Multisite pacing as a supplemental treatment of congestive heart failure: Preliminary results of the Medtronic Inc. InSync study

被引:277
作者
Gras, D [1 ]
Mabo, P [1 ]
Tang, T [1 ]
Luttikuis, O [1 ]
Chatoor, R [1 ]
Pedersen, AK [1 ]
Tscheliessnigg, HH [1 ]
Deharo, JC [1 ]
Puglisi, A [1 ]
Silvestre, J [1 ]
Kimber, S [1 ]
Ross, H [1 ]
Ravazzi, A [1 ]
Paul, V [1 ]
Skehan, D [1 ]
机构
[1] Ctr Chirurg Val dOr, F-92211 St Cloud, France
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1998年 / 21卷 / 11期
关键词
pacing; heart failure; multisite pacing; left ventricular pacing;
D O I
10.1111/j.1540-8159.1998.tb01162.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This report describes the initial results of the "lnSync" study, a European and Canadian multicenter trial that examines the safety and efficacy of a multisite pacemaker (Medtronic InSync) and of left ventricular pacing leads (Medtronic 2187 and 2288) implanted via a cardiac vein as a supplemental treatment of refractory congestive heart failure. Over a 10-month period, the system was implanted successfully in 68 of the 81 (84%) patients who had been enrolled in the study. The 68 patients were, on average, 66 +/- 10 years old, had a mean left ventricular ejection fraction (LVEF) = 21% +/- 9%, and 63% were in NYHA functional Class III and 37% were in Class IV. No system implant related complication occurred. During follow-up, 7 of 10 patients who exited the study had died, 4 suddenly. There was a clinical benefit among surviving patients, which was corroborated by a significant improvement in NYHA functional class and in the Minnesota Living with Heart Failure Quality of Life Questionnaire Score (MLS) and by a longer distance covered during a 6-minute walk test. This clinical improvement was associated with a significant narrowing of the paced QRS complex during biventricular pacing, a significant decrease in the interventricular mechanical delay, and a trend towards an increase in the duration of ventricular filling. These encouraging preliminary results confirm the feasibility and reliability of this new multisite pacing system in the management of dilated cardiomyopathy and support the continuation of further evaluations of this complementary treatment of refractory congestive heart failure.
引用
收藏
页码:2249 / 2255
页数:7
相关论文
共 18 条
  • [1] Permanent multisite cardiac pacing
    Barold, SS
    Cazeau, S
    Mugica, J
    Garrigue, S
    Clementy, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (11): : 2725 - 2729
  • [2] Multisite pacing for end-stage heart failure: Early experience
    Cazeau, S
    Ritter, P
    Lazarus, A
    Gras, D
    Backdach, H
    Mundler, O
    Mugica, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11): : 1748 - 1757
  • [3] Permanent left atrial pacing with a specifically designed coronary sinus lead
    Daubert, C
    Leclercq, C
    LeBreton, H
    Gras, D
    Pavin, D
    Pouvreau, Y
    VanVerooij, P
    Bakels, N
    Mabo, P
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (11): : 2755 - 2764
  • [4] Permanent left ventricular pacing with transvenous leads inserted into the coronary veins
    Daubert, JC
    Ritter, P
    Le Breton, H
    Gras, D
    LeClercq, C
    Lazarus, A
    Mugica, J
    Mabo, P
    Cazeau, S
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01): : 239 - 245
  • [5] DUAL-CHAMBER PACING WITH A SHORT ATRIOVENTRICULAR DELAY IN CONGESTIVE-HEART-FAILURE - A RANDOMIZED STUDY
    GOLD, MR
    FELICIANO, Z
    GOTTLIEB, SS
    FISHER, ML
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (04) : 967 - 973
  • [6] Multisite pacing as a supplemental treatment of congestive heart failure: Preliminary results of the Medtronic Inc. InSync study
    Gras, D
    Mabo, P
    Tang, T
    Luttikuis, O
    Chatoor, R
    Pedersen, AK
    Tscheliessnigg, HH
    Deharo, JC
    Puglisi, A
    Silvestre, J
    Kimber, S
    Ross, H
    Ravazzi, A
    Paul, V
    Skehan, D
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11): : 2249 - 2255
  • [7] Gras D, 1997, PACEMAKER LEADS 1997, P239
  • [8] FUNCTIONAL ABNORMALITIES IN ISOLATED LEFT-BUNDLE BRANCH-BLOCK - THE EFFECT OF INTERVENTRICULAR ASYNCHRONY
    GRINES, CL
    BASHORE, TM
    BOUDOULAS, H
    OLSON, S
    SHAFER, P
    WOOLEY, CF
    [J]. CIRCULATION, 1989, 79 (04) : 845 - 853
  • [9] LONG-TERM EFFICACY OF PHYSIOLOGICAL DUAL-CHAMBER PACING IN THE TREATMENT OF END-STAGE IDIOPATHIC DILATED CARDIOMYOPATHY
    HOCHLEITNER, M
    HORTNAGL, H
    HORTNAGL, H
    FRIDRICH, L
    GSCHNITZER, F
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (15) : 1320 - 1325
  • [10] HEMODYNAMIC IMPORTANCE OF PRESERVING THE NORMAL SEQUENCE OF VENTRICULAR ACTIVATION IN PERMANENT CARDIAC PACING
    LECLERCQ, C
    GRAS, D
    LEHELLOCO, A
    NICOL, L
    MABO, P
    DAUBERT, C
    [J]. AMERICAN HEART JOURNAL, 1995, 129 (06) : 1133 - 1141