CHEM,DEPT GEOL SCI,BLOOMINGTON,IN 47405
关键词
D O I
10.1021/ac9610220
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The vapor pressure of water in equilibrium with sorption sites within a Nafion membrane is given by log P-WN =-3580/T + 10.01, where P-WN is expressed in Torr and T is the membrane temperature, in kelvin. The efficiency of dryers based on selective permeation of water through Nation can thus be enhanced by cooling the membrane. Residual water in effluents exceeds equilibrium levels if insufficient time is allowed for water to diffuse to the membrane surface as gas passes through the dryer. For tubular configurations, this limitation can be avoided if L greater than or equal to F-c(10(3.8)/120 pi D), where L is the length of the tubular membrane, in centimeters, F-c is the gas flow rate, in mL/min, and D is the diffusion coefficient for water in the carrier gas at the operating temperature of the dryer, in cm(2)/. An efficient dryer that at room temperature dries gas to a dew point of -61 degrees C is described; the same dryer maintained at 0 degrees C yields a dew point of -80 degrees C and removes water as effectively as Mg(ClO4)(2) or a dry ice/acetone slush. The use of Nafion membranes to construct devices capable of delivering gas streams with low but precisely controlled humidities is discussed.
引用
收藏
页码:911 / 918
页数:8
相关论文
共 41 条
[1]  
ATKINS PW, 1986, PHYSICAL CHEM
[2]   MEASURING TRACE IMPURITIES IN AIR BY INFRARED SPECTROSCOPY AT 20 METERS PATH AND 10 ATMOSPHERES PRESSURE [J].
BAKER, BB .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1974, 35 (11) :735-740
[3]   EMPIRICAL-METHODS FOR DETERMINATION OF IONIZATION GAUGE RELATIVE SENSITIVITIES FOR DIFFERENT GASES [J].
BARTMESS, JE ;
GEORGIADIS, RM .
VACUUM, 1983, 33 (03) :149-153
[4]   PROBLEMS WITH A NAFION MEMBRANE DRYER FOR DRYING CHROMATOGRAPHIC SAMPLES [J].
BURNS, WF ;
TINGEY, DT ;
EVANS, RC ;
BATES, EH .
JOURNAL OF CHROMATOGRAPHY, 1983, 269 (01) :1-9
[5]   EFFECT OF WATER AND CARBON-DIOXIDE IN CHEMI-LUMINESCENT MEASUREMENT OF OXIDES OF NITROGEN [J].
CAMPBELL, NT ;
BERES, GA ;
BLASKO, TJ ;
GROTH, RH .
JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1982, 32 (05) :533-535
[6]   ANALYSIS OF VOLATILE ORGANIC-CHEMICALS IN AQUEOUS SAMPLES BY PURGE GC WITH SELECTIVE WATER REMOVAL [J].
COCHRAN, JW ;
HENSON, JM .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (12) :869-873
[7]   EFFECTS OF MOISTURE ON THE COLD VAPOR DETERMINATION OF MERCURY AND ITS REMOVAL BY USE OF MEMBRANE DRYER TUBES [J].
CORNS, WT ;
EBDON, L ;
HILL, SJ ;
STOCKWELL, PB .
ANALYST, 1992, 117 (04) :717-719
[8]   DETERMINATION OF TRACE LEVEL ORGANICS IN AMBIENT AIR BY HIGH-RESOLUTION GAS-CHROMATOGRAPHY WITH SIMULTANEOUS PHOTO-IONIZATION AND FLAME IONIZATION DETECTION [J].
COX, RD ;
EARP, RF .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2265-2270
[9]  
Cussler E. L., 1984, DIFFUSION MASS TRANS
[10]   SOME INSTRUMENTAL EFFECTS IN THE DETERMINATION OF STABLE CARBON ISOTOPE RATIOS BY GAS-CHROMATOGRAPHY ISOTOPE RATIO MASS-SPECTROMETRY [J].
EAKIN, PA ;
FALLICK, AE ;
GERC, J .
CHEMICAL GEOLOGY, 1992, 101 (1-2) :71-79