Almost perfect concordance between simultaneous transcranial Doppler and transesophageal echocardiography in the quantification of right-to-left shunts

被引:81
作者
Belvís, R
Leta, RG
Martí-Fàbregas, J
Cocho, D
Carreras, F
Pons-Lladó, G
Martí-Vilalta, JL
机构
[1] Univ Autonoma Barcelona, Hosp Santa Creu & St Pau, Dept Neurol, Stroke Unit, E-08025 Barcelona, Spain
[2] Univ Autonoma Barcelona, Hosp Santa Creu & St Pau, Dept Cardiol, Cardiac Imaging Unit, E-08025 Barcelona, Spain
关键词
transcranial Doppler; patent foramen ovale; transesophageal echocardiography; stroke;
D O I
10.1111/j.1552-6569.2006.00021.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose. Transesophageal echocardiography (TEE) and transcranial Doppler (TCD) are the methods of choice to study patent foramen ovale (PFO), but there are discrepancies between the 2 concerning PFO detection. No study has analyzed right-to-left shunt (RLS) quantification concordance. The 2 methods are carried out in different hemodynamic states, and the Valsalva maneuver (VM) required in each also differs. The authors compared PFO detection and concordance of RLS quantification classifications performing the 2 studies simultaneously. Methods. The authors prospectively included consecutive stroke patients undergoing TEE and applied the TCD protocol of the Consensus Conference. Echocardiographic PFO was diagnosed when at least 3 microbubbles (MBs) were detected in the left atrium within 3 heartbeats after opacification of the right atrium. RLS quantification was (1) TCD: minimum (1-10 MBs), moderate (11-25 MBs), and massive (> 25 MBs) and (2) TEE: small (3-10 MBs), moderate (11-30 MBs), and large (> 30 MBs). Statistics: contingency tables (chi(2) and K test). Results. The authors studied 110 patients whose mean age was 56.7 +/- 12.1 years, and 60.9% were men. PFO was detected at the first VM in 30% of patients with TCD and in 31.8% with TEE. At the second VM, both methods detected the same patients (32.7%). RLS was minimum (14), moderate (5), and massive (17) in TCD and small (13), moderate (3), and large (20) in TEE. There was an almost perfect concordance in RLS quantification (K = 0.928, P= .001), with only 4 discrepancies. Conclusions. Simultaneous study with TCD and TEE showed an almost perfect concordance in PFO detection and RLS quantification.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 40 条
[1]   CLASSIFICATION OF SUBTYPE OF ACUTE ISCHEMIC STROKE - DEFINITIONS FOR USE IN A MULTICENTER CLINICAL-TRIAL [J].
ADAMS, HP ;
BENDIXEN, BH ;
KAPPELLE, LJ ;
BILLER, J ;
LOVE, BB ;
GORDON, DL ;
MARSH, EE ;
KASE, CS ;
WOLF, PA ;
BABIKIAN, VL ;
LICATAGEHR, EE ;
ALLEN, N ;
BRASS, LM ;
FAYAD, PB ;
PAVALKIS, FJ ;
WEINBERGER, JM ;
TUHRIM, S ;
RUDOLPH, SH ;
HOROWITZ, DR ;
BITTON, A ;
MOHR, JP ;
SACCO, RL ;
CLAVIJO, M ;
ROSENBAUM, DM ;
SPARR, SA ;
KATZ, P ;
KLONOWSKI, E ;
CULEBRAS, A ;
CAREY, G ;
MARTIR, NI ;
FICARRA, C ;
HOGAN, EL ;
CARTER, T ;
GURECKI, P ;
MUNTZ, BK ;
RAMIREZLASSEPAS, M ;
TULLOCH, JW ;
QUINONES, MR ;
MENDEZ, M ;
ZHANG, SM ;
ALA, T ;
JOHNSTON, KC ;
ANDERSON, DC ;
TARREL, RM ;
NANCE, MA ;
BUDLIE, SR ;
DIERICH, M ;
HELGASON, CM ;
HIER, DB ;
SHAPIRO, RA .
STROKE, 1993, 24 (01) :35-41
[2]   VALIDATION OF TRANSCRANIAL DOPPLER SONOGRAPHY IN THE ASSESSMENT OF PATENT FORAMEN OVALE [J].
ANZOLA, GP ;
RENALDINI, E ;
MAGONI, M ;
COSTA, A ;
COBELLI, M ;
GUINDANI, M .
CEREBROVASCULAR DISEASES, 1995, 5 (03) :194-198
[3]   Transcranial Doppler: Cinderella in the assessment of patent foramen ovale in stroke patients [J].
Anzola, GP .
STROKE, 2004, 35 (06) :E137-E137
[4]   Transcranial Doppler and risk of recurrence in patients with stroke and patent foramen ovale [J].
Anzola, GP ;
Zavarize, P ;
Morandi, E ;
Rozzini, L ;
Parrinello, G .
EUROPEAN JOURNAL OF NEUROLOGY, 2003, 10 (02) :129-135
[5]   Significant association of atrial vulnerability with atrial septal abnormalities in young patients with ischemic stroke of unknown cause [J].
Berthet, K ;
Lavergne, T ;
Cohen, A ;
Guize, L ;
Bousser, MG ;
Le Heuzey, JY ;
Amarenco, P .
STROKE, 2000, 31 (02) :398-403
[6]   ATRIAL SEPTAL ANEURYSM AND PATENT FORAMEN OVALE AS RISK-FACTORS FOR CRYPTOGENIC STROKE IN PATIENTS LESS-THAN 55 YEARS OF AGE - A STUDY USING TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
CABANES, L ;
MAS, JL ;
COHEN, A ;
AMARENCO, P ;
CABANES, PA ;
OUBARY, P ;
CHEDRU, F ;
GUERIN, F ;
BOUSSER, MG ;
DERECONDO, J .
STROKE, 1993, 24 (12) :1865-1873
[7]   Interobserver and intraobserver variability in detection of patent foramen ovale and atrial septal aneurysm with transesophageal echocardiography [J].
Cabanes, L ;
Coste, J ;
Derumeaux, G ;
Jeanrenaud, X ;
Lamy, C ;
Zuber, M ;
Mas, JL .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (05) :441-446
[8]   TRANSCRANIAL DOPPLER ULTRASOUND IDENTIFIES PATIENTS WITH RIGHT-TO-LEFT CARDIAC OR PULMONARY SHUNTS [J].
CHIMOWITZ, MI ;
NEMEC, JJ ;
MARWICK, TH ;
LORIG, RJ ;
FURLAN, AJ ;
SALCEDO, EE .
NEUROLOGY, 1991, 41 (12) :1902-1904
[9]  
CONHEIM J, 1877, THROMBOSE EMBOLIE VO, P134
[10]   Morphological and functional characteristics of patent foramen ovale and their embolic implications [J].
De Castro, S ;
Cartoni, D ;
Fiorelli, M ;
Rasura, M ;
Anzini, A ;
Zanette, EM ;
Beccia, M ;
Colonnese, C ;
Fedele, F ;
Fieschi, C ;
Pandian, NG .
STROKE, 2000, 31 (10) :2407-2413