TECHNICAL OPTIMIZATION OF SPIRAL CT FOR DEPICTION OF RENAL-ARTERY STENOSIS - IN-VITRO ANALYSIS

被引:96
作者
BRINK, JA
LIM, JT
WANG, G
HEIKEN, JP
DEYOE, LA
VANNIER, MW
机构
[1] Department of Radiology, Mallinckrodt Institute of Radiology, Washington Univ. School of Medicine, St Louis, MO 63110
关键词
COMPUTED TOMOGRAPHY (CT); HELICAL; RENAL ARTERIES; STENOSIS OR OBSTRUCTION;
D O I
10.1148/radiology.194.1.7997544
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine empirically the effect of scan parameters and postprocessing techniques on depiction accuracy of renal artery stenosis with spiral computed tomographic angiography. MATERIALS AND METHODS: Critical(85%) and noncritical (45%) stenoses in the coronal plane were modeled in vitro and scanned with 12 combinations of collimation (1, 2, or 3 mm), table increment (pitch = 1-2),2 and reconstruction interval (0.5 or 1.0 mm). Five test images were generated for each spiral scanning technique: multiplanar reformation (MPR), maximum-intensity projections (MIPs: coronal MIP [MIPcor], coronal MIP targeted to phantom vessel and surrounding fat [target MIPcor]), transaxial imaging, and transaxial MIP. RESULTS: With 3-mm collimation, critical stenosis was overestimated to the point of occlusion on MIPcor images and underestimated on MPR and target MIPcor images. A 0.5-mm reconstruction interval was marginally beneficial for 1- and 2-mm collimation, but noise was prohibitive with 1-mm collimation. CONCLUSION: Critical renal artery stenosis is best depicted with 2-mm collimation, 2-4-mm table increment, and 1-mm reconstruction interval.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 14 条
  • [1] ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS
    ANDERSON, CM
    SALONER, D
    TSURUDA, JS
    SHAPEERO, LG
    LEE, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) : 623 - 629
  • [2] SPIRAL CT - DECREASED SPATIAL-RESOLUTION INVIVO DUE TO BROADENING OF SECTION-SENSITIVITY PROFILE
    BRINK, JA
    HEIKEN, JP
    BALFE, DM
    SAGEL, SS
    DICROCE, J
    VANNIER, MW
    [J]. RADIOLOGY, 1992, 185 (02) : 469 - 474
  • [3] CONTRAST-TO-NOISE RATIOS IN MAXIMUM INTENSITY PROJECTION IMAGES
    BROWN, DG
    RIEDERER, SJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) : 130 - 137
  • [4] VOLUME RENDERING AND CONNECTIVITY ALGORITHMS FOR MR ANGIOGRAPHY
    CLINE, HE
    DUMOULIN, CL
    LORENSEN, WE
    SOUZA, SP
    ADAMS, WJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) : 384 - 394
  • [5] NEWER TESTS FOR THE DIAGNOSIS OF RENOVASCULAR DISEASE
    DAVIDSON, RA
    WILCOX, CS
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 268 (23): : 3353 - 3358
  • [6] CT ANGIOGRAPHY - APPLICATION TO THE EVALUATION OF CAROTID-ARTERY STENOSIS
    DILLON, EH
    VANLEEUWEN, MS
    FERNANDEZ, MA
    EIKELBOOM, BC
    MALI, WPTM
    [J]. RADIOLOGY, 1993, 189 (01) : 211 - 219
  • [7] RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY
    GALANSKI, M
    PROKOP, M
    CHAVAN, A
    SCHAEFER, CM
    JANDELEIT, K
    NISCHELSKY, JE
    [J]. RADIOLOGY, 1993, 189 (01) : 185 - 192
  • [8] LUMEN DEFINITION IN MR ANGIOGRAPHY
    LIN, WL
    HAACKE, EM
    SMITH, AS
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03): : 327 - 336
  • [9] EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT
    POLACIN, A
    KALENDER, WA
    MARCHAL, G
    [J]. RADIOLOGY, 1992, 185 (01) : 29 - 35
  • [10] 3-DIMENSIONAL SPIRAL CT ANGIOGRAPHY OF THE ABDOMEN - INITIAL CLINICAL-EXPERIENCE
    RUBIN, GD
    DAKE, MD
    NAPEL, SA
    MCDONNELL, CH
    JEFFREY, RB
    [J]. RADIOLOGY, 1993, 186 (01) : 147 - 152