Automated generation of curved planar reformations from volume data: Method and evaluation

被引:37
作者
Raman, R [1 ]
Napel, S [1 ]
Beaulieu, CF [1 ]
Bain, ES [1 ]
Jeffrey, RB [1 ]
Rubin, GD [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
关键词
angiography; technology; arteries; CT; computed tomography (CT); helical; images; processing; veins;
D O I
10.1148/radiol.2231010441
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors developed and evaluated a method to automatically create interactive vascular curved planar reformations with computed tomographic (CT) angiographic data. The method decreased user interaction time by 86%, from 15 to 2 minutes. Expert reviewers were asked to indicate their confidence in differentiating automatically created images from clinical-quality manually produced images. The area under the receiver operating characteristic curve was 0.45 (95% Cl: 0.39, 0.51), and a test of equivalency indicated that reviewers could not distinguish between images. They also graded image quality as equivalent to that with manual methods and found fewer artifacts on automatically created images. Automatic methods rapidly produce curved planar reformations of equivalent quality with reduced time and effort. © RSNA, 2002.
引用
收藏
页码:275 / 280
页数:6
相关论文
共 14 条
[1]   Curved multiplanar reconstructions for the evaluation of contrast-enhanced electron beam CT of the coronary arteries [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Bachmann, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (04) :895-899
[2]   Helical CT of the urinary tract [J].
Fielding, JR ;
Silverman, SG ;
Rubin, GD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) :1199-1206
[3]   Increasing spiral CT benefits with postprocessing applications [J].
Kirchgeorg, MA ;
Prokop, M .
EUROPEAN JOURNAL OF RADIOLOGY, 1998, 28 (01) :39-54
[4]  
Ochi T, 1999, AM J NEURORADIOL, V20, P1025
[5]   Automated flight path planning for virtual endoscopy [J].
Paik, DS ;
Beaulieu, CF ;
Jeffrey, RB ;
Rubin, GD ;
Napel, S .
MEDICAL PHYSICS, 1998, 25 (05) :629-637
[6]   Spiral CT: vascular applications [J].
Rankin, SC .
EUROPEAN JOURNAL OF RADIOLOGY, 1998, 28 (01) :18-29
[7]   Are Greek letter social organizations a factor in undergraduates' perceptions of international instructors? [J].
Rubin, DL ;
Ainsworth, S ;
Cho, E ;
Turk, D ;
Winn, L .
INTERNATIONAL JOURNAL OF INTERCULTURAL RELATIONS, 1999, 23 (01) :1-12
[8]   3-DIMENSIONAL HELICAL CT ANGIOGRAPHY [J].
RUBIN, GD .
RADIOGRAPHICS, 1994, 14 (04) :905-912
[9]  
RUBIN GD, 1995, RADIOL CLIN N AM, V33, P903
[10]   Spiral (helical) CT of the renal vasculature [J].
Rubin, GD .
SEMINARS IN ULTRASOUND CT AND MRI, 1996, 17 (04) :374-397