REAL-TIME ANALYSIS OF COMPETITIVE-BINDING USING GRATING COUPLER IMMUNOSENSORS FOR PESTICIDE DETECTION

被引:77
作者
BIER, FF
SCHMID, RD
机构
[1] GBF-Gesellschaft für Biotechnologische Forschung mbH, Department of Enzyme Technology, Project Group Biosensors, D-38124 Braunschweig
关键词
INTEGRATED OPTICS; GRATING COUPLER; IMMUNOSENSOR; REAL TIME ANALYSIS; ANTIBODY BINDING KINETICS; PESTICIDES;
D O I
10.1016/0956-5663(94)80103-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Real time analysis of binding events is one step forward from immunoassays to immunosensors. Using grating couplers as transducers, the approach is adapted to hapten detection by a competitive assay format. A special advantage of real time analysis is the information obtained from the kinetic behaviour of the immunosystem. In this study we show that the interpretation of the dynamic system response compared to a quasi-stationary one shifts the detection limit to lower hapten concentrations, and shortens the assay time. In the case of s-triazines, it was found that the detection limit decreases by 4 times, while incubation time is shortened tenfold to 3 min.
引用
收藏
页码:125 / 130
页数:6
相关论文
共 17 条
[1]   USE OF A FIBER OPTIC IMMUNOSENSOR FOR THE DETECTION OF PESTICIDES [J].
BIER, FF ;
STOCKLEIN, W ;
BOCHER, M ;
BILITEWSKI, U ;
SCHMID, RD .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :509-512
[2]  
BIER FF, 1992, GBF MONOG SERIES, V17, P205
[3]  
BIER FF, 1993, IN PRESS ANALYST LON
[4]   DEXTRAN, A HAPTEN CARRIER IN IMMUNOASSAYS FOR S-TRIAZINES - A COMPARISON WITH ELISAS BASED ON HAPTEN-PROTEIN CONJUGATES [J].
BOCHER, M ;
GIERSCH, T ;
SCHMID, RD .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 151 (1-2) :1-8
[5]  
EDDOWES MJ, 1987, BIOSENSORS, V3, P1
[6]  
GIERSCH T, 1990, Food and Agricultural Immunology, V2, P85, DOI 10.1080/09540109009354707
[7]   ENZYME IMMUNOASSAYS FOR THE DETERMINATION OF S-TRIAZINES IN WATER SAMPLES - 2 INTERLABORATORY TESTS [J].
HOCK, B .
ANALYTICAL LETTERS, 1991, 24 (04) :529-549
[8]   KINETIC-ANALYSIS OF MONOCLONAL ANTIBODY-ANTIGEN INTERACTIONS WITH A NEW BIOSENSOR BASED ANALYTICAL SYSTEM [J].
KARLSSON, R ;
MICHAELSSON, A ;
MATTSSON, L .
JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 145 (1-2) :229-240
[9]   FLOW-INJECTION IMMUNOANALYSIS (FIIA) - A NEW IMMUNOASSAY FORMAT FOR THE DETERMINATION OF PESTICIDES IN WATER [J].
KRAMER, P ;
SCHMID, R .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (03) :239-243
[10]   SENSITIVITY OF INTEGRATED OPTICAL GRATING AND PRISM COUPLERS AS (BIO)CHEMICAL SENSORS [J].
LUKOSZ, W ;
TIEFENTHALER, K .
SENSORS AND ACTUATORS, 1988, 15 (03) :273-284