Comparative effects of permanent biventricular pacing for refractory heart failure in patients with stable sinus rhythm or chronic atrial fibrillation

被引:109
作者
Leclercq, C
Victor, F
Alonso, C
Pavin, D
d'Allones, GR
Bansard, JY
Mabo, P
Daubert, C
机构
[1] Univ Hosp, Dept Cardiol & Malad Vasc, Rennes, France
[2] Univ Hosp, Dept Sante Publ, Rennes, France
关键词
D O I
10.1016/S0002-9149(00)00716-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to compare the long-term benefit of biventricular pacing in drug-refractory heart failure in patients with dilated cardiomyopathy who were in stable sinus rhythm or had persistent atrial fibrillation, The results showed that permanent biventricular pacing in such patients significantly improves exercise tolerance in both groups of patients; however, the benefit tended to be greater in patients with atrial fibrillation.
引用
收藏
页码:1154 / +
页数:4
相关论文
共 13 条
[1]  
Blanc JJ, 1997, CIRCULATION, V96, P3273
[2]   Multisite pacing for end-stage heart failure: Early experience [J].
Cazeau, S ;
Ritter, P ;
Lazarus, A ;
Gras, D ;
Backdach, H ;
Mundler, O ;
Mugica, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11) :1748-1757
[3]  
EDNER M, 1995, BRIT HEART J, V74, P261
[4]   Evaluation of left ventricular based pacing in patients with congestive heart failure and atrial fibrillation [J].
Etienne, Y ;
Mansourati, J ;
Gilard, M ;
Valls-Bertault, V ;
Boschat, J ;
Benditt, DG ;
Lurie, KG ;
Blanc, JJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (07) :1138-+
[5]   Multisite pacing as a supplemental treatment of congestive heart failure: Preliminary results of the Medtronic Inc. InSync study [J].
Gras, D ;
Mabo, P ;
Tang, T ;
Luttikuis, O ;
Chatoor, R ;
Pedersen, AK ;
Tscheliessnigg, HH ;
Deharo, JC ;
Puglisi, A ;
Silvestre, J ;
Kimber, S ;
Ross, H ;
Ravazzi, A ;
Paul, V ;
Skehan, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2249-2255
[6]   IMPROVEMENT IN LEFT-VENTRICULAR SYSTOLIC FUNCTION AFTER SUCCESSFUL RADIOFREQUENCY HIS-BUNDLE ABLATION FOR DRUG REFRACTORY, CHRONIC ATRIAL-FIBRILLATION AND RECURRENT ATRIAL-FLUTTER [J].
HEINZ, G ;
SIOSTRZONEK, P ;
KREINER, G ;
GOSSINGER, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (05) :489-492
[7]   USEFULNESS OF PHYSIOLOGICAL DUAL-CHAMBER PACING IN DRUG-RESISTANT IDIOPATHIC DILATED CARDIOMYOPATHY [J].
HOCHLEITNER, M ;
HORTNAGL, H ;
NG, CK ;
HORTNAGL, H ;
GSCHNITZER, F ;
ZECHMANN, W .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (02) :198-202
[8]   Improved left ventricular mechanics from acute VDD pacing in patients with dilated cardiomyopathy and ventricular conduction delay [J].
Kass, DA ;
Chen, CH ;
Curry, C ;
Talbot, M ;
Berger, R ;
Fetics, B ;
Nevo, E .
CIRCULATION, 1999, 99 (12) :1567-1573
[9]   Acute hemodynamic effects of biventricular DDD pacing in patients with end-stage heart failure [J].
Leclercq, C ;
Cazeau, S ;
Le Breton, H ;
Ritter, P ;
Mabo, P ;
Gras, D ;
Pavin, D ;
Lazarus, A ;
Daubert, JC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1825-1831
[10]   MECHANISM OF HEMODYNAMIC IMPROVEMENT BY DUAL-CHAMBER PACING FOR SEVERE LEFT-VENTRICULAR DYSFUNCTION - AN ACUTE DOPPLER AND CATHETERIZATION HEMODYNAMIC-STUDY [J].
NISHIMURA, RA ;
HAYES, DL ;
HOLMES, DR ;
TAJIK, AJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (02) :281-288