Detection of meningitis antigens in buffer and body fluids by ultrasound-enhanced particle agglutination

被引:27
作者
Jenkins, P
Barnes, RA
Coakley, WT
机构
[1] UNIV WALES COLL CARDIFF,SCH PURE & APPL BIOL,CARDIFF CF1 3TL,S GLAM,WALES
[2] UNIV WALES COLL MED,DEPT MED MICROBIOL,CARDIFF CF4 4XN,S GLAM,WALES
关键词
latex agglutination test; ultrasonic standing wave; meningitis diagnosis; antigen detection; immunoassay; ultrasonic enhancement of immunoassay; Streptococcus group B; Haemophilus influenzae type b; Neisseria meningitis ACY W135; Neisseria meningitis; Streptococcus pneumoniae;
D O I
10.1016/S0022-1759(97)00076-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The standard test card agglutination of antibody-coated latex by Neisseria meningitidis, Streptococcus group B, Haemophilus influenzae type b and Streptococcus pneumoniae antigens has been compared with a technique involving local concentration of the coated latex in an ultrasonic standing wave. The detection of positive control antigen was enhanced, compared with the test-card procedure, over a 16 to 64 fold range on exposure to ultrasound. Sample filtration eliminated non-specific agglutination on ultrasonic exposure of latex in control serum, urine or concentrated urine. Tests of meningitis patient body fluids showed increased detection of antigen with ultrasound for CSF (11/14 > 7/14) serum (8/13 > 3/13) and concentrated urine (8/17 > 2/17) compared to test card assays. The ultrasound detection of antigen in serum or concentrated urine was comparable to that achieved with CSF on test cards. Serum dilution experiments showed that ultrasound could detect antigen in serum over a 1000 fold concentration range. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:191 / 200
页数:10
相关论文
共 20 条
[1]  
BANGS L, 1996, DIAGNOSTIC APPL LATE, pCH6
[2]   THE ROLE OF BACTERIAL-ANTIGEN DETECTION TESTS IN THE DIAGNOSIS OF BACTERIAL-MENINGITIS [J].
BHISITKUL, DM ;
HOGAN, AE ;
TANZ, RR .
PEDIATRIC EMERGENCY CARE, 1994, 10 (02) :67-71
[3]   EVALUATION OF A NEW TUBE LATEX AGGLUTINATION-TEST FOR DETECTION OF TYPE-SPECIFIC PNEUMOCOCCAL ANTIGENS IN URINE [J].
CAPEDING, MRZ ;
NOHYNEK, H ;
RUUTU, P ;
LEINONEN, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (09) :1818-1821
[4]  
Coakley W. Terence, 1994, Bioseparation, V4, P73
[5]  
DENIS F, 1986, REV FR LAB, V148, P51
[6]  
FUNG JC, 1985, MANUAL CLIN MICROBIO, P883
[7]  
GRUNDY MA, 1989, J CLIN LAB IMMUNOL, V30, P93
[8]  
GRUNDY MA, 1995, J MED VET MYCOL, V33, P201
[9]   RAPID AGGLUTINATION TESTING IN AN ULTRASONIC STANDING-WAVE [J].
GRUNDY, MA ;
BOLEK, WE ;
COAKLEY, WT ;
BENES, E .
JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 165 (01) :47-57
[10]   INCREASED SENSITIVITY OF DIAGNOSTIC LATEX AGGLUTINATION TESTS IN AN ULTRASONIC STANDING-WAVE FIELD [J].
GRUNDY, MA ;
MOORE, K ;
COAKLEY, WT .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 176 (02) :169-177