Construction and characterization of the direct piezoelectric immunosensor for atrazine operating in solution

被引:84
作者
Steegborn, C
Skladal, P
机构
[1] MASARYK UNIV,DEPT BIOCHEM,CS-61137 BRNO,CZECH REPUBLIC
[2] UNIV BAYREUTH,BIOCHEM LAB,D-95440 BAYREUTH,GERMANY
关键词
immunosensor; piezoelectric biosensor; quartz crystal microbalance; monoclonal antibody; atrazine; competitive assay; kinetic constants;
D O I
10.1016/0956-5663(96)89086-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The direct immunosensor for determination of the herbicide atrazine was studied. The gold electrodes of the piezoelectric quartz crystal were silanized and activated using glutaraldehyde. The bioaffinity ligand atrazine was linked through albumin as a spacer molecule. The modified piezoelectric crystal was placed in a flow cell and all measurements were performed directly in flowing solution. The interaction of the anti atrazine monoclonal antibody (MAb, clone D6F3) with the immobilized atrazine was characterized using both crude ascitic fluid and Protein A-purified MAI, preparates. The association and dissociation rate constants were determined, k(a) = 1.21 x 10(5) M(-1) s(-1) and k(d) = 4.0 x 10(-4) s(-1). The competitive determination of free atrazine was studied using different dilutions (100X, 250X and 1000X) of the ascitic fluid containing MAb. MAb was preincubated with atrazine (concentrations 0.1 mu g/l) for 15 min and the mixture was then introduced to the flow cell. As a signal, either the rate of frequency decrease or the relative change of frequency after the fixed binding period (10 min) was evaluated. As expected, the higher dilutions of MAb provided improved sensitivity for the analyte. For the 1000X diluted ascitic fluid, 0.1 and 1 mu g/l atrazine caused 5 and 30% decreases of the relative binding of MAb, respectively. Repeated use of the crystals was achieved using a 5 min flow of 100 mM NaOH for regeneration. The results obtained seem to be promising for determination of atrazine in drinking water using direct piezoelectric immunosensors. (C) 1996 Elsevier Science Limited
引用
收藏
页码:19 / 27
页数:9
相关论文
共 33 条
[1]   A BIOSENSOR AS WARNING DEVICE FOR THE DETECTION OF CYANIDE, CHLOROPHENOLS, ATRAZINE AND CARBAMATE PESTICIDES [J].
BESOMBES, JL ;
COSNIER, S ;
LABBE, P ;
REVERDY, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :255-263
[2]   REAL-TIME ANALYSIS OF COMPETITIVE-BINDING USING GRATING COUPLER IMMUNOSENSORS FOR PESTICIDE DETECTION [J].
BIER, FF ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (02) :125-130
[3]   A DIRECT OPTICAL IMMUNOSENSOR FOR ATRAZINE DETECTION [J].
BRECHT, A ;
PIEHLER, J ;
LANG, G ;
GAUGLITZ, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :289-299
[4]   RAPID IMMUNOFILTRATION ASSAY FOR THE DETERMINATION OF ATRAZINE IN WATER AND SOIL SAMPLES [J].
DANKWARDT, A ;
HOCK, B .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) :R20-R21
[5]   DIRECT POTENTIOMETRIC IMMUNOELECTRODES .3. A GRAPHITE BASED ATRAZINE IMMUNOELECTRODE [J].
ENGEL, L ;
BAUMANN, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9) :745-751
[6]   MEASUREMENT OF KINETIC BINDING CONSTANTS OF A PANEL OF ANTI-SAPORIN ANTIBODIES USING A RESONANT MIRROR BIOSENSOR [J].
GEORGE, AJT ;
FRENCH, RR ;
GLENNIE, MJ .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 183 (01) :51-63
[7]   A NEW MONOCLONAL-ANTIBODY FOR THE SENSITIVE DETECTION OF ATRAZINE WITH IMMUNOASSAY IN MICROTITER PLATE AND DIPSTICK FORMAT [J].
GIERSCH, T .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1993, 41 (06) :1006-1011
[8]   A PIEZOELECTRIC IMMUNOBIOSENSOR FOR ATRAZINE IN DRINKING-WATER [J].
GUILBAULT, GG ;
HOCK, B ;
SCHMID, R .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (06) :411-419
[9]   CAPILLARY ENZYME-IMMUNOASSAY WITH ELECTROCHEMICAL DETECTION FOR THE DETERMINATION OF ATRAZINE IN WATER [J].
JIANG, TB ;
HALSALL, HB ;
HEINEMAN, WR ;
GIERSCH, T ;
HOCK, B .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (04) :1098-1104
[10]   ENHANCEMENT OF IMMUNOASSAY SENSITIVITY BY MOLECULAR MODIFICATION OF COMPETITORS [J].
JOCKERS, R ;
BIER, FF ;
SCHMID, RD .
JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 163 (02) :161-167