Validity of fan-beam dual-energy X-ray absorptiometry for measuring fat-free mass and leg muscle mass

被引:345
作者
Visser, M
Fuerst, T
Lang, T
Salamone, L
Harris, TB
机构
[1] Vrije Univ Amsterdam, Inst Res Extramural Med, Fac Med, NL-1081 BT Amsterdam, Netherlands
[2] NIA, Epidemiol Demog & Biometry Program, Bethesda, MD 20892 USA
[3] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94105 USA
[4] Univ Pittsburgh, Dept Epidemiol, Pittsburgh, PA 15261 USA
关键词
computed tomography; elderly; multicompartment models;
D O I
10.1152/jappl.1999.87.4.1513
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The aim of the study was to examine the accuracy of fan-beam dual-energy X-ray absorptiometry (DEXA) for measuring total body fat-free mass (FFM) and leg muscle mass (MM) in elderly persons. Participants were 60 men and women aged 70-79 yr and with a body mass index of 17.5-39.8 kg/m(2). FFM and MM at four leg regions were measured by using DEXA (Hologic 4500A, v8.21). A four-compartment body composition model (4C) and multislice computed tomography (CT) of the legs were used as the criterion methods for FFM and MM, respectively. FFM by DEXA was positively associated with FFM by 4C (R(2) = 0.98, SE of estimate = 1.6 kg). FFM. by DEXA. was higher [53.5 +/- 12.0 (SD) kg] than FFM by 4C (51.6 +/- 11.9 kg; P < 0.001). No association was observed between the difference and the mean of the two methods. MM. by DEXA was positively associated with CT at all four leg regions (R(2) = 0.86-0.96). MM by DEXA was higher than by CT in three regions. The results of this study suggest that fan-beam DEXA offers considerable promise for the measurement of total body FFM and leg MM in elderly persons.
引用
收藏
页码:1513 / 1520
页数:8
相关论文
共 18 条
[1]  
Armellini F, 1996, INT J OBESITY, V20, P37
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
CHOWDHURY B, 1994, INT J OBESITY, V18, P219
[4]   Body composition by DEXA in older adults: Accuracy and influence of scan mode [J].
Clasey, JL ;
Hartman, ML ;
Kanaley, J ;
Wideman, L ;
Teates, CD ;
Bouchard, C ;
Weltman, A .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1997, 29 (04) :560-567
[5]   ASSESSMENT OF THE COMPOSITION OF MAJOR BODY REGIONS BY DUAL-ENERGY X-RAY ABSORPTIOMETRY (DEXA), WITH SPECIAL REFERENCE TO LIMB MUSCLE MASS [J].
FULLER, NJ ;
LASKEY, MA ;
ELIA, M .
CLINICAL PHYSIOLOGY, 1992, 12 (03) :253-266
[6]   VALIDATION OF BODY-COMPOSITION BY DUAL ENERGY X-RAY ABSORPTIOMETRY (DEXA) [J].
HAARBO, J ;
GOTFREDSEN, A ;
HASSAGER, C ;
CHRISTIANSEN, C .
CLINICAL PHYSIOLOGY, 1991, 11 (04) :331-341
[7]   APPENDICULAR SKELETAL-MUSCLE MASS - MEASUREMENT BY DUAL-PHOTON ABSORPTIOMETRY [J].
HEYMSFIELD, SB ;
SMITH, R ;
AULET, M ;
BENSEN, B ;
LICHTMAN, S ;
WANG, J ;
PIERSON, RN .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 52 (02) :214-218
[8]  
KVIST H, 1986, INT J OBESITY, V10, P53
[9]  
LOHMAN TG, 1993, BASIC LIFE SCI, P53
[10]  
MARTIN AD, 1994, INT J OBESITY, V18, P79