Spiral CT: vascular applications

被引:29
作者
Rankin, SC [1 ]
机构
[1] Guys Hosp, Dept Radiol, London SE1 9RT, England
关键词
CT angiography; carotid artery; aorta; renal artery;
D O I
10.1016/S0720-048X(98)00009-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent technical advances in CT have renewed interest in the development of CT angiography (CTA). CT angiography is a minimally invasive method of visualising the vascular system and is becoming an alternative to conventional arteriography in some situations. Spiral technology allows a volume of data to be obtained on a single breath-hold with no respiratory misregistration. Fast machines with second or subsecond acquisition times mean the images are obtained while there are high circulating levels of contrast medium giving peak vascular opacification from a peripheral intravenous injection. Accurate timing will ensure either the arterial or venous phase is imaged. Multiple overlapping axial-images can be obtained from the data set with no increase in radiation dose to the patient and from these scans computer generated multiplanar and 3D images are obtained which can be viewed from numerous angles. CT angiography can be performed more quickly, less invasively and at reduced cost compared to conventional angiography. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:18 / 29
页数:12
相关论文
共 55 条
  • [1] SPIRAL CT-ANGIOGRAPHY OF THE AORTA
    BALM, R
    EIKELBOOM, BC
    VANLEEUWEN, MS
    NOORDZIJ, J
    [J]. EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (05): : 544 - 551
  • [2] Helical CT angiography compared with arteriography in the detection of renal artery stenosis
    Beregi, JP
    Elkohen, M
    Deklunder, G
    Artaud, D
    Coullet, JM
    Wattinne, L
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) : 495 - 501
  • [3] BRINK JA, 1995, RADIOL CLIN N AM, V33, P825
  • [4] SPIRAL CT - DECREASED SPATIAL-RESOLUTION INVIVO DUE TO BROADENING OF SECTION-SENSITIVITY PROFILE
    BRINK, JA
    HEIKEN, JP
    BALFE, DM
    SAGEL, SS
    DICROCE, J
    VANNIER, MW
    [J]. RADIOLOGY, 1992, 185 (02) : 469 - 474
  • [5] TECHNICAL OPTIMIZATION OF SPIRAL CT FOR DEPICTION OF RENAL-ARTERY STENOSIS - IN-VITRO ANALYSIS
    BRINK, JA
    LIM, JT
    WANG, G
    HEIKEN, JP
    DEYOE, LA
    VANNIER, MW
    [J]. RADIOLOGY, 1995, 194 (01) : 157 - 163
  • [6] HELICAL CT - PRINCIPLES AND TECHNICAL CONSIDERATIONS
    BRINK, JA
    HEIKEN, JP
    WANG, G
    MCENERY, KW
    SCHLUETER, FJ
    VANNIER, MW
    [J]. RADIOGRAPHICS, 1994, 14 (04) : 887 - 893
  • [7] CAROTID SONOGRAPHY
    CARROLL, BA
    [J]. RADIOLOGY, 1991, 178 (02) : 303 - 313
  • [8] Helical CT angiography for examination of living renal donors
    Cochran, ST
    Krasny, RM
    Danovitch, GM
    Rajfer, J
    Barbaric, ZM
    Wilkinson, A
    Rosenthal, JT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) : 1569 - 1573
  • [9] SPIRAL CT ANGIOGRAPHY
    DILLON, EH
    VANLEEUWEN, MS
    FERNANDEZ, MA
    MALI, WPTM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) : 1273 - 1278
  • [10] Spiral CT angiography in the assessment of abdominal aortic aneurysms after stent grafting: Value of maximum intensity projections
    Dorffner, R
    Thurnher, S
    Youssefzadeh, S
    Winkelbauer, F
    Holzenbein, T
    Polterauer, P
    Lammer, J
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (03) : 472 - 477